Upper/lower deviations of h6/k6/m6/n6/p6/s6 over common size steps; direct reference for shaft-fit calculation.
| Deviation zone | >10-18 (mm) | >18-30 (mm) | >30-50 (mm) |
|---|---|---|---|
| h6 | 0/−11 | 0/−13 | 0/−16 |
| k6 | +12/+1 | +15/+2 | +18/+2 |
| m6 | +18/+7 | +21/+8 | +25/+9 |
| n6 | +23/+12 | +28/+15 | +33/+17 |
| p6 | +29/+18 | +35/+22 | +42/+26 |
| s6 | +39/+28 | +48/+35 | +59/+43 |
Format is upper/lower deviation (um). k6 is most common for bearing inner rings; s6 is heavy interference for shrink fit. Hole zones (H7/K7/N7/P7 etc.) per full GB/T 1800.2 table.
See all quick calculators on the knowledge base home page.
Data compiled from publicly available GB/T standard tables for design reference only. For final design and acceptance, always consult the original standard and the latest supplier catalog.