1. E3Z (built-in amplifier, most common)
Thread M8/M12
Detection method: through-beam / retro-reflective / diffuse reflective
Detection distance: 1 m / 3 m / 15 m
Response time: 1 ms
2. E3F (separate amplifier)
Long distance
Fiber type
3. E3X (fiber amplifier)
High precision
Tiny objects
4. E3C (laser)
Long distance
Precise
Model | Detection method | Detection distance | Interface | Output
E3Z-D61 | Diffuse reflective | 1 m | M8 | NPN
E3Z-D62 | Diffuse reflective | 1 m | M8 | PNP
E3Z-R61 | Retro-reflective | 2 m | M8 | NPN
E3Z-T81 | Through-beam | 15m | M8 | NPN
E3Z-LS61 | Limited-distance reflective | 1m | M8 | NPN
1. Through-beam type (opposed mode)
Separate emitter and receiver units
Triggered when an object blocks the beam
Pros: long distance, reliable
Cons: wiring required at both ends
Suitable for: large objects, long distance, high reliability
2. Retroreflective type
Emitter and receiver in one unit + reflector
Triggered when an object blocks the reflected light
Pros: wiring at only one end
Cons: moderate distance
Suitable for: general detection
3. Diffuse-reflective type
Combined emitter/receiver
Triggered by light reflected from the object's surface
Pros: no reflector needed
Cons: affected by object color/surface
Suitable for: small objects, irregular objects
4. Limited-distance reflective type
Precisely limits the detection distance
Eliminates background interference
Suitable for: edge detection / thickness
1. NPN (source type)
24V sink in
Suitable for Japanese / Chinese equipment
2. PNP (sink type)
24V output
Suitable for European equipment
3. Relay
Contact output
Suitable for high current
1. M8/M12 plug-in connector
Quick connection
Standardized
Suitable for batch
2. Direct-wired cable
2 m / 5 m cable
Economical
1. Determine the object to be detected
- Size / shape / color / material
- Transparent / opaque
- Surface finish
2. Determine the detection distance
3. Choose the detection method
- Through-beam: long distance / reliable
- Retroreflective: general purpose
- Diffuse-reflective: no reflector
4. Choose the output type
- Match the PLC input
- NPN/PNP
5. Select interface
- M8/M12 connector
- Lead wire
6. Protection class
- IP65 (splash-proof)
- IP67 (temporary immersion)
7. Operating environment
- Temperature
- Vibration
- Electromagnetic interference
Requirement: detect boxes on a conveyor (50×50×30 cm) at a distance of 1 m
1. Choose the diffuse-reflective E3Z-D61
Distance 1 m
The boxes are large, so reflection is sufficient
2. Output
The PLC is sink type, so choose PNP
E3Z-D62
3. Interface
M8 connector
4. Protection
IP67
1. Avoid direct strong light (incandescent lamps / sunlight)
2. Avoid mutual interference (side-by-side mounting >50 mm)
3. Align the reflector (retroreflective)
4. Keep the object surface clean
5. Reinforce the mounting where vibration occurs
6. Wire correctly (NPN / PNP)
1. Laser displacement sensor (high precision)
a. IL series (confocal)
Resolution 0.01 μm
Distance 0.5~30 mm
Accuracy ±0.1 μm
Suitable for: semiconductors / precision work
b. LR-Z series (triangulation)
Distance 20~500 mm
Resolution 1~10 μm
Suitable for: general
c. LR-T series (long distance)
Distance 0.1~5 m
Resolution 0.1 mm
Suitable for: level / distance
2. Inductive displacement sensor
a. EX-V series
Resolution 0.5 μm
Distance 0~2 mm
Suitable for: metal part measurement
b. GT2 series (contact type)
Resolution 0.5 μm
Measuring range 10~50 mm
Suitable for: in-line measurement
3. Ultrasonic displacement
a. UD series
Distance 30~6000 mm
Resolution 0.1~3 mm
Suitable for: transparent objects / liquid level
1. Triangulation method
Laser obliquely hits object
The receiver (CCD/PSD) forms an image at different positions
Distance → image position
High accuracy, short distance
2. Confocal method
Wavelength dispersion
Different distances correspond to different wavelengths
Extremely high accuracy, short distance
3. Time of flight (TOF)
Measure light round-trip time
Long distance, medium accuracy
1. CV-X series (high-speed, general purpose)
Camera: 21 MP
Processing speed: high
Programming: simple (flowchart-based)
Suitable for: general inspection
2. XG-X series (high precision)
Camera: 25 MP
21 inspection tools
Suitable for: complex inspection
3. IV2 series (smart camera)
Built-in processing
Compact
Simple inspection
1. Dimensional measurement
Length / width / angle / circle diameter
Accuracy 1~10 μm
2. Defect detection
Scratches / chips / stains
Edge / corner
3. Character recognition (OCR/OCV)
Printed characters
Serial number
Barcode / QR code
4. Pattern matching
Shape recognition
Counting
Locating
5. Color inspection
Color difference
Color mark
6. 3D measurement (optional)
Height
Volume
Shape
1. Area-scan camera
2D image
General purpose
Resolution: 0.3 MP~25 MP
2. Line-scan camera
Continuous scanning
Suitable for: web material / high speed
Resolution: 1K~16K
3. 3D camera
Stereo vision
Structured light
TOF
1. Field of view (FOV)
Must be larger than the object size
FOV = working distance × sensor size / focal length
2. Accuracy
Accuracy = FOV / number of pixels
Example: FOV=100 mm, 1024 pixels
Accuracy = 100/1024 = 0.1 mm
3. Working distance
4. Frame rate
Static: 10~30 fps
Dynamic: 60~1000 fps
5. Interface
GigE (most commonly used)
USB3.0
CameraLink
6. Lighting
Ring / bar / coaxial / backlight
Contrast
1. Dimensional measurement (accuracy 0.01 mm)
2. Surface defects (scratches / stains)
3. Assembly inspection (missing / wrong parts)
4. Character recognition (printed / coded)
5. Barcodes / 2D codes
6. Robot guidance (positioning)
7. Color sorting
8. Counting
Requirement: inspect parts 0~20 mm, accuracy 0.01 mm
1. Accuracy requirement
Accuracy = FOV / pixels
0.01mm×1024=10.24mm FOV
Choose FOV=20 mm, 2048 pixels
Accuracy = 20/2048 = 0.0098 mm ✓
2. Camera
5 megapixels (2592×1944)
FOV 20mm
3. Lens
Telecentric lens (eliminates perspective)
Magnification 0.1X
4. Lighting
Backlight (clear outline)
5. System
CV-X series
1. Thermocouple (TC)
Principle: a temperature difference at the junction of two metals generates a voltage
Measurement: -200~1800℃
Accuracy: ±1~5℃
Response: fast
2. Resistance temperature detector (RTD)
Principle: metal resistance varies with temperature
PT100: 0℃=100Ω, α=0.00385
PT1000: 0℃=1000Ω
Measurement: -200~600℃ (PT)
Accuracy: ±0.1~1℃
Response: medium
3. Thermistor (NTC/PTC)
Principle: semiconductor resistance varies with temperature
NTC: negative temperature coefficient
PTC: positive temperature coefficient
Measurement: -50~300℃
Accuracy: ±0.5~2℃
Response: fast
Low cost
4. Semiconductor temperature sensor
Principle: integrated circuit
LM35/DS18B20
Measurement: -55~150℃
Accuracy: ±0.5℃
Digital output
5. Infrared thermometer
Principle: measures infrared radiation
Non-contact
Measurement: -50~3000℃
Accuracy: ±1~2%
Type K (chromel-alumel): -200~1300℃, general purpose
Type J (iron-constantan): -40~750℃
Type T (copper-constantan): -200~350℃
Type E (chromel-constantan): -200~900℃
Type N (nicrosil-nisil): -200~1300℃
Type S (platinum-10% rhodium / platinum): 0~1600℃
Type R (platinum-13% rhodium / platinum): 0~1600℃
Type B (platinum-30% rhodium / platinum-6% rhodium): 600~1800℃
1. Two-wire
Lead resistance affects reading
Low accuracy
Suitable for short distance
2. Three-wire (most commonly used)
Lead compensation
Medium accuracy
Industrial standard
3. Four-wire
Fully eliminates leads
Highest accuracy
Laboratory / precision
1. Temperature range
-200~600℃: PT100
600~1300℃: Type K thermocouple
1300~1800℃: Type S/R/B
2. Accuracy
±0.1℃: PT100 (Class A)
±1℃: Type K thermocouple
±2℃: NTC
3. Response speed
Fast: thermocouples / NTC
Medium: RTD
Slow: RTDs with protective sleeves
4. Environment
Vibration: thermocouples are better
Corrosion: select material
High pressure: sheath
5. Distance
Short (<10 m): any type
Medium (10~100 m): three-wire PT100 / thermocouple
Long (>100 m): transmitter 4-20mA
6. Cost
Low: NTC / thermocouple
Medium: PT100
High: high-precision PT100 / Type S
1. Direct insertion (no thermowell)
Fast response
Not pressure resistant
Suitable for: air / atmospheric pressure
2. With thermowell
Protects sensor
Pressure resistant
Slow response
Suitable for: pipes / pressure vessels
3. Surface mounting
Measure surface temperature
Magnet / welding / adhesive
4. Embedded
Embedded in solid
Measure internal temperature
Requirement: measure the hydraulic oil tank temperature, 0~100℃, accuracy ±1℃
1. Choose PT100
Range suitable
Accuracy met
Good stability
2. Three-wire
Moderate distance
Compensate leads
3. With sheath
Oil environment
Easy to replace
4. Transmitter
4-20mA output
Transmit to PLC remotely
5. Installation
Tank side
Immersed in oil
Keep away from the return oil (high temperature)
Place near the pump suction (representative temperature)
1. Strain-gauge type
Elastic element + strain gauge
Accuracy 0.1~0.5%
General purpose
2. Piezoresistive type
Semiconductor diffusion
Accuracy 0.05~0.5%
Compact
3. Capacitive type
Capacitance change
Accuracy 0.05~0.1%
High precision
4. Piezoelectric type
Piezoelectric effect
Dynamic measurement
Cannot measure static pressure
5. Sapphire
High temperature
High precision
1. 4-20mA (most commonly used)
Two-wire
Interference resistant
Long distance
2. 0-10V/1-5V
Voltage
Short distance
3. RS485/Modbus
Digital
Multi-point
4. HART
Analog signal with superimposed digital data
5. PROFINET/IO-Link
Industrial Ethernet
Gauge pressure: relative to atmospheric pressure
Absolute pressure: relative to vacuum
Differential pressure: difference between two points
0.05%: high precision
0.1%: precision
0.25%: industrial standard
0.5%: general
1.0%: economy
1. Range
Normal operation at 30~70% of full scale
Maximum <90%
2. Medium
Gas / liquid
Corrosive
Temperature
3. Accuracy
4. Output signal
5. Process connection (thread / flange)
6. Protection class
7. Explosion-proof (hazardous environments)
1. Incremental
Outputs A/B/Z phase pulses
Loses position on power loss
Simple, economical
2. Absolute
Each position corresponds to a unique code
Retained on power loss
Multi-turn (battery / gear memory)
3. Optical
Grating disk + photoelectric detection
High resolution
Sensitive to contamination
4. Magnetic
Magnetic scale + Hall-effect detection
Environment resistant
Medium resolution
Incremental: 100~100000 pulses/rev
Absolute: 17bit (131072)~26bit (67108864)/rev
1. Incremental
- TTL/RS422 (differential, noise-immune)
- HTL (single-ended)
- Open collector
2. Absolute
- Parallel (Gray code)
- SSI (synchronous serial)
- BiSS (bidirectional)
- EnDat (Heidenhain)
- PROFINET/EtherCAT
1. Resolution
Positioning accuracy = 360° / resolution
17bit: 0.0028°
23bit: 0.000043°
2. Type
- Simple speed measurement: incremental
- Precise positioning: absolute
- Multi-turn: retains position after power loss
3. Interface
- Match the servo / PLC
- Communication protocol
4. Environment
- Vibration
- Contamination (photoelectric encoders are vulnerable)
- Magnetic field (EMI-sensitive)
5. Installation
- Shaft end (solid/hollow)
- Flange
- Coupling / direct
Heidenhain
Baumer
Renishaw
Omron
Nikon
1. Inductive (metal)
Detects metal
Distance 1–15 mm
No contact wear
Most common
2. Capacitive
Detects metal/non-metal
Distance 1–25 mm
Adjustable sensitivity
3. Magnetic (reed switch)
Detects magnet
Built into cylinder
4. Photoelectric (diffuse/reflective)
Any material
Long distance
Model | Detection distance | Thread | Output
E2B-X5D1 | 5mm | M12 | NPN
E2B-X8D1 | 8mm | M12 | NPN
E2B-X10D1 | 10mm | M18 | NPN
E2B-X15D1 | 15mm | M30 | NPN
1. Material detected (metal/non-metal)
2. Detection distance
3. Mounting type (flush/non-flush)
4. Output (NPN/PNP)
5. Interface (M8/M12/lead wire)
6. Protection IP67
7. Operating voltage
1. Flush type (embedded)
Can be embedded in metal
Short distance
2. Non-flush type (non-embedded)
Cannot be embedded in metal
Long distance
3. Spacing
Side-by-side mounting > 3× diameter
Opposed mounting > 6× diameter
Function: detect human entry into hazardous zone, stop immediately
Principle: transmitter + receiver, multiple infrared beams
Types:
1. Type2 (basic)
Slow response
Suitable for low risk
2. Type4 (high performance)
Fast response (<20 ms)
Self-diagnosis
Suitable for high risk
3. Resolution
14 mm (finger)
30 mm (hand)
70 mm (arm)
500 mm (body)
Model: F3SG-4RA0250N30
4R — Type4
A — standard
0250 — protected height 250 mm
N — NPN
30 — beam pitch 30 mm
Protected height: 160–1240 mm
Number of beams: 4–32
Detection distance: 0.2–7 m
Response time: 8–15 ms
SIL: Safety Integrity Level (SIL2/SIL3)
PL: Performance Level (PLd/PLe)
Function: detect guard door open/close
Types:
1. Mechanical
Limit switch
Simple, can be bypassed
2. Magnetic
Reed switch
Non-contact
3. RFID-coded
Unique identification
Bypass-proof
4. Electromagnetic lock
Door locked
Unlock condition (safety confirmation)
Function: safety signal processing
Model: Omron G9SX
Functions:
Emergency stop handling
Light curtain signal
Door switch
Two-hand operation
Safety output
Safety level: PLd/SIL2
1. Risk assessment
2. Select safety level
3. Safety distance calculation
S = K×T+C
K — human approach speed (2 m/s)
T — total response time
C — additional distance
4. Installation
Light curtain distance > safety distance
5. Interlock logic
Entering hazard zone → stop
Recovery → manual confirmation
Other quick references in this series:Servo MotorGearboxVariable Frequency DriveCylinderPneumatic ComponentsHydraulic ComponentsPLCTouchscreenElectrical ComponentsCouplingBearingValveMotor