A hydraulic system is essentially a “thermal power plant” — of the pressurised oil the pump delivers, part does useful work while all the remaining energy turns into heat. Once the oil temperature exceeds 60℃ the seals age, the oil oxidises and faults become frequent. If the heat generation is not calculated accurately and the cooling is not matched, even an excellent system will not survive a summer. Below, with one fixed-displacement pump system, we settle the heat power, the tank cooling capacity, the temperature rise check and the cooler selection in one pass.
Fixed-displacement pump: displacement V = 40 mL/r, speed n = 1450 r/min, working pressure p = 10 MPa, overall pump efficiency η = 0.85, volumetric efficiency ηv = 0.95.
Tank capacity 500 L, ambient temperature 25℃, allowable oil temperature 55℃ (temperature rise ΔT = 30℃), well-ventilated tank.
Find: the pump input power, the system heat power, the tank cooling area, the natural cooling capacity, and verify whether a cooler is required.
First calculate the actual flow (discounting the volumetric efficiency), then the input power — this is the electricity the system “swallows”.
The effective output power of the system is about 3 kW, and the remaining 7.8 kW (about 72%) all turns into heat. The main sources of heat are overflow loss, throttling loss, line and local pressure losses, and mechanical and volumetric losses.
A 500 L tank is 0.5 m³; with good ventilation take the heat transfer coefficient K = 15 W/(m²·℃) and the temperature difference ΔT = 55 − 25 = 30℃. The natural cooling of the tank is only 1.85 kW, which is far from enough.
With natural cooling from the tank alone, the temperature rise would reach 127℃, far above the allowable 30℃, so forced cooling is essential.
With the 8 kW air-cooled cooler fitted, the oil temperature can be held reliably below 55℃.
| Heat source | Typical share | Notes |
|---|---|---|
| Overflow loss | 20~40% | The surplus flow overflows back to the tank at the relief valve set pressure |
| Throttling / speed control loss | 10~30% | Differential pressure losses across the throttle valve and flow control valve |
| Line and local losses | 5~15% | Pressure losses in pipes, bends and fittings |
| Mechanical and volumetric losses | 10~20% | Pump / motor friction and leakage |
| System type | Recommended oil temperature | Maximum allowable |
|---|---|---|
| General industrial hydraulic system | 30~55℃ | 60℃ |
| Precision / servo system | 40±2℃ | 50℃ |
| Mobile machinery (construction machinery) | 40~65℃ | 80℃ (short term) |
1. Pump input power:
2. System heat power:
3. Tank cooling area (empirical formula):
4. Cooling power:
5. Thermal balance check:
| Symbol | Meaning | Unit | Value notes |
|---|---|---|---|
| Pin | Pump input power | kW | p·q/(60η) |
| Pheat | System heat power | kW | Input − effective output |
| K | Tank heat transfer coefficient | W/(m²·℃) | Poor ventilation 8~9, good ventilation 15~17, air cooled 23, water cooled 110~175 |
| A | Tank cooling area | m² | 6.5·V2/3 |
| ΔT | Temperature difference between the oil and the ambient | ℃ | Normally 25~35℃ |
| Method | Heat transfer coefficient K (W/m²·℃) | Characteristics | Applicable |
|---|---|---|---|
| Natural tank cooling | 8~17 | Simplest structure, zero cost | Low power (<3 kW of heat) |
| Air-cooled cooler | about 23 | No cooling water, easy to maintain | Medium power (3~20 kW) |
| Water-cooled cooler | 110~175 | Strong cooling, requires cooling water | High power (>20 kW) |
| System type | Tank capacity (multiple of the pump flow) |
|---|---|
| Fixed equipment (industrial) | (5~8) × qpump |
| Mobile machinery (construction machinery) | (2~3) × qpump |
| High heat generation / continuous operation | 8~10 × qpump |
| # | Common error | Consequence | Correct practice |
|---|---|---|---|
| 1 | Omitting the overflow and throttling losses from the heat generation | The actual heat generation far exceeds the estimate and the oil temperature soars | Calculate the heat power as Pin−Pout or ηsys on a full-consumption basis |
| 2 | Misusing the tank cooling area formula (wrong unit for V) | The area comes out too large and the cooling capacity is falsely high | V must be converted to m³, A = 6.5·V2/3 |
| 3 | Taking the ambient temperature as room temperature with no margin | The cooling is insufficient on a 40℃ summer day | Take ΔT from the ambient temperature of the worst season |
| 4 | Still relying on natural cooling when the heat generation is high | Excessive oil temperature, ruined seals and degraded oil | A cooler is mandatory above 3 kW |
| 5 | Sizing the cooler power exactly equal to the heat generation | There is no margin, so the limits are exceeded once the cooling performance degrades | Pcooler ≥ (1.3~1.5) × the calculated shortfall |