Linear scales fear contamination: coolant, dust and oil mist entering the scan unit cause drift at best and scrap at worst. Protection class, air-purge setup, cleaning discipline and inspection periods keep the accuracy alive.
Contaminants enter three ways: through aged wiper lips along the scale body, through wet or oily compressed air blown into the scan cavity, and from fingerprints left during fitting. Choose the class by duty: IP53 minimum in dry dust, IP64 and above under wet machining, fully sealed IP67-grade or air-curtain products under direct coolant spray. Air-purged scales demand clean, dry air - fit a water-oil separator and a sub-micron filter, because unconditioned shop air turns the purge into a contamination pump, the classic well-meant mistake on the floor.
Four purge parameters: pressure 0.05~0.1MPa, lower fails to clear coolant and higher disturbs the wiper; dew point at least 10 degrees below ambient to keep water out of the line; filtration to 5µm with oil-water separation; 6mm PU tubing kept short with quick-release fittings. Drain the filter daily, and weekly check the air pattern by sliding a paper strip along the scale - the flow should lift it evenly. Cleaning uses isopropyl or absolute ethanol on lint-free cloth, one-directional wipes, never acetone or ordinary rags - acetone attacks wipers and the grating protective layer; clean the head window the same way. Inspect monthly for lip condition (replace on curling or hardening), quarterly re-check the head gap with a dial gauge, and every six months compare accuracy against the installation record. Periodic drift with travel means contamination; random drift means interference or cable - split the hunt accordingly.
| Item | Standard or practice | Note |
|---|---|---|
| Protection class | IP53 dust, IP64 wet, IP67 spray | Pick one class above the worst duty |
| Air purge pressure | 0.05~0.1MPa | Too weak misses, too strong harms the wiper |
| Air quality | Dew point 10 degrees below ambient, 5µm filter | Untreated air becomes the pollutant |
| Cleaning agent | Absolute ethanol or IPA on lint-free cloth | No acetone, no ordinary rags |
| Wiper inspection | Monthly | Replace on curling or hardening |
| Accuracy spot check | Half-yearly against the archive | Periodic drift marks contamination |
Protection pays for itself: a purge and filtration kit costs a few hundred, a replacement scale costs ten thousand and days of downtime. Put the daily filter drain and the monthly wiper check onto the maintenance cards, and give critical machines an annual scale overhaul - time spent buys years of accuracy.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Protection of position feedback devices per GB/T 5226.1 (IEC 60204-1) and related machine-guarding standards. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.