Comparison of press/thermal/cold fit, thermal-fit temperature estimation formula and assembly notes for interference-part process cards.
| Method | Applicable interference/diameter | Temperature/equipment | Key points |
|---|---|---|---|
| Press fit (press) | Small interference, small parts | — | Even speed, avoid impact, apply oil, estimate press force by calculator |
| Thermal fit (temperature differential) | Medium interference, most common | Heat to 100~250°C (oil bath/induction/electric furnace) | Expansion = α·d·Δt; above 250°C guard against annealing/distortion |
| Cold fit (shrink fit) | Thin-wall/precision, avoid heating | Dry ice −78°C / liquid nitrogen −196°C | Bore shrinks onto shaft, minimal distortion |
| Hydraulic mounting (oil injection) | Large-part taper fit | High-pressure oil pump | Taper expands shaft, repeatable assembly (coupling/sleeve) |
Thermal-fit temperature T = (interference δ + assembly clearance g)/(α·d) + room temp, α steel ≈ 11×10⁻⁶/°C, g = 0.01~0.02 mm (leave insertion clearance) — compute with the accompanying interference-assembly calculator. After seating, avoid forced cooling/water splash (stress freeze), just cool naturally.
Run the numbers right away: Interference Fit Assembly Calculator (heating temp / press force) »
Data compiled from publicly available GB/T standard tables for design reference only. For final design and acceptance, always consult the original standard and the latest supplier catalog.