The parallel key is the cheapest connection and the one whose check is skipped most often. What the shop calls a rolled key is usually not a key cut cleanly in two — it is the crushing surface between key and keyway collapsing, the key rounding over in the slot, the clearance growing, the impact getting harsher, and finally key and keyway scrapped together.
Failures of this kind almost always happen on shafts where the crushing check was never done: a diameter was given from experience, a key was picked from the standard, nobody computed σp, and then the key was too short or the hub was cast iron, and a heavy load crushed it flat.
Three things have to be watched when checking a parallel key:
| Parameter | Meaning | Unit | Notes |
|---|---|---|---|
| T | Transmitted torque | N·mm | Take the working torque |
| d | Shaft diameter | mm | Diameter at the key location |
| b | Key width | mm | Selected by shaft diameter per GB/T 1095/1096 |
| h | Key height | mm | The crushing surface enters the formula as h/2 |
| l | Working length of the key | mm | Round-ended l = L − b, square-ended l = L |
| L | Nominal length of the key | mm | Taken from the standard length series |
| [σp] | Allowable crushing stress | MPa | From the table, by duty condition and hub material |
| [τ] | Allowable shear stress | MPa | Typically around 60 MPa |
Allowable crushing stress [σp] (typical ranges; the handbook or the manufacturer takes precedence):
| Duty condition | [σp] / MPa |
|---|---|
| Static connection, steady load (steel hub) | 120–150 |
| Static connection, mild shock | 100–120 |
| Static connection, shock load or cast-iron hub | 60–90 |
| Moving connection (guide key, sliding key) | 50–60 |
Given: pulley mounted on a motor shaft, shaft diameter d = 45 mm, transmitted torque T = 200 N·m, Type A parallel key 14×9×50 (GB/T 1096, key width b = 14, key height h = 9, nominal length L = 50), steel hub, mild shock, [σp] = 100 MPa, [τ] = 60 MPa.
Step 1: Working length. Round-ended key l = L − b = 50 − 14 = 36 mm.
Step 2: Crushing check. σp = 4T/(d·h·l) = 4×200,000/(45×9×36) = 800,000/14,580 = 54.9 MPa ≤ 100 MPa.
Step 3: Shear check. τ = 2T/(d·b·l) = 2×200,000/(45×14×36) = 400,000/22,680 = 17.6 MPa ≤ 60 MPa.
Step 4: Compare key types. With a Type B square-ended key of the same L = 50, l = 50 and σp = 4×200,000/(45×9×50) = 39.5 MPa, 28 % lower than the round-ended key. With two keys at 180°, counting 1.5 times the capacity, σp = 4×200,000/(45×9×36×1.5) = 36.6 MPa.
Result: both the crushing and the shear stress pass, with roughly 1.8 times margin. A single Type A key 14×9×50 is enough for this duty; reserve two keys for reversing duty, high shock or where reliability has to be raised.