Bolt groups on brackets, corbels and flanges are almost never in pure shear — the load is usually eccentric, and eccentricity generates a moment. The moment distributes the load unevenly among the bolts, and the bolt at the most distant corner fails first. Below we work through a complete bracket bolt group example, then unfold the formulas and parameter tables.
The bracket base plate is fastened to the column flange with 8 M20 (property class 8.8) ordinary boltsand carries a vertical load F = 120 kN whose line of action is eccentric to the centroid of the bolt group by e = 300 mm. Bolt layout: 2 columns × 4 rows, column pitch 100 mm, row pitch 120 mm, single shear connection. Base plate thickness 12 mm (Q235), column flange thickness 14 mm.
The eccentric load is equivalent to a vertical shear F through the centroid plus a moment T:
All the calculations that follow are performed in the centroidal coordinate system of the bolt group.
The vertical shear is shared equally by the 8 bolts:
Each bolt first takes a share of 15 kN of vertical shear.
Taking the centroid as the origin, the bolt coordinates are: x = ±50 mm, y = ±60 / ±180 mm (row pitch 120, two columns symmetric). The squared distance of each bolt from the centroid is r² = x² + y²:
The force produced by the moment is proportional to the distance from the centroid, so the bolt at the most distant corner carries the largest force:
Resolve the moment force into horizontal and vertical components (the vertical component adds to the shear):
The most critical bolt is the one at the corner farthest from the centroid, with a resultant force of about 47.3 kN.
M20 (property class 8.8) ordinary bolt, shear strength design value fvb = 250 MPa, bearing strength of the Q235 member fcb = 405 MPa, single shear nv = 1, Σt = 12 mm (the smaller of the two plate thicknesses):
The most critical bolt carries 47.3 kN, less than the design capacity per bolt of 78.5 kN,so the 8 M20 (property class 8.8) bolts are acceptable, with a utilisation of about 60% that leaves room for detailing and safety margin.
⚠️ Try it: if M14 (property class 8.8) were used instead, the shear capacity would be only about 38.5 kN, below 47.3 kN,and the verification would fail. That is exactly why the moment must be calculated for a bolt group — looking only at the evenly shared shear, M14 appears to “do the job”, but once the moment is included the shortfall shows.
Bolt groups in shear are divided into two types by load-transfer mechanism, with completely different calculation models:
By loading pattern, bolt groups in shear are further divided intosimple shear(the load passes through the centroid) andeccentric shear(the load does not pass through the centroid and generates a moment). Eccentric shear is normal in engineering, and distributing the moment is the main event of the calculation.
Parameter notes:
| Symbol | Meaning | Unit |
|---|---|---|
| F | Transverse shear force carried by the connection | kN |
| e | Eccentricity from the shear line of action to the centroid | mm |
| T | Moment (T = F·e) | kN·mm |
| n | Total number of bolts | — |
| nv | Number of shear planes (single shear=1, double shear=2) | — |
| ri | Distance of the i-th bolt from the centroid | mm |
| Σt | Smaller total thickness of the bearing plates in the same direction | mm |
| fvb | Shear strength design value of the bolt | MPa |
| fcb | Bearing strength design value of the hole wall | MPa |
| Rmax | Resultant force on the most critical bolt | kN |
| Property class | 4.6 / 4.8 | 5.6 | 8.8 | 10.9 |
|---|---|---|---|---|
| fvb (MPa) | 140 | 190 | 250 | 310 |
| Member steel grade | 4.6 / 4.8 | 5.6 | 8.8 | 10.9 |
|---|---|---|---|---|
| Q235 (MPa) | 305 | 335 | 405 | 465 |
| Q355 (MPa) | 385 | 420 | 510 | 590 |
| Item | Recommended value | Notes |
|---|---|---|
| Bolt row pitch / column pitch | 3d ~ 5d | Facilitates tightening and uniform load transfer |
| End distance (in the load direction) | ≥ 2d | Prevents tearing at the end of the member |
| Edge distance (perpendicular to the load) | ≥ 1.5d | Values differ for rolled edges and sheared edges |
| Bolt hole diameter | d + 1.5 ~ 2 mm | Class I holes for ordinary bolts |
| Bolt arrangement | Symmetrical arrangement | Avoids an offset of the centroid producing an additional moment |
| Connection type | nv | Example |
|---|---|---|
| Single shear (one cover plate) | 1 | Single cover plate butt joint |
| Double shear (two cover plates) | 2 | Double cover plate butt joint, flanges |
| Triple shear and above | ≥3 | Lap joint with multiple plate layers |
⚠️ Important:take Σt as the smaller of the two plate thicknesses in the bearing direction(single shear), or the smaller of the sums of the plate thicknesses on both sides (double shear). Taking the larger plate thickness overestimates the bearing capacity — a common failure point.
| # | Common error | Consequence | Correct practice |
|---|---|---|---|
| 1 | Calculating only the even distribution of shear and forgetting the eccentric moment | The corner bolts are overloaded and the joint fails first | Reduce the load to the centroid first; T = F·e must be calculated |
| 2 | Distributing the moment equally over the number of bolts | Bolts far from the centroid are badly underestimated | Distribute in proportion to distance using FTi = T·ri/Σri² |
| 3 | Combining the forces algebraically (Fv + FT) | This deviates greatly from the true vector sum | Vector sum Rmax = √((Fv+FTy)² + FTx²) |
| 4 | Taking the larger plate thickness for the bearing Σt | The bearing capacity is falsely high and the hole wall is crushed | Take Σt as the smaller plate thickness in the bearing direction |
| 5 | Applying the high-strength friction-type formula (0.9·nf·μ·P) to ordinary bolts | The capacity is wrong by an order of magnitude | Use shear and bearing for ordinary bolts, and friction for the friction type |
Keep this four-step mnemonic in mind for bolt groups in shear:“1 reduce, 2 share evenly, 3 divide by distance, 4 verify”— reduce the load to the centroid to obtain the moment, share the shear equally, divide the moment in proportion to distance, then vector-sum the most critical corner bolt and compare it with the capacity per bolt. For eccentric loading, always look at the moment first.