A screw jack (worm-gear screw jack) is the standard solution for heavy, slow, accurate straight-line lifting — cranes, lift tables, gates and solar trackers all use it. Its three main assemblies are the worm gear pair, the screw-and-nut set, and the housing. The real question in selection is not "will it lift the load", but three things together: is the drive torque sufficient, will it hold the load when stationary (self-locking), and will the slender screw buckle?
On site the failures usually come from the last two: the torque was sized correctly, but the platform ran down on its own after the power was cut; or the screw was too long, buckled under compression, and the whole unit failed. These three accounts have to be settled together.
Selection goes wrong when:
| Parameter | Meaning | Unit | Notes |
|---|---|---|---|
| F | axial load | N | lifting / lowering load |
| Ph | thread lead | mm | Ph = 7 for Tr40×7 |
| d2 | thread pitch diameter | mm | taken from the standard |
| λ | thread lead angle | ° | — |
| μv | screw pair friction coefficient | — | steel on bronze 0.08–0.1 |
| β/2 | trapezoidal thread flank half-angle | ° | typically 15° |
| ρv | equivalent friction angle | ° | — |
| η | drive efficiency | — | 0.3–0.4 is typical |
| d3 | thread minor diameter | mm | critical section for buckling |
| E | modulus of elasticity | MPa | 2.06×10⁵ for steel |
| I | section moment of inertia | mm⁴ | πd3⁴/64 |
| μ | length factor | — | 1 pinned-pinned, 2 fixed-free |
| l | compressed screw length | mm | per the actual stroke |
Given: a screw jack lifting a 30 kN load, initially a trapezoidal screw Tr40×7 (lead Ph = 7 mm, pitch diameter d2 = 36.5 mm, minor diameter d3 = 31.5 mm), screw pair friction coefficient μv = 0.1, flank half-angle β/2 = 15°, compressed length l = 1500 mm, supported fixed at one end and free at the other (μ = 2).
Step 1 — Lead angle. λ = arctan[Ph/(π·d2)] = arctan[7/(3.1416×36.5)] = arctan(0.06106) = 3.49°.
Step 2 — Equivalent friction angle. ρv = arctan[μv/cos(β/2)] = arctan[0.1/cos15°] = arctan(0.1/0.9659) = arctan(0.10353) = 5.91°.
Step 3 — Self-locking and efficiency. λ = 3.49° ≤ ρv = 5.91°, so self-locking holds; η = tanλ/tan(λ+ρv) = tan3.49°/tan(9.40°) = 0.06098/0.16552 = 0.369.
Step 4 — Drive torque. T = F·Ph/(2π·η) = 30000×0.007/(2π×0.369) = 210/2.3185 = 90.6 N·m.
Step 5 — Buckling check. I = π·d3⁴/64 = 3.1416×31.5⁴/64 = 48 329 mm⁴; Fcr = π²·E·I/(μl)² = 9.8696×2.06×10⁵×48329/(2×1500)² = 10 918 N ≈ 10.9 kN; n = Fcr/F = 10918/30000 = 0.36 < 2.5, so it fails.
Step 6 — Change the size and recalculate. Switching to Tr60×9 (d2 = 55.5, d3 = 50 mm, I = π×50⁴/64 = 306 796 mm⁴) gives λ = arctan(9/(π×55.5)) = 2.96°, η = tan2.96°/tan(8.87°) = 0.331, T = 30000×0.009/(2π×0.331) = 129.8 N·m; Fcr = 9.8696×2.06×10⁵×306796/(3000)² = 69.3 kN, n = 2.31 (still on the low side). If the compressed length is shortened to 1000 mm, Fcr = 9.8696×2.06×10⁵×306796/(2000)² = 156 kN, n = 5.2, which passes.
Result: Tr40×7 self-locks and needs 90.6 N·m of drive torque, but with a compressed length of 1500 mm its critical load is only 10.9 kN, so it fails the stability check. Engineering options: (1) move up to Tr60×9, where n rises to 2.31 — still marginal; (2) add an intermediate support or guide to cut the compressed length to 1000 mm, where n reaches 5.2 and passes. The combined answer: Tr60×9 with a shortened compressed length (or a heavier guide), and size the worm gear pair and motor from 129.8 N·m at the drive end.