Knowledge Base › Fluid Systems Error Case › Downstream Water Hammer Noise

Downstream Water Hammer Noise

E44-885 · Throttling Noise and Vibration · Downstream pipe · ★★★

Problem Description

Valve closure caused water hammer with Δp=1.0MPa, and the surge noise reached 92dB(A)

Root Cause

[Mechanism] Rapid valve closure converts the liquid momentum into a water-hammer pressure wave that strikes the pipe wall and radiates sound.
[Calculation] Δp=ρcΔv=1000×1200×0.83=1.0MPa surges through the piping.
[Design Omission] No slow closure, no closure-speed verification, no buffer.

Corrective Solution

1) Close the valve slowly to prevent surge (closure time ≥20s, slow-closing valve), since the original fast closure gave Δp1.0MPa and 92dB(A) surge noise, thus slow closure reduces the hammer;
2) Verify the closure rate (rate of change ≤0.1m/s), since too fast hammers and verification slows it, thus checking the rate;
3) Add a buffer tank (outlet buffer cuts the pressure wave), since a sudden change hammers and the tank cuts it, thus buffering;
4) Switch to a slow-closing valve (slow-closing type), since a hard closure hammers and replacement is gentle, thus changing the valve;
5) Monitor the hammer state (measure the pressure wave, alarm >0.6MPa), since growing hammer approaches cracking, thus early detection;
6) Run a hammer test (quick close and measure Δp), since the lack of testing left the hammer undetected and the test reveals the wave amplitude, thus testing the hammer;
7) Control the flow to steady the speed (limit the rate), since changing conditions cause hammer and control steadies it, thus controlling speed;
8) Write the slow closure and speed verification into the specification, since the original lack of slow closure is the root cause of hammer and locking it in closes the loop, thus controlling it in the spec.

Checklist

Reference

GB/T 20801.3-2020 Design code for industrial metallic piping