A key, a pin or a bolted clamp all transmit load the same way: a hard shoulder of material simply blocks the load path. An interference fit works on a different principle. The diametral oversize between the shaft and the bore generates a contact pressure at the mating surface; that pressure produces friction; the friction carries the torque. So when you qualify an interference joint, there is really only one question to answer: can the friction at the mating surface hold the external load?
A locking assembly (also sold as a shrink disc or keyless locking device) is the engineered, off-the-shelf version of the same idea. You tighten the clamping screws, the tapered surfaces expand the inner ring and compress the outer ring, and contact pressure builds up on the mating surface. It comes apart without heating, it does not damage the shaft, and it is widely used on couplings, gearbox hollow shafts and pulleys.
When the torque capacity comes out wrong, it is usually because one of these items was never accounted for:
The whole calculation rests on one relationship: the friction available at the interface must at least equal the load it has to carry. Torque capacity follows directly from that, and once a bending moment is present, the two load components are combined before the pressure is back-calculated.
| Parameter | Meaning | Unit | Notes |
|---|---|---|---|
| T | transmitted torque | N·mm | what the mating surface can carry |
| p | contact pressure at the interface | MPa | generated by the interference |
| d | mating diameter | mm | fit diameter of shaft and hub |
| l | mating length | mm | effective contact length |
| μ | friction coefficient at the interface | — | steel on steel 0.10–0.15 |
| Ft | peripheral (tangential) force | N | Ft = 2T/d |
| M | additional bending moment | N·mm | converted from external loads |
| FM | bending equivalent peripheral force | N | FM = 2M/d |
| p_eq | equivalent contact pressure | MPa | includes the bending contribution |
Given: a shaft-to-hub interference joint, mating diameter d = 80 mm, mating length l = 100 mm, friction coefficient μ = 0.15. It must transmit a torque T = 6000 N·m while also carrying a bending moment M = 2000 N·m.
Step 1 — Put everything into consistent units. T = 6000 N·m = 6×10⁶ N·mm, M = 2000 N·m = 2×10⁶ N·mm.
Step 2 — Contact pressure required for pure torque. p = 2T/(π·d²·l·μ) = 2×6×10⁶/(3.1416×80²×100×0.15) = 1.2×10⁷/301 593 = 39.8 MPa.
Step 3 — Peripheral force. Ft = 2T/d = 2×6×10⁶/80 = 150 000 N.
Step 4 — Bending equivalent force. FM = 2M/d = 2×2×10⁶/80 = 50 000 N.
Step 5 — Equivalent pressure. F_eq = √(Ft²+FM²) = √(150000²+50000²) = 158 114 N; p_eq = F_eq/(π·d·l·μ) = 158114/(3.1416×80×100×0.15) = 41.9 MPa.
Result: pure torque needs 39.8 MPa, and adding the 2000 N·m bending moment raises the equivalent pressure to 41.9 MPa — about 5.4% higher. Set the interference, or pick the locking assembly, from this pressure (choose a size rated for at least 6000 N·m of torque and able to resist 2000 N·m of bending), and leave further margin for temperature and repeated-dismantling losses.