Pipe nominal diameter DN vs recommended steel tube OD x wall, essential for piping design and flow velocity check. DN is flow capacity label, not tube OD.
| Nominal diameter DN | Steel tube OD x wall (rec.) (mm) | Line type | Remarks |
|---|---|---|---|
| 4 | 6×1 | Control line | Small-bore pressure/control |
| 6 | 8x1.5 or 10x1.5 | — | Alternative small-bore option |
| 8 | 12×1.5 | Hydraulic | Return/control line |
| 10 | 14×2 | Hydraulic | Pressure/return oil line |
| 15 | 18x2 or 22x2 | — | Alternative option |
| 20 | 25×2.5 | Hydraulic | General pressure line |
| 25 | 32×3 | Hydraulic | Pressure line |
| 32 | 38×3 | Hydraulic | Pressure line |
| 40 | 45×3 | — | |
| 50 | 57×3.5 | — | |
| 65 | 76×4 | — | |
| 80 | 89×4 | — | |
| 100 | 108×4 | — | |
| 125 | 133×4.5 | — | |
| 150 | 159×5 | — | |
| 200 | 219×6 | — | |
| 250 | 273×7 | — | |
| 300 | 325×8 | — | |
| 350 | 377×9 | — | |
| 400 | 426×10 | — | |
| 500 | 530×10 | — | |
| 600 | 630×12 | — |
Steel tube OD should match fitting (e.g. 24 deg cone DIN2353 bite/weld); GB/T 8163 fluid pipe, GB/T 3639 cold-drawn precision pipe both OK. Wall thickness by tb-131 working pressure check, not this table alone.