Fluid System Error Cases (1120 cases)
Each case lists the problem symptom, root cause, correct solution and a practical checklist, drawn from real machine commissioning and design reviews.
Pump Selection & Cavitation (70 cases)
Excessive Piping Resistance & Pressure Drop (70 cases)
Valve Selection & Internal Leakage (70 cases)
- Damaged Gate-Valve Sealing Faces Still Leak Internally When Shut Globe valve J41H-16★★
- Failed Check Valve Causes Reverse Flow and Pump Spin-After-Shutdown Swing check at a feed-pump outlet★★
- High-Temperature Valve Stem Packing Leaks Oil Vapor Thermal-oil control valve★★
- Eroded Seat on Globe Valve in Particle Service Leaks Internally Globe Valve★★
- Gate Valve Throttled Half-Open Cavitates and Eroded, Leaking Internally Gate Valve★★
- Hot Ball Valve Seat Thermal Deformation Causes Internal Leakage High-Temperature Ball Valve★★
- Globe Valve Misused for Throttling Eroded Over Time, Leaking Internally Globe valve J41H★★
- Soft-Sealed Gate Valve Ages and Cracks at High Temperature, Leaking Soft-Sealed Gate Valve★★
- Large-Diameter Butterfly Valve Leaks from Insufficient Seating Pressure Large-diameter butterfly valve DN1200★★
- Gate Valve Used for Throttling Eroded the Seats, Leaking Internally Process Gate Valve★★
- High-Temp Valve Without a Cooling Bonnet Leaks at the Packing 350℃ Steam Valve★★
- Globe Valve Installed Backwards Leaks Internally Globe Valve★★
- Butterfly Disc/Seat Interference Prevents Full Closure, Causing Internal Leakage Concentric butterfly valve D71X-10 DN300★★
- Ball-Valve PTFE Seat Compression Set Causes Low-Temperature Leakage Floating ball valve Q41F-16C DN50★★
- Globe Valve's High Flow Resistance Causes Excess Pressure Drop - Oversized Selection Globe valve J41H-16 DN80★★
- Safety Valve Set Too Low, Pops Prematurely and Chatter-Opens Frequently Spring safety valve A42Y-16C DN50★★★
- Regulator Outlet Pressure Drifts and is Unstable Pilot-operated pressure reducing valve Y43H-16 DN65★★
- Wrong Steam Trap Selection Blows Live Steam to Waste Thermostatic-dynamic trap CS19H-16C DN25★★
- Control-Valve Flow Characteristic Mismatched to the System Causes Oscillation Pneumatic control valve CV3000 DN100★★★
- Solenoid Coil Overheats and Burns Out, Refusing to Act 2/2-way solenoid valve 4V210-08★★
- Diaphragm-Valve Diaphragm Ruptures, Causing Internal Leak and Product Contamination Weir-type diaphragm valve G41J-10 DN80★★
- Plug Valve Lubrication Fails, It Seizes and Won't Open Lubricated plug valve X47H-16 DN50★★
- Cryogenic Valve Without a Long Bonnet Freeze-Cracks the Packing Cryogenic gate valve DZ61Y-40P DN50★★★
- Fluoroplastic-Lined Valve Delaminates, Medium Penetrates the Shell PFA-lined butterfly valve D71F4-10 DN150★★★
- Plunger Valve Too Few Seal Rings Leaks Externally Plunger valve U41S-16 DN50★★
- Gate-Valve Stem Nut Worm Trapezoidal Threads, Strips and Won't Open Outside-screw gate valve Z41H-16 DN100★★
- Check-Valve Water Hammer Causes Loud Closure Impact Noise Lift check valve H41H-16 DN80★★
- Needle Valve Throttle-Outlet Cavitation Erosion and Internal Leakage Needle valve J13W-160P DN10★★
- Three-Way Valve Installed Back-to-Front Causing Mixing and Cross-Contamination Three-way control valve T-type DN80★★
- Jacketed Valve Jacket Blocked — Steam Cannot Enter Jacketed ball valve BJQ41F-16 DN50★★
- Motorized Valve Torque Switch Failure — Over-Torque Breaking the Stem Motorized gate valve MZ941H-16 DN150★★★
- Bellows Valve Bellows Fatigue Cracking — External Leakage Bellows globe valve WJ41H-16P DN40★★★
- Air Valve Float Jammed — No Air Venting Leaves Gas in the Pipe Composite air valve CARX-16 DN50★★
- High-Pressure Valve Seat Hardfacing Spalling — Internal Leakage High-pressure globe valve J61Y-320 DN20★★★
- Rubber-Lined Valve Lining Blistering and Delamination — Internal Leakage Rubber-lined diaphragm valve G41J-10 DN65★★
- Wafer Check Valve Flange Bolts Snapped During Tightening Wafer butterfly check valve H76H-16 DN200★★
- Self-Operated Control Valve Impulse Line Blocked — Calibration Drift Self-operated pressure control valve ZZY-16 DN50★★
- Ceramic Trim and Seat Cracking — Medium Injection Leak Ceramic ball valve Q41TC-16 DN50★★★
- Large-Diameter Butterfly Valve Without Bypass — Excessive Actuation Torque Double-eccentric butterfly valve D342X-10 DN1200★★
- Inverted-Bucket Steam Trap Jammed — Discharges Only Steam, No Condensate Inverted-bucket steam trap FT43-16 DN25★★
- Control Valve Trim Destroyed by Cavitation at High Pressure Drop Single-seat control valve PN40 DN50★★★
- Safety Valve Spring Stiffness Mismatch Causing Chatter Spring-loaded safety valve A48Y-16C DN80★★
- Valve Handwheel Direction Fitted Back-to-Front — Misoperation Handwheel gate valve Z41H-16 DN100★★
- Fully Welded Ball Valve Not Serviceable — Internal Leak Led to Scrap Fully welded ball valve Q361F-25 DN150★★
- Soft-Seated Gate Valve Rubber Wedge Aging and Cracking Soft-seated gate valve Z45X-10 DN100★★
- Pressure Reducing Valve Outlet Pressure Rises With Flow — Reverse Action Direct-acting pressure reducing valve DN40★★
- Hydraulic Ball Valve Jammed by Contamination — Fails to Shift Hydraulic ball valve QJH-10 DN10★★
- High-Temperature Bellows Valve Losing Spring Tension — External Leak High-temperature bellows globe valve WJ41H-25P DN40★★★
- Wafer Butterfly Valve Body Cracked by Pipe Stress Wafer butterfly valve D71X-10 DN200★★
- Vacuum Valve Failing to Seal — Leaking In Air Vacuum diaphragm valve GM-1 DN25★★
- Solenoid Valve Wired With Reversed Polarity — Fails to Act DC solenoid valve 4V210-08 DC24V★★
- Butterfly Valve Rubber Seat Aging and Sticking to the Disc — Hard to Stroke Rubber-lined butterfly valve D71J-10 DN150★★
- Check Valve Undersized — Cavitation Noise Swing check valve H44H-16 DN100★★
- Globe Valve Stem Bottomed Out — Cannot Fully Open Globe valve J41H-16 DN50★★
- Pneumatic Valve Air Supply Containing Water — Rusty Cylinder Jamming Pneumatic ball valve with GT pneumatic actuator★★
- Steam Trap Undersized — Condensate Backing Up Float steam trap FT14-16 DN20★★
- Control Valve Position Feedback Failure — Loss of Control Smart control valve with positioner DN100★★★
- Safety Valve Discharge Pipe High Back Pressure — Hard to Pop Open Spring safety valve A42Y-16C DN50★★
- Plastic-Lined Valve Liner Thermal Deformation Jamming Plastic-lined ball valve Q41F-10 DN80★★
- Solenoid Pulse Valve Diaphragm Fatigue Failure Solenoid pulse valve DMF-Z-62★★
- Cryogenic Emergency Shutoff Valve Slow to Respond — Leak Cryogenic emergency shutoff valve DJ61Y-40P DN50★★★
- Nuclear-Grade Valve Missing In-Service Inspection — Internal Leak Over Spec Nuclear-grade globe valve J41H-N DN50★★★
- Loose Packing Gland on the Valve Stem Causes Leakage Valve Stem★★
- Valve Not Fully Open Causes Excessive Loss Valve★★
- Valve Seat Erosion Causes Internal Leakage Valve Seat★★
- Butterfly Valve Disc Jams During Travel Valve Disc★★
- Valve Pressure Rating Too Low for the Service Valve★★
- Weld Spatter Trapped in the Sealing Face Causes Leakage Sealing Face★★
- Valve Installed in the Reverse Direction Causes Leakage Valve★★
- Incorrect Travel Setting on the Motorised Valve Motorised Valve★★
Seal Leakage (70 cases)
Water Hammer & Pressure Surge (70 cases)
- Pump Trip Water Hammer Overpressure Bursts the Pipe Water-Supply Pump Discharge Line★★★
- Fast Valve Closure Water Hammer Tears the Expansion Joint Water Transmission Line Butterfly Valve★★★
- Steam Pipe Water Hammer — Severe Vibration and Supports Falling Off Steam Condensate Line★★
- Sudden Pump Trip Direct Water Hammer Bursts the Pipe Feed-Pump Discharge Pipe★★★
- Valve Fast Closure Direct Water Hammer — Joint Seepage Water Supply Section★★
- Siphon Priming Loss - Air-Cavity Reverse Flow Cracking the Elbow Weld Siphon Penstock★★
- Pump-Trip Water Hammer Shatters the Check Valve Feed-Pump Discharge Piping★★★
- Over-Rapid Valve Closure - Peak Exceeds Pipe Rating Long-Distance Water Pipeline★★
- Water-Column Separation Reverse-Flow Hammer Ruptures the Pipe Siphon Discharge Pipe★★
- Long-Distance Pump Trip - Hammer Ruptures the Pipe Long-Distance Transfer Pump★★★
- Wrong Check-Valve Type - Fast Closure Causes Pressure Rise Pump Discharge Check Valve★★
- Inadequate Steam-Line Warm-Up Causes Water Slugging Steam Piping★★
- Delayed Check-Valve Seating Causes Pressure Rise Centrifugal Pump IS100-80 Trip★★★
- Over-Rapid Valve Closure Causes Pressure Rise Motorized Gate Valve 6s Fast Closure★★★
- Pump Start-Up Water-Hammer Pressure Rise Horizontal Centrifugal Pump Direct Start★★
- Air Tank Cushioning Failure Causing Water Hammer Air tank, leaking intake valve★★
- Reflected Water-Hammer Waves Stacking in a Straight Pipe Straight pipe 1200m long, blind end★★★
- Water-Hammer Overpressure in a Long-Distance Water Pipeline 8km long pipeline, two-stage pumps★★★
- Water Hammer Overloading a High-Head Pump System High-head pump H=120m★★★
- Water Hammer from a Failed Slow-Closing Check Valve Slow-closing check valve, oil-cylinder leak★★
- Undersized Surge Arrester Failing to Cut the Peak Arrester volume too small★★
- Water Hammer from Improper Pressure-Tank Precharge Pressure-tank precharge wrong★★
- Water-Hammer Waves Stacking from Simultaneous Start/Stop at Multiple Points Three pump stations shut down simultaneously★★
- Water Hammer from Broken Siphon Flow Siphon pipe, inlet flow break★★
- Condensate-Induced Water Hammer in a Steam Line Steam line, condensate not drained★★★
- Water Hammer from Liquid-Column Separation and Refill Collision Low-pressure pipe, high-point hump★★★
- Negative-Pressure Wave Buckling a Thin-Wall Pipe Thin-wall stainless steel pipe, negative pressure★★
- Flange Gasket Blown Out by Water Hammer Flange joint, shutdown hammer★★
- Branch Pipe Burst by Water Hammer Branch pipe DN50 thin wall★★
- Water Hammer Not Eliminated by VFD Soft Pump Stop VFD pump, deceleration too fast★★
- Water Hammer from Backflow into a Stopped Pump Low sump, backflow★★
- Water Hammer from Accumulated Air at a Pipe High Point High-point air pocket, start-up hammer★★
- Water Hammer from Valve Oscillation Control valve, oscillating closure★★
- Water Hammer from a Failed Check Valve Causing Backflow Check valve disc stuck open★★
- Water Hammer in Series-Connected Long-Distance Pump Stations Two pump stations in series★★★
- Water Hammer from Wrong Valve-Closing Sequence Two valves, upstream closed first★★
- Water Hammer from Abrupt PRV Closure PRV stuck fully closed★★
- Water Hammer from Fire Pump Startup Fire pump XBD direct start★★★
- Water Hammer in a Boiler Feed Pump System Feed pump DG high pressure★★★
- Elbow Cracked by Water-Hammer Wave Stress Elbow under impact stress★★
- Bladder-Type Surge Arrester Failure from Burst Bladder Bladder-type arrester, burst bladder★★
- Pressure Gauge Ruined by Water Hammer Pressure gauge, no buffering★★
- Water Hammer from Abrupt Air-Vent Closure Air vent sudden closure★★
- Water Hammer from Trapped Air in a Hump Pipe Pipeline hump, trapped air★★
- Two-Phase Steam-Water Water Hammer Steam-containing pipe, water hammer★★★
- Water Hammer Coupled with Piping-System Resonance Piping Natural Frequency Near Hammer★★★
- Pipe Natural Frequency Near the Water-Hammer Frequency Long-Span Pipe Low Frequency★★
- Unzoned Water-Hammer Protection Single Protection for Whole System★★
- Water Hammer in the Elevated-Tank Inlet Pipe Elevated-Tank Inlet Hammer★★
- Rapid Solenoid-Valve Cycling Causes Water Hammer Solenoid Valve Second-Level Cycling★★
- Piston-Pump Pulsation Water Hammer Reciprocating Pump Pulsating Flow★★
- Omitted Water-Hammer Simulation - Hidden Hazard Missed Design Without Simulation★★
- Water Hammer Causes Expansion-Joint Dislodgement Expansion Joint Pulled Apart★★
- Water Hammer After a Pump Runs Dry Then Takes In Liquid Pump Running Empty Then Admitting Liquid★★
- Valve Internal Leakage Causes Accumulated Water Hammer Isolation Valve Internal Leakage★★
- Blind-End Valve Group Water Hammer Blind-End + Valve Combination★★
- Gravity-Flow Valve-Shutdown Water Hammer Gravity Line Valve Closure★★
- Water Hammer Shattering Check-Valve Disc Check Valve Shattered by Hammer★★
- Cryogenic Liquid-Nitrogen Pipe Water Hammer Liquid-Nitrogen Pipe -196℃★★★
- Siphon-Break Water Hammer Siphon Flow Break★★
- Breathing-Valve Failure Water Hammer Protective Breather Valve Stuck★★
- Pump-Shutdown Cavitation with Water Hammer Pump-Shutdown Cavitation + Hammer★★★
- Unprotected Water Hammer on Pump Shutdown Pump Discharge★★★
- Quick-Shutdown Valve Water Hammer Quick-Closing Valve★★
- Check-Valve Slamming Water Hammer Check Valve★★
- Pipe High-Point Water Hammer Pipe High Point★★
- Condensate Water Hammer Condensate Pipe★★★
- Pump-Startup Water Hammer Pump★★
- Valve Quick-Closure Water Hammer Valve★★
- No Surge Vessel — Water Hammer Surge Tank★★
Two-phase Flow & Air Lock (70 cases)
Filter Clogging & Contamination (70 cases)
- Clogged Hydraulic Return-Line Filter, Bypass Open, Contaminants in System Hydraulic System Return-Line Filter Element★★★
- Y-Strainer 60% Clogged, Insufficient Cooling Flow Cooling-Water Y-Strainer★★
- Ruptured Precision Filter Element, Oil Content Over Limit Compressed-Air Precision Filter★★
- Clogged Element, High Δp, Bypass Open, System Contaminated Hydraulic Return-Line Filter★★
- Coarse Suction-Filtration Rating, Pump Wear, Internal Leakage Hydraulic Suction Filter★★
- Failed Air-Supply Filter Element, Dust Damages Cylinder FRL Air Filter★★
- Coarse Suction-Filter Rating Causing Pump Wear Hydraulic Suction Strainer★★
- Y-Strainer Oversized Mesh Frequent Plugging Steam Y-Strainer★★
- Improper Duplex Strainer Switching Causing Flow Interruption Duplex Lubricating-Oil Filter★★
- Clogged Breather Element on Hydraulic Tank Causing Pump Cavitation Hydraulic Tank Breather★★
- Failed Δp Indicator and Unchanged Element Causing Blockage Hydraulic Return Filter★★
- Y-Strainer Without Bypass Causing Shutdown for Cleaning Process Y-Strainer★★
- Over-Fine Suction Strainer Mesh Causing Pump Starvation Hydraulic Power-Unit Suction Strainer 100 Mesh★★
- Backward-Installed Y-Strainer Causing Binding Y-Strainer DN50★★
- Self-Cleaning Filter Backwash Time Too Short Self-Cleaning Filter DN200★★
- Lubricating-Oil Element Overdue and Plugged Solid Lubricating-Oil Element 10μm★★★
- Baghouse Filter Broken Bag Leaking Particles Bag Filter 25μm★★★
- Duplex Strainer Switching-Valve Internal Leakage Duplex Strainer DN80★★
- Magnetic Filter Saturated Without Cleaning Magnetic Filter Permanent Magnet★★
- Gummed Gas-Solid Filter Bags with High Δp Gas-Solid Dust-Removal Bag Polyester★★
- Water Filter Biofouling Blockage Water Filter 50μm★★
- High-Temperature Filter Material Failure and Perforation High-Temperature Filter 304★★★
- Uneven Flow Distribution in Parallel Filters Parallel Filters 2 Units★★
- Candle Filter Back-Pulse Pressure Insufficient Candle Filter Porous★★
- Ceramic Element Cracking During Regeneration Firing Ceramic Element 1μm★★
- Hydraulic Return Filter Clogged and Pressurized Hydraulic Return Filter 20μm★★★
- Fuel Filter Low-Temperature Icing Fuel Filter 30μm★★
- Paint Filter Particles Clogging the Spray Gun Paint Filter 100 Mesh★★
- Pharmaceutical Sterilizing-Grade Filter Integrity Failure Sterilizing-Grade Filter 0.22μm★★★
- Compressed-Air Oil-Removal Element Failure Compressed-Air Oil-Removal Element★★
- Coolant Chip Filter Clogging Coolant Filter 50μm★★
- Natural-Gas Filter Liquid Accumulation and Freeze-up Natural-Gas Filter DN100★★
- Seawater Filter Marine Biofouling Seawater Screen Filter★★
- Hydraulic Oil/Water Separation Element Saturation Hydraulic Oil/Water Separation Element★★
- Powder-Conveying Filter Weak Pulse Cleaning Powder-Conveying Filter 2μm★★
- Boiler Feedwater Filter Iron-Oxide Fouling Boiler Feedwater Filter 10μm★★
- Air-Compressor Inlet Filter Dust Clogging Air-Compressor Inlet Filter★★
- Circulating-Water Side-Stream Filter Excessive Backwash Water Use Circulating-Water Side-Stream Filter 200t/h★★
- Injection-Molding Mold-Temperature-Controller Filter Calcium Scaling Mold-Temperature-Controller Filter 50μm★★
- Lubricating-Oil Differential-Pressure Switch False Trip Lube-Filter Differential-Pressure Switch★★
- Food-and-Beverage Filter Inadequate CIP Cleaning Food Filter 5μm★★
- Gas Filter Paper Moisture-Induced Burst Gas Filter Glass-Fiber Paper★★
- High-Viscosity-Media Filter Insufficient Heating and Freeze Plugging High-Viscosity-Media Filter 100μm★★
- Mine Dust-Collector Filter Bag Abrasion and Rupture Mine Dust-Collection Filter Bag (Polyester)★★
- Resin Trap Filter Broken-Bead Clogging Resin Trap Filter 0.1mm★★
- Acid Filter Corrosion Perforation Acid Filter (Polypropylene)★★
- Slurry Filter Settling Blockage Slurry Filter 200μm★★
- Steam Filter Poor-Drainage Water Hammer Steam Filter DN50★★
- Cooling-Tower Packing-Debris Filter Blockage Cooling-Tower Circulating Filter 80μm★★
- Painting-Robot Paint-Sludge Blockage Painting-Robot Filter 50μm★★
- Dialysis-Water Filter Endotoxin Overrun Dialysis-Water Filter 0.1μm★★★
- Coolant Magnetic-Chip Undischarged Pump Damage Coolant Filter Magnetic Separator★★
- Fuel Filter Water-Emulsification Blockage Fuel Filter 30μm★★
- Gas Manifold Filter Ice Blockage Gas Manifold Filter★★
- Emulsion Filter Soap-Precipitation Blockage Emulsion Filter 25μm★★
- Beer Diatomaceous-Earth Filter Uneven-Precoat Leak Beer Diatomaceous-Earth Filter★★
- Hydraulic Suction Filter Mesh Breakage Chip Intake Hydraulic Suction Filter 80 Mesh★★★
- Pure-Water RO Cartridge Filter Fouling Pure-Water RO Cartridge Filter 5μm★★
- Vacuum Cleaner Filter Breathability Loss Weak Suction Vacuum Cleaner Filter Nonwoven★★
- Spray-Dryer Exhaust Filter Dew-Point Blinding Spray-Dryer Exhaust Filter★★
- Ink Filter Pigment-Agglomeration Blockage Ink Filter 100 Mesh★★
- Fermenter Air Filter Incomplete-Sterilization Contamination Fermenter Air Filter 0.2μm★★★
- Filter Mesh Too Fine Blockage Filter Mesh★★
- Filter Without Bypass Filter★★
- Cartridge Differential Pressure Not Monitored Filter Cartridge★★
- Filter Installed Backwards Filter★★
- Strainer Mesh Mechanical Damage Strainer Mesh★★
- Magnetic Filter Failure Magnetic Filter★★
- Filter-Shell Liquid Accumulation Filter★★
- Self-Cleaning Filter Not Put Into Service Self-Cleaning Filter★★
Heat Exchanger Fouling & Poor Heat Transfer (70 cases)
Hydraulic Contamination & Creep (70 cases)
Uneven Flow Distribution (70 cases)
Level Control Failure (70 cases)
Pipe Support & Thermal Expansion (70 cases)
Throttling Noise & Vibration (70 cases)
Siphon & Backflow (70 cases)
Vessel Strength & Insufficient Wall Thickness (70 cases)
Other (70 cases)