A brake is easy to overlook until it fails — and then the result is a runaway load or one that creeps downhill. The first thing an experienced engineer tells a trainee is usually: work out the brake torque first, worry about motor power later. Two field failures recur. The first is sizing the brake to the motor nameplate torque, forgetting that what pushes the load once the power is cut is inertia, not the motor. The second is finding on a vertical lift that the holding torque is one step short — the platform drifts down half a turn the moment the contactor opens.
When brake torque comes out wrong, the usual missing entries are:
The rest of this article covers three load types, one criterion and two worked examples.
The selection process rests on one inequality: the load torque reflected to the brake shaft, times the service factor, must not exceed the brake's rated static torque.
| Parameter | Meaning | Unit | Notes |
|---|---|---|---|
| Te | Equivalent load torque reflected to the brake shaft | N·m | Inertia term plus resistance term |
| J | Rotational inertia reflected to the brake shaft | kg·m² | Use J/i² when reflecting from a high-speed shaft |
| ω | Angular velocity of the brake shaft | rad/s | ω = 2πn/60 |
| tb | Braking time | s | From the stop command to full standstill, not the pull-in time |
| Tf | Friction / resistance torque | N·m | Guideway friction, seal drag, material resistance |
| m | Lifted mass | kg | Including platform, fixture and payload |
| r | Load radius of the drum or gear | m | Taken as the lever arm |
| i | Transmission ratio from motor to drum | — | Reduction ratio |
| K | Service factor | — | See the table below |
| Tb | Rated static torque of the brake | N·m | Catalogue value |
Service factor K:
| Duty condition | K |
|---|---|
| Horizontal conveying, normal stopping | 1.5–1.8 |
| Frequent inching, high start/stop rate | 2.0–2.5 |
| Vertical lifting, load must be held with power off | 2.0–2.5 |
Example A — Conveyor line stop (horizontal inertial load)
Given: drive drum diameter D = 200 mm (r = 0.1 m), rotational inertia reflected to the drum shaft J = 2.5 kg·m², drum speed before stopping n = 60 r/min, required stopping time tb = 0.5 s, friction resistance torque from guideways and material Tf = 8 N·m, service factor K = 1.8.
Step 1: Angular velocity. ω = 2πn/60 = 2π×60/60 = 6.283 rad/s.
Step 2: Inertial torque. Ta = J·ω/tb = 2.5×6.283/0.5 = 31.4 N·m.
Step 3: Equivalent load torque. Te = Ta + Tf = 31.4 + 8 = 39.4 N·m.
Step 4: Apply the criterion. Tb ≥ K·Te = 1.8×39.4 = 70.9 N·m — choose the size with a rated static torque of 80 N·m or more.
Step 5: Check the braking distance. θ = ω·tb/2 = 6.283×0.5/2 = 1.571 rad, s = θ·r = 1.571×0.1 = 0.157 m ≈ 157 mm.
Result: brake rated static torque 80 N·m; the conveyor coasts about 157 mm during a full-load stop.
Example B — Lift anti-fall (vertical load)
Given: lifted mass m = 500 kg (platform plus workpiece), drum radius r = 0.15 m, reduction ratio i = 40, friction neglected, K = 2.0 (load must be held with power off).
Step 1: Gravity torque. m·g·r = 500×9.81×0.15 = 735.8 N·m.
Step 2: Reflect to the brake shaft. Te = 735.8/40 = 18.4 N·m.
Step 3: Apply the criterion. Tb ≥ 2.0×18.4 = 36.8 N·m — choose the 40 N·m size.
Result: if the customer also requires no creep-down after power is cut, raise K to 2.5, giving Tb ≥ 2.5×18.4 = 46.0 N·m, so pick the 50 N·m size. Mounting the brake on the motor shaft (high-speed side) gives the smallest torque and the cheapest structure, but check the permissible speed.