Problem Description

The drag-chain bend radius is 100mm while the cable requires ≥150mm; the shield braid breaks under repeated bending and the shielding effectiveness drops from 55dB to 20dB

Root Cause

[Mechanism] A bend radius smaller than the cable's allowable value puts the outer shield braid in tension and breaks the strands; shield continuity is destroyed and shielding effectiveness drops sharply.
[Calculation] The strain ε=d/(2R)=8/(2×100)=4%> the allowable 3%, and the braid strand breakage rate rises with accumulated bending.
[Design Omission] The drag chain was not selected according to the cable's allowable radius, and shield continuity was not verified.

Corrective Solution

① Match the radius: change the drag-chain R to ≥225mm (≥ cable r150×1.5) → ε drops to 2.2% and the shield no longer breaks
② Change the cable: choose a high-flex cable with r≤67mm to match the existing chain → no need to change the chain
③ Continuity: measure shield continuity after installation (resistance <5Ω) → a broken strand means it is scrap
④ Institutionalize: make the radius a mandatory item in the selection table → gatekeeping at the source
⑤ Effectiveness test: measure the shielding effectiveness (≥50dB) → confirm by measurement
⑥ Inspection: check monthly whether the shield is broken → catch progressive breakage and replace early
⑦ Bend test: run a bend test on a sample → the nominal value is often optimistic; confirm by measurement
⑧ Maintenance: add to the monthly check list → inspect periodically