Enter load inertia and acceleration time to compute acceleration torque, required power and inertia ratio. Essential for preliminary motor selection of non-standard equipment.
Ta=JL·ω/t(ω=2πn/60);T=TL/η+Ta;P=T·n/9550。Inertia ratio rule of thumb: ≤10 general, ≤5 high-dynamic.Reflection: with gear ratio i, reflected load inertia =J/i² (a reducer cuts reflected inertia quadratically).Check rated torque against TL for continuous duty and peak torque for acceleration (motor peak ≈2.5~3× rated).