Liquids tax photoelectric sensing three ways: clear liquids barely reflect, coloured liquids absorb hard, and the surface itself is a mirror. Each duty needs its own sensor type, tilt angle and sensitivity recipe.
For clear bottles use a retroreflective or thru-beam unit: light crosses the bottle and the arriving level shows up as a sharp refraction change, sensing the whole fill. On sight glasses a laser diffuse type aimed at the meniscus works well because wet glass reflects differently from dry. For coloured or opaque media, forget optical through-wall schemes and pair a thin steel or aluminium foil pad on the outer wall with a capacitive sensor, or use a magnetic float switch. Strongly absorbing liquids call for an 850nm near-infrared thru-beam type with generous optical margin.
Since the liquid surface is a natural mirror, aim diffuse units 10~15 degrees off the surface normal so the meniscus lobe reaches the receiver. Tune in order: adjust on the empty vessel until steadily off, fill to the target level until steadily on, then back the sensitivity off 20 percent. Mount the switch 2~3mm above the target level where level surges, so the rising surface does the triggering. Avoid foam zones, prefer fine-spot laser types where bubbles or wall film exist, choose modulated sensors with the receiver facing away from bright lights, and retune whenever the liquid recipe changes.
| Duty | Recommended scheme | Key adjustment |
|---|---|---|
| Clear bottle, whole level | Retroreflective or thru-beam | Detect refraction change through wall |
| Sight-glass level | Laser diffuse, 10~15 degree tilt | Spot on the meniscus |
| Coloured or opaque liquid | Foil pad on wall plus capacitive | No optical through-wall needed |
| Strongly absorbing liquid | 850nm near-infrared thru-beam | Large optical margin |
| Surging level | Switch 2~3mm above target | Rising surface triggers, 20% backoff |
| Foam or wall film | Fine-spot laser type | Aim away from bubble clusters |
Every change of liquid, bottle or ambient lighting invalidates the tuning, so log the empty value, the full value and the backoff for each setup. Bottle changes are the classic false-alarm source; making the bracket adjustable at design time saves half the commissioning time later.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Photoelectric detection characteristics per GB/T 14048.10 (IEC 60947-5-2); machine electrical safety per GB/T 5226.1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.