Section geometric properties are the starting point of every strength and stiffness calculation: get the moment of inertia wrong and all the stresses, deflections and stability results derived from it are worthless. Rectangular sections are manageable, but as soon as you meet an I-beam, a channel or a T-section — composite sections — you have to use the parallel axis theorem to assemble several rectangles. Below we work through a 6 m span I-beam lifting girder, then expand into the formulas and quick reference tables.
Duty condition: a simply supported lifting girder in a workshop, span L = 6 m, with a 10 t load suspended at mid-span (taken as P = 98 kN). The girder is a welded I-beam: depth 400, flange width 200, flange thickness 12, web thickness 8 mm, material Q235, allowable bending stress [σ] = 140 MPa, allowable deflection [f] = L/400. Calculate the section geometric properties and verify whether it can lift 10 t.
The first move with any composite section is always to "break it up". The I-beam splits into three rectangles:
| Block | Dimensions b×h (mm) | Area A (mm²) | Own centroid height (mm) |
|---|---|---|---|
| Top flange | 200×12 | 2400 | 394 |
| Web | 8×376 | 3008 | 200 |
| Bottom flange | 200×12 | 2400 | 6 |
Web depth = 400 − 2×12 = 376 mm; total area A = 2×2400 + 3008 = 7808 mm² (78.08 cm²).
The section is symmetric about the horizontal axis, so the neutral axis must be at mid-depth. But do not stop at "it looks symmetric" — verify it taking the bottom edge as the reference axis:
The centroid is exactly at mid-depth, and the neutral axis is 200 mm from the outer face of each flange ✓. The section is symmetric about both the horizontal and the vertical axis, so the centroid is also the intersection of the centroidal principal axes.
The moment of inertia of each rectangle about its own centroidal axis is I₀ = b·h³/12 (note that the depth is cubed, and it is always taken about its own centroid):
Do not start adding yet! What you have here is only "each block by itself"; the distance from the neutral axis has not been accounted for. The real contribution comes in the next step.
The parallel axis theorem: I = I₀ + A·d², where d is the distance from the centroid of that block to the neutral axis.
Flanges: d = 200 − 12/2 = 194 mm, d² = 37 636 mm²
Web: its centroid lies on the neutral axis, d = 0 → I = I₀ = 35 438 251 mm⁴
Compare: the own moment of inertia of a flange is only 28 800, but after the parallel axis shift it becomes 90 355 200, more than 3000 times larger — this is the mathematical reason why "the flanges of an I-beam must be made wide and placed far from the web".
While we are here, the vertical moment of inertia Iy: the two flanges each give 12×200³/12 = 8 000 000, the web 376×8³/12 ≈ 16 043 → Iy ≈ 1.602×10⁷ mm⁴, only 1/13.5 of Ix. So an I-beam is very strong about the strong axis and very weak about the weak axis, and lateral bracing or cover plates must be added.
For a simply supported beam with a central concentrated load, the maximum moment M = P·L/4; from σ = M/Wx ≤ [σ] the maximum load is:
Verify against the actual suspended load P = 98 kN (10 t):
Deflection verification (E = 206 000 MPa):
Conclusion: a welded I-beam H400×200×8×12 in Q235 can lift 10 t over a 6 m span — strength 136 MPa (a margin of only 3%), deflection 9.9 mm (a margin of 34%). Strength governs the design; to save material further you must change the section (a taller web is better value than wider flanges), and to increase the load you must move to Q355.
The Baisi Technical Handbook has integrated this calculation module into the Group 0 Basic Tools calculation module. Enter the duty parameters and it automatically outputs the selection result. Say goodbye to paging through handbooks, to hand calculations and to rule-of-thumb estimates. —— Baisi Technical Handbook download https://pan.baidu.com/s/1bquayZpfas6oYBbG0gp3Gw?pwd=2giv
Section geometric properties are a set of quantities that "depend only on the shape and not on the material". In mechanical design, six of them are used every day:
| Name | Symbol | Unit | Used for |
|---|---|---|---|
| Area | A | mm² | Tension-compression stress σ = F/A |
| Centroid position | y_c、z_c | mm | Locating the neutral axis, the premise of every calculation |
| Moment of inertia | Ix、Iy | mm⁴ | Bending stress, deflection, column buckling |
| Bending section modulus | Wx = Ix/y_max | mm³ | Bending strength σ = M/W |
| Polar moment of inertia | Ip = Ix + Iy (circular section) | mm⁴ | Torsional stiffness φ = TL/(GIp) |
| Torsion section modulus | Wp = Ip/R | mm³ | Torsional strength τ = T/Wp |
| Radius of gyration | i = √(I/A) | mm | Column slenderness λ = μl/i |
Remember the division of labour in one line: strength depends on W, stiffness on I, stability on i. All three are derived from the same I, so if I is wrong, everything is wrong.
1. Rectangle about its own centroidal axis (the most basic building block):
2. Parallel axis theorem (the lifeblood of composite sections):
3. Summation of a composite section:
4. Solid / hollow circular section:
5. Strength and stiffness verification:
| Symbol | Meaning | Common values / notes |
|---|---|---|
| b、h | Block width and depth | h must be parallel to the plane of bending |
| d | Distance from the block centroid to the neutral axis | Always taken as a positive value; the square removes the direction |
| y_max | Distance from the neutral axis to the most distant fibre | Different above and below for an unsymmetric section; take the larger |
| E | Elastic modulus | Steel 2.06×10⁵ MPa (essentially the same for all steels) |
| [σ] | Allowable bending stress | Q235 static 140 / Q355 static 200 MPa |
| [f] | Allowable deflection | Ordinary beams L/400; crane girders L/500~L/750 |
Table 1 · Formulas of basic sections (about the centroidal axis shown):
| Section shape | Area A | Moment of inertia I | Section modulus W |
|---|---|---|---|
| Rectangle b×h | b·h | b·h³/12 | b·h²/6 |
| Solid circle d | πd²/4 | πd⁴/64 | πd³/32 |
| Hollow circle D/d | π(D²−d²)/4 | π(D⁴−d⁴)/64 | π(D⁴−d⁴)/(32D) |
| Thin-walled tube (mean diameter D) | π·D·t | π·D³·t/8 | π·D²·t/4 |
| Triangle b×h | b·h/2 | b·h³/36 | b·h²/24 |
Table 2 · Section properties of common I-beams (GB/T 706, about the strong axis):
| Designation | h×b×t_w×t_f (mm) | A (cm²) | Ix (cm⁴) | Wx (cm³) | i_x (cm) |
|---|---|---|---|---|---|
| I20a | 200×100×7×11.4 | 35.5 | 2370 | 237 | 8.16 |
| I25a | 250×116×8×13 | 48.5 | 5020 | 402 | 10.2 |
| I32a | 320×130×9.5×15 | 67.1 | 11 080 | 692 | 12.8 |
| I40a | 400×142×10.5×16.5 | 86.1 | 21 720 | 1086 | 15.9 |
| I45a | 450×150×11.5×18 | 102 | 32 240 | 1430 | 17.7 |
Note that the Wx of I40a = 1086 cm³ is almost identical to the 1080.7 cm³ of the welded girder in this example — the welded section (400×200×8×12) uses 78.1 cm² of material against the 86.1 cm² of I40a, so it saves material because the flanges are wider and the material is placed further from the web.
Table 3 · Relation between moment of inertia and load capacity (same area, different depth):
| Section (mm) | A (mm²) | Ix (mm⁴) | Relative bending capacity |
|---|---|---|---|
| Rectangle 100×100 | 10 000 | 8.33×10⁶ | 1.0 (baseline) |
| Rectangle 50×200 (rotated 90°) | 10 000 | 1.67×10⁷ | 2.0 |
| Rectangle 25×400 | 10 000 | 1.33×10⁸ | 16.0 |
| Hollow circle φ150/φ100 | 9817 | 1.83×10⁷ | 2.2 |
With the same amount of material, raising the depth from 100 to 400 increases the bending capacity by a factor of 16 (I ∝ h³). This is the fundamental reason why "a beam should be made deep rather than wide".
| Common error | Consequence | Correct practice |
|---|---|---|
| Calculating the moment of inertia with b·h³/12 and forgetting the parallel axis shift | Ix of an I-beam is underestimated by more than 5 times, so the deflection is falsely small and the strength falsely high | A composite section must use Σ(I₀ + A·d²) |
| Writing b·h³/12 as b·h² (or h³·b²) | Dimensional error, the moment of inertia is off by an order of magnitude | The unit of I is mm⁴; only W is mm³ |
| Taking the wrong parallel axis distance d (using the difference of centroid heights without halving) | d is off by a factor of two, so A·d² is off by a factor of four | Always measure d from the "target axis" to "the centroid of that block" |
| Using the moment of inertia I as if it were the section modulus W | The stress comes out y_max times too small and the check is simply wrong | σ = M/W, W = I/y_max; do not mix them up |
| Using the same y above and below for an unsymmetric section (T-section, channel) | The stress at the compression edge is underestimated and that edge yields first | Calculate y_max above and below separately and take the side with the larger stress |
| Checking strength only and skipping the deflection | The strength passes but the beam sags beyond the limit and the equipment jams | Verify strength and stiffness together; crane girders use L/500~L/750 |
| Using an I-beam about its weak axis as the main load direction | Iy is only 1/13 of Ix, so lateral instability results | Load the strong axis and brace the weak axis or add cover plates |
One final reminder: this example treats the 10 t as a concentrated load, which is a conservative simplification. In a real lifting girder the self-weight, any eccentricity of the lifting point and the dynamic factor (1.1~1.3 for lifting) must all be counted separately. Before issuing the drawing, re-check against GB/T 3811 or GB 50017.