1. Pressure control valves
- Relief valve (safety / pressure regulation)
- Pressure reducing valve
- Sequence valve
- Pressure switch
2. Flow control valves
- Throttle valve
- Speed control valve
- Flow divider / combiner valve
3. Directional control valves
- Check valve
- Directional valve (manual / solenoid / electrohydraulic)
- Pilot-operated check valve
4. Proportional / servo valves
- Proportional pressure valve
- Proportional flow valve
- Servo valve
5. Cartridge Valves
- Logic valve
- High flow
6. Sandwich (Stacking) Valves
- Standardized
- Compact
1. Solenoid directional valve (WE series, Rexroth)
Nominal size: WE5 (6mm) / WE6 (6mm) / WE10 (10mm)
Flow: WE5=14 L/min, WE6=60 L/min, WE10=100 L/min
Pressure: 31.5 MPa
WE6 specifications:
Port size 6 mm
Max flow 60 L/min
Max pressure 31.5 MPa
Voltage DC24V / AC230V
Positions / ways: 3-position 4-way / 2-position 4-way
Spool function: A/B/C/E/G/H/J/L/M/P/R/T/U/V/W, etc.
2. Electrohydraulic directional valve (WEH series)
Nominal size: WEH16 / WEH25 / WEH32
Flow: WEH16=300, WEH25=800, WEH32=1100 L/min
Pilot control: internal / external oil supply
Suitable for high flow
1. DBT (direct-operated)
Nominal size: 6/8/10mm
Pressure: 0.5~31.5 MPa (adjustable)
Flow: 2~40 L/min
2. DB/DBW (pilot-operated)
Nominal size: 8/10/15/20/25/30mm
Pressure: 0.5~35 MPa
Flow: 100~600 L/min
DB6 specifications:
Port size 6 mm
Max flow 40 L/min
Pressure range 0.5~31.5 MPa
1. Proportional relief valve
DBE / DBET series
Current 0~800 mA corresponds to 0~Pmax
Hysteresis <1%
Response time <100 ms
2. Proportional directional valve
4WRA / 4WRZ series
Valve opening is proportional to the current
Controllable flow + direction
Suitable for: speed control
3. Servo valve
4WS series
Response <10 ms
Hysteresis <0.1%
Suitable for: precision position control
1. Determine the flow
Q_valve ≥ Q_system
2. Determine the pressure
P_valve ≥ P_system
3. Select port size
Select by flow
Too small a nominal size → large pressure drop
Too large a nominal size → slow response
4. Select control mode
- Manual: simple
- Solenoid: automatic
- Electrohydraulic: high flow
- Proportional: continuous control
- Servo: high precision
5. Select spool function
Directional valve spool functions (O/H/Y/M, etc.)
Center position state
6. Select voltage
DC24V (common)
AC220V
Requirement: hydraulic cylinder with a 40 bore, speed 100 mm/s, pressure 14 MPa
1. Flow
Q = π/4×0.04²×0.1×60×1000 = 75.4L/min
2. Select the directional valve
WE6 (60 L/min) → not enough
WE10(100L/min) ✓
3. Select the relief valve
Pressure 14 MPa
Flow 75 L/min
Select DB10 (nominal size 10, flow 100 L/min)
4. Solenoid
DC24V
2-position 4-way or 3-position 4-way
1. Subplate mounting (sandwich valve)
2. Threaded connection
3. Flange connection (large nominal size)
4. Manifold block (custom)
1. Spool sticking
- Oil contamination
- Cleaning
2. Solenoid fails to actuate
- Coil burned out
- No signal received
3. Internal leakage
- Spool wear
- Replacement
4. Noise
- Cavitation
- Resonance
5. Unstable pressure
- Relief valve malfunction
- Air in system
1. By number of positions
- Two-position valve (2-position)
- Three-position valve (3-position, with center position)
2. By number of ports
- Two-way (2/2)
- Three-way (3/2)
- Four-way (4/2)
- Five-way (5/2)
3. By control
- Single solenoid
- Double solenoid
4. By medium
- Pneumatic
- Hydraulic
Center-position spool functions of 3-position 4-way valves:
Type O: all ports blocked (fully closed at center)
Type H: all ports open (fully open at center)
Type Y: A, B and O connected, P blocked
Type P: P, A and B connected, O blocked
Type M: P and O connected, A and B blocked (pump unloaded)
Type K: P, A and O connected, B blocked
Type C: P and A connected, B and O blocked
Type N: B and O connected, P and A blocked
Type J: B and O connected, P and A blocked
Type X: half-open (throttled)
Type O: holds position at center (commonly used)
Type H: system unloaded, cylinder free
Type Y: cylinder floating (float position)
Type M: pump unloaded (energy saving)
Type H: cylinder floating + pump unloaded
Flow: Q = Cv × √(ΔP/ρ)
Cv — flow coefficient
ΔP — differential pressure
Valve selection:
1. Flow matching
2. Pressure matching
3. Spool function
4. Voltage
5. Explosion-proof
6. Manual operation
1. Cylinder control (pneumatic)
2. Hydraulic cylinder / motor control (hydraulic)
3. Multi-way valve (construction machinery)
4. Valve terminal integration
Other quick references in this series:Servo MotorGearboxVariable Frequency DriveCylinderPneumatic ComponentsHydraulic ComponentsSensorPLCTouchscreenElectrical ComponentsCouplingBearingMotor