1. Guess the shaft diameter wrong and everything downstream fails to line up

Experienced engineers have a saying: estimate the diameter first, verify later. The first diameter on a drawing is rarely the result of a full calculation — it comes from torsional strength. The shaft has a keyway, shoulders and a bearing bore to match, so you need a diameter before you can lay out the structure and look up standard parts.

Beginners usually go to one of two extremes: copying a competitor's shaft diameter even though the power and speed are completely different, or skipping the estimate and going straight into combined bending and torsion, then getting stuck before the bending moment diagram is even drawn.

The estimate does three things:

2. Formulas and parameters

Estimation criterion: d ≥ A·(P/n)^(1/3)
Coefficient source: A = (47.75×10⁶/[τ]T)^(1/3)
Check formula: τ = T/(0.2·d³) ≤ [τ]T
Design torque: T = 9550×10³·P/n (N·mm)
ParameterMeaningUnitNotes
dMinimum shaft diametermmAt the critical section, usually where the coupling or pulley sits
PTransmitted powerkWUse the working power, not the motor rated power
nOperating shaft speedr/minMust belong to the same duty point as P
ACalculation coefficient—From the table, allowing for the bending effect
[τ]TAllowable torsional shear stressMPaTypically 25–45 for 45 steel
TDesign torqueN·mmT = 9550×10³P/n
0.2d³Torsional section modulus Wtmm³For a solid round shaft πd³/16 ≈ 0.2d³

A-value table (derived from A = (47.75×10⁶/[τ]T)^(1/3), matching the common values in machine design handbooks):

Shaft material[τ]T / MPaA
Q235A, 20 steel12–20160–135
35 steel20–30135–118
45 steel25–45126–103
40Cr, 35SiMn, 38SiMnMo35–55112–97

How to pick A: for the same material, a small A gives a small diameter, higher stress, lower cost and higher risk. Where there is bending, a keyway, impact loading or a cast-iron part, take the larger value. Only pure torsion with negligible bending justifies the lower limit.

💡 Practical tip:One keyway adds 3 %–5 % to the shaft diameter; two keyways at 180° add 7 %–10 %. Add this weakening back in at the estimation stage.
💡 Practical tip:Round the estimated diameter up to the standard shaft series (…38, 40, 42, 45, 48, 50…) and make sure it matches the bore of the bearing you selected, otherwise the structure will have to be reworked.
⚠️ Caution:The estimate only guarantees torsional strength, not bending or fatigue strength. When the shaft carries a large bending moment from an overhung pulley or an offset gear, the combined bending and torsion check must follow — the initial value is a starting point, not the answer.

3. Worked example

Given: gearbox output shaft, transmitted power P = 7.5 kW, output speed n = 145 r/min, quenched and tempered 45 steel, A = 110 (the shaft has a keyway and an overhung pulley, so the bending influence is large and the conservative value is taken).

Step 1: Coefficient term. P/n = 7.5/145 = 0.05172, (0.05172)^(1/3) = 0.3726.

Step 2: Estimated diameter. d ≥ 110×0.3726 = 41.0 mm.

Step 3: Add the keyway allowance. One keyway, +4 %: 41.0×1.04 = 42.6 mm, rounded to the standard diameter d = 45 mm.

Step 4: Back-check. Design torque T = 9550×7.5/145 = 493.9 N·m = 493,970 N·mm; Wt = 0.2×45³ = 18,225 mm³; τ = 493,970/18,225 = 27.1 MPa ≤ [τ]T = 35 MPa (mid value for 45 steel).

Result: minimum shaft diameter 45 mm, torsional shear stress 27.1 MPa, roughly 1.3 times margin. The 45 mm also matches the bore of a 6309-type bearing, so the layout can carry on.

4. Common mistakes and cautions

📖 Next up:with the shaft diameter settled, the next part to check is the one most likely to let you down — the parallel key. See how σp = 4T/(d·h·l) checks crushing strength.