Electrical & Sensor Error Cases (474 cases)
Each case lists the problem symptom, root cause, correct solution and a practical checklist, drawn from real machine commissioning and design reviews.
Sensor Selection & Range (12 cases)
Mounting Position & Orientation (12 cases)
Cables & Cable Carriers (50 cases)
Signal Interference & EMC (50 cases)
Power Supply (50 cases)
Grounding & Shielding (50 cases)
- Signal Ground and Protective Earth Mixed, Ground Circulating Current PLC Analog Input Module★★
- Shielded Twisted Pair Grounded at Both Ends Forms a Ground Loop 4-20mA Signal Cable★★
- Single-Point Grounding Loses Earth at High Frequency, Radiation High-Frequency Sensor Shield Enclosure★
- High Grounding Resistance Prevents Surge Dissipation Field Sensor Grounding Electrode★★
- Analog and Digital Grounds Tied Together, Digital Noise Couples In Data Acquisition Card★★
- Cabinet Not Bonded to PE, Live Enclosure Control Cabinet★★★
- Cabinet-to-Cabinet Potential Difference Without Equipotential Bonding Damages Modules Inter-Cabinet Signal Line★★
- Floating Ungrounded Shield Picks Up Noise Thermocouple Extension Wire★
- Multi-Point Grounded Shield Acts as an Antenna (Electrical Sensor Error Case) Long Shielded Signal Cable★★
- Lightning Ground and Signal Ground Not Separated, Back-Flash Outdoor Transmitter★★★
- Electrostatic Shield Not Bonded to the Chassis, Field Leakage Capacitive Proximity Switch★
- Wrong Grounding Order for a Triple-Shielded Cable Servo Feedback Shielded Cable★★
- Floating Signal Ground with No Reference Drifts Load Cell★★
- Common-Mode Voltage Beyond the Interface Range Saturates Differential Pressure Transmitter★★
- No Isolation Between Chassis and Internal Circuit, Breakdown Integrated Temperature Transmitter★★
- Shield Connected to Signal Ground Introduces Noise Instead Strain Gauge Measurement Cable★
- Ground Grid Potential Difference Causes Measurement Drift Remote Pressure Sensor★★
- No Isolation Transformer to Break the Ground Loop Laboratory Measuring Instrument★★
- Protective Earth Mixed with Working Ground Causes Interference VFD Control Cabinet★★
- Damaged Shield Shorting to Ground Fieldbus Cable★★
- Unshielded Twisted Pair Coupling Low-Frequency Magnetic Noise Low-Frequency mV Signal Line★
- Low Braid Density Causes Poor Shielding Effectiveness Control-Signal Shielded Cable★
- Functional Earth Not Separated from Protective Earth Precision Measurement Cabinet★★
- Multi-Device Shared PE Bus Voltage-Drop Interference Side-by-Side Sensor Group★★
- Corroded Grounding Electrode Raises Resistance Again Outdoor Grounding Electrode★★
- Loose Termination on a High-Frequency Coaxial Connector High-Frequency Coaxial Signal Cable★★
- Multi-Point Grounding of the Signal Loop Causes Zero Drift Thermocouple Temperature System★★
- Equipotential Bar Not Continuous Through the Cabinet Control Cabinet Interior★
- Power and Signal Cables Sharing a Trench Cause Crosstalk Power and Weak-Signal Cables in the Same Trench★★
- Ground-Potential Fluctuation Makes the Encoder Count Jump Encoder Feedback Cable★★
- Shield Grounded at a Noise Point Brings in Noise Analog Signal Line★
- Cable Tray Not Bonded Across Sections - Electrical Discontinuity Cable Tray★
- Long Signal-Ground Lead to PE Loses Ground at High Frequency Remote Acquisition Module★★
- Multi-Point Shield Grounding Amplifies Resonance Long Shielded Cable★★
- Corroded Equipotential Terminal Causes Poor Contact Outdoor Equipotential Bonding Point★★
- Crosstalk Between Power Ground and Signal Ground Integrated Acquisition Instrument★★
- Shield Not Ring-Crimped at the Port, Leakage Path Field Sensor Connector★
- Grounding System Resonant Overvoltage Substation Grounding Grid★★
- Sensor Negative Terminal Wrongly Bonded to the Enclosure, Short Circuit Two-Wire Transmitter★★
- Wrong Grounding Defeats Common-Mode Rejection Differential-Input Instrument★★
- Non-Coaxial Shield Causes Unbalanced Capacitance and Loss of Symmetry Coaxial Measurement Cable★
- Repeated PE Earthing Causes Circulating Current Long-Run PE System★★
- Frame Not Earthed, Floating and Live Upright Equipment Frame★★★
- Undersized Grounding Down-Conductor Overheats Lightning Down-Conductor★★
- Signal Cable Running Parallel to the Grounding Busbar Picks Up Coupling Parallel Signal Cable and Grounding Busbar★★
- Strain Gauge Without Shielded Twisted Pair Picks Up Noise Strain Gauge Measurement Leads★
- Multi-Point Equipotential Bonding Creates a Loop Within the Network Equipotential Bonding of a Large Cabinet Group★★
- Shield Grounded at Both Ends Picks Up Lightning Induction Long Outdoor Shielded Cable★★★
- Enclosure Live with No Alarm Unnoticed Motorised Equipment Enclosure★★★
- Oxidised Grounding Busbar Has High Contact Resistance Cabinet Grounding Busbar★
Wiring & Terminals (50 cases)
- Loose Terminal and Poor Contact Make the Reading Jump Pressure Transmitter★
- Reverse Polarity Wiring Gives No Output Two-Wire Transmitter★
- Crimp Terminal Not Compressed - Wire Breaks Loose Thermocouple Junction Box★
- Wire Gauge Mismatched to Terminal Causing Overheating Terminal Block★
- Stranded Wire Without Tinning Frays and Breaks Encoder Cable Termination★
- Insufficient Creepage Distance on Terminal Block Causing Flashover 220V Terminal Block★
- Shield Miswired to Signal Ground Causing Ground Loop Current Analog Shielded Cable★
- Connector Not Locked, Loosening under Vibration Aviation Connector Sensor★
- Wrong Wire Numbers, Wrong Range Setting Load Cell★
- Short Leads in the Junction Box Losing the Signal Outdoor Level Gauge★
- Terminal Block Overload and Melting Power Terminal Block★
- No Crimped Lug Fitted, Circuit Opening in Service Motor Temperature PTC★
- Excessive Cable Length Causing Signal Attenuation 4-20mA Remote Transmission★
- Insufficient Terminal Torque Causing Heating and Oxidation VFD Cabinet Terminal★
- Galvanic Corrosion Between Dissimilar Metals Outdoor Junction Box★
- Tangled Wiring Causing a Short Inside the Control Cabinet★
- Over-Stripped Multi-Core Wire Causing a Short Terminal-Block Wiring★
- Confusing Wire Colors, Wrong Connections Encoder A/B Phases★
- Junction Box Seal Failure, Water Ingress Outdoor Temperature Transmitter★
- No Wire Marking Maintained, Wrong Connections Wiring After Maintenance★
- Uneven Voltage Drop Across Cascaded Terminal Blocks Distributed IO★
- Overfilled Wire Duct, Poor Heat Dissipation Control-Cabinet Harness★
- Flexible Wire Terminated Rigidly, Breaking After Repeated Flexing Lead of Swinging Equipment★
- Terminal Heating and Aging High-Current Sensor★
- Bent Connector Pins Causing Poor Contact Displacement-Sensor Plug★
- Wiring Diagram Does Not Match Reality Post-Modification System★
- Spring Terminal Fatigue Failure Long-Term-Service Terminal★
- Cross-Layer Interference Coupled into Signal Wiring Layered Cabinet Wiring★
- Mixing Power and Low-Level Circuits on One Terminal Block Mixed Terminal Block★
- Cold Solder Joint Causing Unstable Contact Board-Side Lead Solder Joint★
- No Slack Left in Wiring, Pulled Apart Lead Inside Cable Chain★
- Terminal Insulation Breakdown and Tracking High-Voltage-Side Terminal★
- Overlong Shield Ground Lead Acting as an Antenna Analog Shielding★
- Condensation Inside the Junction Box Site with Large Temperature Swings★
- Insufficient Terminal Redundancy, Single-Point Failure Critical Measuring Point★
- Terminals Not Phase-Marked Three-Phase Current★
- Stranded Wire Put Straight into the Terminal, Strand Breakage Temporary Field Wiring★
- Terminal Over-Torqued and Cracked Plastic Terminal Body★
- Wire Coiled into a Loop Picking Up Induction Signal Wire Coiled on Conduit★
- Wrong Crimp Terminal Selection, Loose Crimp High-Current Terminal★
- Galvanic Corrosion Loosening Terminals Seaside Salt-Spray Site★
- Unsecured Wire Chafed Through by Swinging Lead of Moving Equipment★
- Terminal Block Not Fixed, Shifting Suspended Terminal Block★
- Twisted Pair Unstranded Too Far Shielded Twisted Pair★
- Terminal Overheating, Excessive Temperature Rise High-Current Busbar★
- Wiring Error Causing Common-Mode Overvoltage Differential Input Signal★
- Plug Not Fully Seated, Loose Contact Field Quick Connector★
- Terminal Tracking Caused by Contamination Dusty-Environment Terminals★
- Wrong Core Used in Multi-Core Cable Spare-Core Misuse★
- Terminal Spring Relaxation Causing Open Circuit Long-Term Heavy-Load Terminal★
Calibration (50 cases)
Environmental Protection, Temperature & Humidity (50 cases)
Communication & Bus Systems (50 cases)
Vibration & Mechanical Stress (50 cases)