Flanges, cylinder covers and bearing housings — all of these joints rely on tensile bolts to carry the axial load. A broken bolt is not merely a gas or oil leak; in severe cases the cover “flies off” and injures people. Below we work through one cylinder cover bolt group example, then unfold the formulas and the parameter selection.
Cylinder bore D = 250 mm, working pressure in the cylinder p = 1.5 MPa; total load from the gas pressure acting on the cylinder cover:
This 73631 N is the total axial force shared by all 8 bolts.
Each bolt carries a working tensile force of about 9204 N.
A cylinder cover is a pressure vessel sealing joint, so it needs a large residual preload; take F'' = 1.5F:
The total bolt tension F0 ≈ 23010 N is the core load used for the strength verification.
Choose property class 8.8 bolts, σs = 640 MPa; with controlled preload take a safety factor S = 2:
The 1.3 factor accounts for the fact that a bolt is also subject to torsional shear stress while being tightened, which equivalently magnifies the tensile stress.
Consult the thread minor diameter cross-sectional area table: M12 (d1=10.106, A≈80.2 mm²) is not enough; M14 (d1=11.835, A≈110.0 mm²) satisfies the requirement. Verify:
Final selection: 8 × M14 (property class 8.8) bolts, installed with controlled preload torque, strength acceptable and safety margin ample.
The tensile bolt connection is the most common mechanical fastening form and is divided into two types depending on whether a preload is applied:
The load-carrying capacity of a bolt is determined by itsproperty class; the meaning of the digits is: the first two digits ×100 give the tensile strength σb (MPa), and the first two digits ×10 multiplied by the last digit give the yield strength σs (MPa). For example class 8.8: σb ≈ 800 MPa, σs = 8×8×10 = 640 MPa.
Parameter notes:
| Symbol | Meaning | Unit |
|---|---|---|
| p | Working pressure inside the vessel | MPa |
| D | Sealing face diameter (cylinder bore diameter) | mm |
| z | Number of bolts | — |
| F'' | Residual preload | N |
| d1 | Thread minor diameter (critical section diameter) | mm |
| σs | Bolt yield strength | MPa |
| S | Safety factor | — |
| Property class | Tensile strength σb (MPa) | Yield strength σs (MPa) | Typical applications |
|---|---|---|---|
| 4.8 | 400 | 320 | General fastening, light load |
| 5.8 | 500 | 400 | General machine connections |
| 8.8 | 800 | 640 | Equipment flanges, cylinder covers (most common) |
| 10.9 | 1000 | 900 | High-strength connections, engines |
| 12.9 | 1200 | 1080 | Heavy load, high-speed duty |
| Joint condition | Load type | Value of S |
|---|---|---|
| Controlled preload (torque wrench / force-measuring wrench) | Static load | 1.2 ~ 1.5 |
| Variable load | 1.5 ~ 2.0 | |
| Uncontrolled preload (ordinary wrench) | Static load | 2.5 ~ 4.0 |
| Variable load | 5.0 ~ 8.0 |
⚠️ Important:the safety factor can be taken much smaller when the preload is controlled, because the tightening force is controllable and the bolt stress is well defined. With an ordinary wrench tightened by feel, the scatter is large and a large safety factor is mandatory. This is the pitfall beginners fall into most easily.
| Joint type | Value of F'' |
|---|---|
| General joint (static load) | (0.2 ~ 0.6)F |
| Variable load joint | (0.6 ~ 1.0)F |
| Sealing joints such as pressure vessels and cylinder covers | (1.5 ~ 1.8)F |
| Anchor bolts | Calculated separately from the overturning moment |
| Size | Minor diameter d1 (mm) | Area A (mm²) |
|---|---|---|
| M8 | 6.647 | 34.7 |
| M10 | 8.376 | 55.1 |
| M12 | 10.106 | 80.2 |
| M14 | 11.835 | 110.0 |
| M16 | 13.835 | 150.3 |
| M20 | 17.294 | 235.0 |
| M24 | 20.752 | 338.2 |
| # | Common error | Consequence | Correct practice |
|---|---|---|---|
| 1 | Using the nominal diameter d to compute the area | The stress is underestimated by 20%~40% and the bolt is undersized | The critical section is at the minor diameter; always calculate with d1 |
| 2 | Forgetting the 1.3 tightening factor | Torsional shear stress is neglected and the actual stress is underestimated by about 30% | Preloaded joints σca = 1.3·F0/A |
| 3 | Taking the preload too small on a sealing joint | Gas or oil leaks and the bolts loosen | For sealing joints such as cylinder covers take F'' = (1.5~1.8)F |
| 4 | Taking a small safety factor even though an ordinary wrench was used for installation | The preload scatter is large and the bolts break | Take S = 2.5~8 for uncontrolled preload, or switch to a torque wrench |
| 5 | Checking strength only and ignoring thread crushing and fatigue | Fatigue fracture under variable load | Variable load duty requires verification against fatigue strength |
Keep one mnemonic in mind for tensile bolt verification:“Use the minor diameter, multiply by 1.3, stay below the allowable stress”— use d1 for the area, multiply the load by 1.3, and the joint passes if the calculated stress is below [σ]. For sealing joints, take a somewhat larger preload so the equipment stays tight and leak-free for ten years.