Standard Equipment Explained · Sensors (Quick Reference)

Omron photoelectric switch selection and specifications

[Omron Photoelectric Switch Series]

1. E3Z (built-in amplifier, most common)

Thread M8/M12

Detection method: through-beam / retro-reflective / diffuse reflective

Detection distance: 1 m / 3 m / 15 m

Response time: 1 ms

2. E3F (separate amplifier)

Long distance

Fiber type

3. E3X (fiber amplifier)

High precision

Tiny objects

4. E3C (laser)

Long distance

Precise

[E3Z Specifications]

Model | Detection method | Detection distance | Interface | Output

E3Z-D61 | Diffuse reflective | 1 m | M8 | NPN

E3Z-D62 | Diffuse reflective | 1 m | M8 | PNP

E3Z-R61 | Retro-reflective | 2 m | M8 | NPN

E3Z-T81 | Through-beam | 15m | M8 | NPN

E3Z-LS61 | Limited-distance reflective | 1m | M8 | NPN

[Detection Method Selection]

1. Through-beam type (opposed mode)

Separate emitter and receiver units

Triggered when an object blocks the beam

Pros: long distance, reliable

Cons: wiring required at both ends

Suitable for: large objects, long distance, high reliability

2. Retroreflective type

Emitter and receiver in one unit + reflector

Triggered when an object blocks the reflected light

Pros: wiring at only one end

Cons: moderate distance

Suitable for: general detection

3. Diffuse-reflective type

Combined emitter/receiver

Triggered by light reflected from the object's surface

Pros: no reflector needed

Cons: affected by object color/surface

Suitable for: small objects, irregular objects

4. Limited-distance reflective type

Precisely limits the detection distance

Eliminates background interference

Suitable for: edge detection / thickness

[Output Types]

1. NPN (source type)

24V sink in

Suitable for Japanese / Chinese equipment

2. PNP (sink type)

24V output

Suitable for European equipment

3. Relay

Contact output

Suitable for high current

[Connection Method]

1. M8/M12 plug-in connector

Quick connection

Standardized

Suitable for batch

2. Direct-wired cable

2 m / 5 m cable

Economical

[Selection Steps]

1. Determine the object to be detected

- Size / shape / color / material

- Transparent / opaque

- Surface finish

2. Determine the detection distance

3. Choose the detection method

- Through-beam: long distance / reliable

- Retroreflective: general purpose

- Diffuse-reflective: no reflector

4. Choose the output type

- Match the PLC input

- NPN/PNP

5. Select interface

- M8/M12 connector

- Lead wire

6. Protection class

- IP65 (splash-proof)

- IP67 (temporary immersion)

7. Operating environment

- Temperature

- Vibration

- Electromagnetic interference

[Calculation Example]

Requirement: detect boxes on a conveyor (50×50×30 cm) at a distance of 1 m

1. Choose the diffuse-reflective E3Z-D61

Distance 1 m

The boxes are large, so reflection is sufficient

2. Output

The PLC is sink type, so choose PNP

E3Z-D62

3. Interface

M8 connector

4. Protection

IP67

[Installation Notes]

1. Avoid direct strong light (incandescent lamps / sunlight)

2. Avoid mutual interference (side-by-side mounting >50 mm)

3. Align the reflector (retroreflective)

4. Keep the object surface clean

5. Reinforce the mounting where vibration occurs

6. Wire correctly (NPN / PNP)

Keyence Displacement Sensors and Vision Systems

[Keyence Displacement Sensors]

1. Laser displacement sensor (high precision)

a. IL series (confocal)

Resolution 0.01 μm

Distance 0.5~30 mm

Accuracy ±0.1 μm

Suitable for: semiconductors / precision work

b. LR-Z series (triangulation)

Distance 20~500 mm

Resolution 1~10 μm

Suitable for: general

c. LR-T series (long distance)

Distance 0.1~5 m

Resolution 0.1 mm

Suitable for: level / distance

2. Inductive displacement sensor

a. EX-V series

Resolution 0.5 μm

Distance 0~2 mm

Suitable for: metal part measurement

b. GT2 series (contact type)

Resolution 0.5 μm

Measuring range 10~50 mm

Suitable for: in-line measurement

3. Ultrasonic displacement

a. UD series

Distance 30~6000 mm

Resolution 0.1~3 mm

Suitable for: transparent objects / liquid level

[Laser Displacement Principle]

1. Triangulation method

Laser obliquely hits object

The receiver (CCD/PSD) forms an image at different positions

Distance → image position

High accuracy, short distance

2. Confocal method

Wavelength dispersion

Different distances correspond to different wavelengths

Extremely high accuracy, short distance

3. Time of flight (TOF)

Measure light round-trip time

Long distance, medium accuracy

[Keyence Vision Systems]

1. CV-X series (high-speed, general purpose)

Camera: 21 MP

Processing speed: high

Programming: simple (flowchart-based)

Suitable for: general inspection

2. XG-X series (high precision)

Camera: 25 MP

21 inspection tools

Suitable for: complex inspection

3. IV2 series (smart camera)

Built-in processing

Compact

Simple inspection

[Vision Inspection Functions]

1. Dimensional measurement

Length / width / angle / circle diameter

Accuracy 1~10 μm

2. Defect detection

Scratches / chips / stains

Edge / corner

3. Character recognition (OCR/OCV)

Printed characters

Serial number

Barcode / QR code

4. Pattern matching

Shape recognition

Counting

Locating

5. Color inspection

Color difference

Color mark

6. 3D measurement (optional)

Height

Volume

Shape

[Camera Selection]

1. Area-scan camera

2D image

General purpose

Resolution: 0.3 MP~25 MP

2. Line-scan camera

Continuous scanning

Suitable for: web material / high speed

Resolution: 1K~16K

3. 3D camera

Stereo vision

Structured light

TOF

[Selection Points]

1. Field of view (FOV)

Must be larger than the object size

FOV = working distance × sensor size / focal length

2. Accuracy

Accuracy = FOV / number of pixels

Example: FOV=100 mm, 1024 pixels

Accuracy = 100/1024 = 0.1 mm

3. Working distance

4. Frame rate

Static: 10~30 fps

Dynamic: 60~1000 fps

5. Interface

GigE (most commonly used)

USB3.0

CameraLink

6. Lighting

Ring / bar / coaxial / backlight

Contrast

[Application Scenarios]

1. Dimensional measurement (accuracy 0.01 mm)

2. Surface defects (scratches / stains)

3. Assembly inspection (missing / wrong parts)

4. Character recognition (printed / coded)

5. Barcodes / 2D codes

6. Robot guidance (positioning)

7. Color sorting

8. Counting

[Selection Example]

Requirement: inspect parts 0~20 mm, accuracy 0.01 mm

1. Accuracy requirement

Accuracy = FOV / pixels

0.01mm×1024=10.24mm FOV

Choose FOV=20 mm, 2048 pixels

Accuracy = 20/2048 = 0.0098 mm ✓

2. Camera

5 megapixels (2592×1944)

FOV 20mm

3. Lens

Telecentric lens (eliminates perspective)

Magnification 0.1X

4. Lighting

Backlight (clear outline)

5. System

CV-X series

Temperature Sensor Selection and Application

[Temperature Sensor Types]

1. Thermocouple (TC)

Principle: a temperature difference at the junction of two metals generates a voltage

Measurement: -200~1800℃

Accuracy: ±1~5℃

Response: fast

2. Resistance temperature detector (RTD)

Principle: metal resistance varies with temperature

PT100: 0℃=100Ω, α=0.00385

PT1000: 0℃=1000Ω

Measurement: -200~600℃ (PT)

Accuracy: ±0.1~1℃

Response: medium

3. Thermistor (NTC/PTC)

Principle: semiconductor resistance varies with temperature

NTC: negative temperature coefficient

PTC: positive temperature coefficient

Measurement: -50~300℃

Accuracy: ±0.5~2℃

Response: fast

Low cost

4. Semiconductor temperature sensor

Principle: integrated circuit

LM35/DS18B20

Measurement: -55~150℃

Accuracy: ±0.5℃

Digital output

5. Infrared thermometer

Principle: measures infrared radiation

Non-contact

Measurement: -50~3000℃

Accuracy: ±1~2%

[Thermocouple Calibration Types]

Type K (chromel-alumel): -200~1300℃, general purpose

Type J (iron-constantan): -40~750℃

Type T (copper-constantan): -200~350℃

Type E (chromel-constantan): -200~900℃

Type N (nicrosil-nisil): -200~1300℃

Type S (platinum-10% rhodium / platinum): 0~1600℃

Type R (platinum-13% rhodium / platinum): 0~1600℃

Type B (platinum-30% rhodium / platinum-6% rhodium): 600~1800℃

[RTD Wiring]

1. Two-wire

Lead resistance affects reading

Low accuracy

Suitable for short distance

2. Three-wire (most commonly used)

Lead compensation

Medium accuracy

Industrial standard

3. Four-wire

Fully eliminates leads

Highest accuracy

Laboratory / precision

[Selection Considerations]

1. Temperature range

-200~600℃: PT100

600~1300℃: Type K thermocouple

1300~1800℃: Type S/R/B

2. Accuracy

±0.1℃: PT100 (Class A)

±1℃: Type K thermocouple

±2℃: NTC

3. Response speed

Fast: thermocouples / NTC

Medium: RTD

Slow: RTDs with protective sleeves

4. Environment

Vibration: thermocouples are better

Corrosion: select material

High pressure: sheath

5. Distance

Short (<10 m): any type

Medium (10~100 m): three-wire PT100 / thermocouple

Long (>100 m): transmitter 4-20mA

6. Cost

Low: NTC / thermocouple

Medium: PT100

High: high-precision PT100 / Type S

[Installation Method]

1. Direct insertion (no thermowell)

Fast response

Not pressure resistant

Suitable for: air / atmospheric pressure

2. With thermowell

Protects sensor

Pressure resistant

Slow response

Suitable for: pipes / pressure vessels

3. Surface mounting

Measure surface temperature

Magnet / welding / adhesive

4. Embedded

Embedded in solid

Measure internal temperature

[Calculation Example]

Requirement: measure the hydraulic oil tank temperature, 0~100℃, accuracy ±1℃

1. Choose PT100

Range suitable

Accuracy met

Good stability

2. Three-wire

Moderate distance

Compensate leads

3. With sheath

Oil environment

Easy to replace

4. Transmitter

4-20mA output

Transmit to PLC remotely

5. Installation

Tank side

Immersed in oil

Keep away from the return oil (high temperature)

Place near the pump suction (representative temperature)

Pressure Sensor Selection and Application

[Pressure Sensor Types]

1. Strain-gauge type

Elastic element + strain gauge

Accuracy 0.1~0.5%

General purpose

2. Piezoresistive type

Semiconductor diffusion

Accuracy 0.05~0.5%

Compact

3. Capacitive type

Capacitance change

Accuracy 0.05~0.1%

High precision

4. Piezoelectric type

Piezoelectric effect

Dynamic measurement

Cannot measure static pressure

5. Sapphire

High temperature

High precision

[Output Signals]

1. 4-20mA (most commonly used)

Two-wire

Interference resistant

Long distance

2. 0-10V/1-5V

Voltage

Short distance

3. RS485/Modbus

Digital

Multi-point

4. HART

Analog signal with superimposed digital data

5. PROFINET/IO-Link

Industrial Ethernet

[Measurement Range]

Gauge pressure: relative to atmospheric pressure

Absolute pressure: relative to vacuum

Differential pressure: difference between two points

[Accuracy Class]

0.05%: high precision

0.1%: precision

0.25%: industrial standard

0.5%: general

1.0%: economy

[Selection]

1. Range

Normal operation at 30~70% of full scale

Maximum <90%

2. Medium

Gas / liquid

Corrosive

Temperature

3. Accuracy

4. Output signal

5. Process connection (thread / flange)

6. Protection class

7. Explosion-proof (hazardous environments)

Encoder Selection and Application

[Encoder Types]

1. Incremental

Outputs A/B/Z phase pulses

Loses position on power loss

Simple, economical

2. Absolute

Each position corresponds to a unique code

Retained on power loss

Multi-turn (battery / gear memory)

3. Optical

Grating disk + photoelectric detection

High resolution

Sensitive to contamination

4. Magnetic

Magnetic scale + Hall-effect detection

Environment resistant

Medium resolution

[Resolution]

Incremental: 100~100000 pulses/rev

Absolute: 17bit (131072)~26bit (67108864)/rev

[Output Signals]

1. Incremental

- TTL/RS422 (differential, noise-immune)

- HTL (single-ended)

- Open collector

2. Absolute

- Parallel (Gray code)

- SSI (synchronous serial)

- BiSS (bidirectional)

- EnDat (Heidenhain)

- PROFINET/EtherCAT

[Selection]

1. Resolution

Positioning accuracy = 360° / resolution

17bit: 0.0028°

23bit: 0.000043°

2. Type

- Simple speed measurement: incremental

- Precise positioning: absolute

- Multi-turn: retains position after power loss

3. Interface

- Match the servo / PLC

- Communication protocol

4. Environment

- Vibration

- Contamination (photoelectric encoders are vulnerable)

- Magnetic field (EMI-sensitive)

5. Installation

- Shaft end (solid/hollow)

- Flange

- Coupling / direct

[Common Brands]

Heidenhain

Baumer

Renishaw

Omron

Nikon

Proximity switch selection and specifications

[Proximity Switch Types]

1. Inductive (metal)

Detects metal

Distance 1–15 mm

No contact wear

Most common

2. Capacitive

Detects metal/non-metal

Distance 1–25 mm

Adjustable sensitivity

3. Magnetic (reed switch)

Detects magnet

Built into cylinder

4. Photoelectric (diffuse/reflective)

Any material

Long distance

[Inductive Specifications (Omron)]

Model | Detection distance | Thread | Output

E2B-X5D1 | 5mm | M12 | NPN

E2B-X8D1 | 8mm | M12 | NPN

E2B-X10D1 | 10mm | M18 | NPN

E2B-X15D1 | 15mm | M30 | NPN

[Selection]

1. Material detected (metal/non-metal)

2. Detection distance

3. Mounting type (flush/non-flush)

4. Output (NPN/PNP)

5. Interface (M8/M12/lead wire)

6. Protection IP67

7. Operating voltage

[Installation]

1. Flush type (embedded)

Can be embedded in metal

Short distance

2. Non-flush type (non-embedded)

Cannot be embedded in metal

Long distance

3. Spacing

Side-by-side mounting > 3× diameter

Opposed mounting > 6× diameter

Safety light curtains and safety door switches

[Safety Light Curtain (ESPE)]

Function: detect human entry into hazardous zone, stop immediately

Principle: transmitter + receiver, multiple infrared beams

Types:

1. Type2 (basic)

Slow response

Suitable for low risk

2. Type4 (high performance)

Fast response (<20 ms)

Self-diagnosis

Suitable for high risk

3. Resolution

14 mm (finger)

30 mm (hand)

70 mm (arm)

500 mm (body)

[Specifications (Omron F3SG)]

Model: F3SG-4RA0250N30

4R — Type4

A — standard

0250 — protected height 250 mm

N — NPN

30 — beam pitch 30 mm

Protected height: 160–1240 mm

Number of beams: 4–32

Detection distance: 0.2–7 m

Response time: 8–15 ms

[Safety Level]

SIL: Safety Integrity Level (SIL2/SIL3)

PL: Performance Level (PLd/PLe)

[Safety Door Switch]

Function: detect guard door open/close

Types:

1. Mechanical

Limit switch

Simple, can be bypassed

2. Magnetic

Reed switch

Non-contact

3. RFID-coded

Unique identification

Bypass-proof

4. Electromagnetic lock

Door locked

Unlock condition (safety confirmation)

[Safety Relay]

Function: safety signal processing

Model: Omron G9SX

Functions:

Emergency stop handling

Light curtain signal

Door switch

Two-hand operation

Safety output

Safety level: PLd/SIL2

[Safety Design]

1. Risk assessment

2. Select safety level

3. Safety distance calculation

S = K×T+C

K — human approach speed (2 m/s)

T — total response time

C — additional distance

4. Installation

Light curtain distance > safety distance

5. Interlock logic

Entering hazard zone → stop

Recovery → manual confirmation

Other quick references in this series:Servo MotorGearboxVariable Frequency DriveCylinderPneumatic ComponentsHydraulic ComponentsPLCTouchscreenElectrical ComponentsCouplingBearingValveMotor

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL