Interference Fit Assembly Methods and Parameters

Comparison of press/thermal/cold fit, thermal-fit temperature estimation formula and assembly notes for interference-part process cards.

MethodApplicable interference/diameterTemperature/equipmentKey points
Press fit (press)Small interference, small parts—Even speed, avoid impact, apply oil, estimate press force by calculator
Thermal fit (temperature differential)Medium interference, most commonHeat to 100~250°C (oil bath/induction/electric furnace)Expansion = α·d·Δt; above 250°C guard against annealing/distortion
Cold fit (shrink fit)Thin-wall/precision, avoid heatingDry ice −78°C / liquid nitrogen −196°CBore shrinks onto shaft, minimal distortion
Hydraulic mounting (oil injection)Large-part taper fitHigh-pressure oil pumpTaper expands shaft, repeatable assembly (coupling/sleeve)

Notes & calculation basis

Thermal-fit temperature T = (interference δ + assembly clearance g)/(α·d) + room temp, α steel ≈ 11×10⁻⁶/°C, g = 0.01~0.02 mm (leave insertion clearance) — compute with the accompanying interference-assembly calculator. After seating, avoid forced cooling/water splash (stress freeze), just cool naturally.

Online calculator

Run the numbers right away: Interference Fit Assembly Calculator (heating temp / press force) »

Data compiled from publicly available GB/T standard tables for design reference only. For final design and acceptance, always consult the original standard and the latest supplier catalog.

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »