MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
Knowledge Base › Pneumatics & Vacuum › Tensile Bolt Strength Verifica
HomeModels
Table of contents

Pneumatics & Vacuum (7 articles)

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

🛠️ Baisi Technical Handbook · Intelligent selection and calculation for 500+ standard parts
Covers the full range of pneumatic / motor / power transmission / reducer / coupling / bearing / hydraulic / pneumatic / thread / worm / spring parts
Avoid 95% of design errors, improve design efficiency by 80%
Master 10 years of senior engineer experience in 3 months
Download: https://pan.baidu.com/s/1bquayZpfas6oYBbG0gp3Gw?pwd=2giv

📖 Next issue preview: High-Strength Bolt Friction-Type Connections

Tensile Bolt Strength Verification Formulas and Worked Example: Cylinder Cover Bolts Explained in 5 Steps

Flanges, cylinder covers and bearing housings — all of these joints rely on tensile bolts to carry the axial load. A broken bolt is not merely a gas or oil leak; in severe cases the cover “flies off” and injures people. Below we work through one cylinder cover bolt group example, then unfold the formulas and the parameter selection.

1. Complete Worked Example: Strength Verification of a Cylinder Cover Bolt Group

Step 1 — Calculate the total axial load of the bolt group

Cylinder bore D = 250 mm, working pressure in the cylinder p = 1.5 MPa; total load from the gas pressure acting on the cylinder cover:

FΣ = p × πD²/4 = 1.5 × 3.1416 × 250²/4 ≈ 73631 N

This 73631 N is the total axial force shared by all 8 bolts.

Step 2 — Distribute it evenly to each bolt
F = FΣ / z = 73631 / 8 ≈ 9204 N

Each bolt carries a working tensile force of about 9204 N.

Step 3 — Set the residual preload and calculate the total bolt tension

A cylinder cover is a pressure vessel sealing joint, so it needs a large residual preload; take F'' = 1.5F:

F'' = 1.5 × 9204 ≈ 13806 N
F0 = F + F'' = 9204 + 13806 ≈ 23010 N

The total bolt tension F0 ≈ 23010 N is the core load used for the strength verification.

Step 4 — Back-calculate the required minor diameter area from the allowable stress

Choose property class 8.8 bolts, σs = 640 MPa; with controlled preload take a safety factor S = 2:

[σ] = σs / S = 640 / 2 = 320 MPa
A ≥ 1.3·F0 / [σ] = 1.3 × 23010 / 320 ≈ 93.5 mm²

The 1.3 factor accounts for the fact that a bolt is also subject to torsional shear stress while being tightened, which equivalently magnifies the tensile stress.

Step 5 — Look up the size in the table and verify

Consult the thread minor diameter cross-sectional area table: M12 (d1=10.106, A≈80.2 mm²) is not enough; M14 (d1=11.835, A≈110.0 mm²) satisfies the requirement. Verify:

σca = 1.3·F0 / A = 1.3 × 23010 / 110 ≈ 272 MPa < [σ] = 320 MPa ✓

Final selection: 8 × M14 (property class 8.8) bolts, installed with controlled preload torque, strength acceptable and safety margin ample.

🛠️ Baisi Technical Handbook · Connection and Shaft Calculation Module
The Baisi Technical Handbook integrates this calculation module into the Connection and Shaft Calculation Module. Enter the duty parameters and the selection result is output automatically. Say goodbye to flipping through handbooks, to hand calculations, to rule-of-thumb estimates. —— Baisi Technical Handbook download: https://pan.baidu.com/s/1bquayZpfas6oYBbG0gp3Gw?pwd=2giv

2. Fundamentals of Tensile Bolt Connections

The tensile bolt connection is the most common mechanical fastening form and is divided into two types depending on whether a preload is applied:

The load-carrying capacity of a bolt is determined by itsproperty class; the meaning of the digits is: the first two digits ×100 give the tensile strength σb (MPa), and the first two digits ×10 multiplied by the last digit give the yield strength σs (MPa). For example class 8.8: σb ≈ 800 MPa, σs = 8×8×10 = 640 MPa.

3. Core Calculation Formulas

1. Total axial load of the bolt group (pressure vessel cover)

FΣ = p · πD² / 4

2. Working load per bolt

F = FΣ / z

3. Total bolt tension

F0 = F + F'' (F'' is the residual preload)

4. Calculated bolt stress during tightening (core verification equation)

σca = 1.3 · F0 / A ≤ [σ]

5. Thread minor diameter cross-sectional area

A = π · d1² / 4

6. Allowable stress

[σ] = σs / S

Parameter notes:

SymbolMeaningUnit
pWorking pressure inside the vesselMPa
DSealing face diameter (cylinder bore diameter)mm
zNumber of bolts—
F''Residual preloadN
d1Thread minor diameter (critical section diameter)mm
σsBolt yield strengthMPa
SSafety factor—

4. Guide to Design Parameter Selection

1. Bolt property class and yield strength

Property classTensile strength σb (MPa)Yield strength σs (MPa)Typical applications
4.8400320General fastening, light load
5.8500400General machine connections
8.8800640Equipment flanges, cylinder covers (most common)
10.91000900High-strength connections, engines
12.912001080Heavy load, high-speed duty

2. Selection of safety factor S

Joint conditionLoad typeValue of S
Controlled preload (torque wrench / force-measuring wrench)Static load1.2 ~ 1.5
Variable load1.5 ~ 2.0
Uncontrolled preload (ordinary wrench)Static load2.5 ~ 4.0
Variable load5.0 ~ 8.0

⚠️ Important:the safety factor can be taken much smaller when the preload is controlled, because the tightening force is controllable and the bolt stress is well defined. With an ordinary wrench tightened by feel, the scatter is large and a large safety factor is mandatory. This is the pitfall beginners fall into most easily.

3. Empirical values for the residual preload F''

Joint typeValue of F''
General joint (static load)(0.2 ~ 0.6)F
Variable load joint(0.6 ~ 1.0)F
Sealing joints such as pressure vessels and cylinder covers(1.5 ~ 1.8)F
Anchor boltsCalculated separately from the overturning moment

4. Minor diameter and cross-sectional area of common coarse threads

SizeMinor diameter d1 (mm)Area A (mm²)
M86.64734.7
M108.37655.1
M1210.10680.2
M1411.835110.0
M1613.835150.3
M2017.294235.0
M2420.752338.2

5. Common Errors and How to Avoid Them

#Common errorConsequenceCorrect practice
1Using the nominal diameter d to compute the areaThe stress is underestimated by 20%~40% and the bolt is undersizedThe critical section is at the minor diameter; always calculate with d1
2Forgetting the 1.3 tightening factorTorsional shear stress is neglected and the actual stress is underestimated by about 30%Preloaded joints σca = 1.3·F0/A
3Taking the preload too small on a sealing jointGas or oil leaks and the bolts loosenFor sealing joints such as cylinder covers take F'' = (1.5~1.8)F
4Taking a small safety factor even though an ordinary wrench was used for installationThe preload scatter is large and the bolts breakTake S = 2.5~8 for uncontrolled preload, or switch to a torque wrench
5Checking strength only and ignoring thread crushing and fatigueFatigue fracture under variable loadVariable load duty requires verification against fatigue strength

Keep one mnemonic in mind for tensile bolt verification:“Use the minor diameter, multiply by 1.3, stay below the allowable stress”— use d1 for the area, multiply the load by 1.3, and the joint passes if the calculated stress is below [σ]. For sealing joints, take a somewhat larger preload so the equipment stays tight and leak-free for ten years.

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL