Theoretical thrust of the rodless chamber of common pneumatic cylinder bores at 0.4/0.5/0.63/0.8/1.0 MPa, for pneumatic selection.
| Bore D (mm) | 0.4 MPa (N) | 0.5 MPa (N) | 0.63 MPa (N) | 0.8 MPa (N) | 1.0 MPa (N) |
|---|---|---|---|---|---|
| 12 | 45 | 57 | 71 | 90 | 113 |
| 16 | 80 | 100 | 126 | 161 | 201 |
| 20 | 126 | 157 | 198 | 251 | 314 |
| 25 | 196 | 245 | 309 | 393 | 491 |
| 32 | 322 | 402 | 507 | 643 | 804 |
| 40 | 503 | 628 | 792 | 1005 | 1257 |
| 50 | 785 | 982 | 1237 | 1571 | 1963 |
| 63 | 1247 | 1559 | 1963 | 2488 | 3117 |
| 80 | 2011 | 2513 | 3167 | 4021 | 5027 |
| 100 | 3142 | 3927 | 4948 | 6283 | 7854 |
| 125 | 4909 | 6136 | 7711 | 9817 | 12272 |
| 160 | 8042 | 10053 | 12667 | 16085 | 20106 |
| 200 | 12566 | 15708 | 19792 | 25133 | 31416 |
The theoretical values do not account for friction (85%~95% in practice) and back pressure; the pneumatic line pressure drop is typically 0.05~0.1 MPa, so select by the end pressure.
Run the numbers right away: Pneumatic Cylinder Push/Pull Force Calculator »
Data compiled from publicly available GB/T standard tables for design reference only. For final design and acceptance, always consult the original standard and the latest supplier catalog.