The most time-consuming part of recommending a scheme is not the calculation but the comparison. For the same ratio, belt drive, chain drive, gears, worm gear and cycloidal drive can each be sized, but which one should actually be used? Guessing from experience tends to miss the knock-on effects on efficiency, heat dissipation and cost. Below we work through a conveyor drive case and then expand into the scoring formula.
A belt conveyor drive: motor power P = 7.5 kW, input speed n₁ = 1450 r/min, drum output speed n₂ = 58 r/min.
Constraints: compact structure, medium accuracy, low noise, low cost, and no self-locking required.
Keep this 25 in mind, because it is the first threshold behind every later judgement. The ratio is not an option to be chosen — it is a filter.
Tabulate the single-stage ratio limits of the 12 transmission types and cut with i = 25 directly:
| Transmission form | Single-stage ratio range | Can i=25 be done in one stage |
|---|---|---|
| Flat belt drive | 1 ~ 5 | ✗ far too small |
| V-belt drive | 1 ~ 7 | ✗ |
| Timing belt drive | 1 ~ 10 | ✗ |
| Roller chain drive | 1 ~ 8 | ✗ |
| Spur cylindrical gear | 1 ~ 8 | ✗ |
| Helical cylindrical gear | 1 ~ 10 | ✗ |
| Bevel gear | 1 ~ 5 | ✗ |
| Planetary gear reducer | 3 ~ 12 | ✗ |
| Harmonic drive | 30 ~ 300 | ✗ the lower limit of 30 is out of reach |
| Friction wheel drive | 1 ~ 6 | ✗ |
| Worm gear | 5 ~ 80 | ✓ |
| Cycloidal drive | 11 ~ 100 | ✓ |
After one round of screening only two candidates remain: the worm gear and the cycloidal drive. This step eliminates ten schemes without calculating a single tooth profile.
Both can do it in one stage, so what do we compare? The efficiency, because efficiency converts directly into heat and electricity cost.
| Scheme | Efficiency η | Loss power = P(1−η) | Output torque T₂ = 9550Pη/n₂ |
|---|---|---|---|
| Worm gear | 0.70 | 2.25 kW | 864.4 N·m |
| Cycloidal drive | 0.90 | 0.75 kW | 1111.4 N·m |
A difference of 1.5 kW. At two shifts a day and 8000 h a year, that is 12000 kWh extra per year. More importantly, all 2.25 kW becomes heat inside the housing, and the heat exchanger, the oil temperature and the lubricant life all deteriorate with it.
Beyond the ratio and the efficiency there are four soft constraints: center distance, accuracy, noise and cost. Use a 100-point base and deduct item by item; the final figure is the score.
| Deduction item | Rule |
|---|---|
| Ratio out of range | Below the lower limit or above the upper limit, −30 (deducted only once) |
| Center distance mismatch | Compact is required but the scheme is not compact → −25; moderate is required but the scheme is "far" or "compact" → −10 |
| Insufficient accuracy | High accuracy required but the scheme is "low" → −30; it is "medium" → −15 |
| Noise above the limit | Low noise required but the scheme is "medium" → −20; it is "high" → −40 |
| Cost over budget | Low cost required but the scheme is "high" → −35; it is "medium" → −15 |
| Missing self-locking | Self-locking required but the scheme cannot self-lock → −50 |
| Efficiency bonus | η ≥ 0.95 adds 5 points; η < 0.80 deducts a further 10 |
Substituting this example (compact, medium accuracy, low noise, low cost, no self-locking):
| Scheme | Ratio | Center distance | Cost | Efficiency | Score |
|---|---|---|---|---|---|
| Cycloidal drive | ✓ 0 | ✓ compact 0 | medium −15 | +0 | 85 |
| Worm gear | ✓ 0 | near −25 | medium −15 | −10 | 50 |
| Helical cylindrical gear | ✗ −30 | near −25 | medium −15 | +5 | 35 |
| Timing belt drive | ✗ −30 | medium −25 | medium −15 | +5 | 35 |
| V-belt drive | ✗ −30 | far −25 | low 0 | +0 | 45 |
The cycloidal drive loses only 15 points on cost and passes everything else, so it tops the table with 85 points.
Cycloidal drive: T₂ = 9550 × 7.5 × 0.90 / 58 = 1111.4 N·m
A conveyor has a uniform load but with impact, so take the duty factor KA = 1.25:
The rated output torque of the reducer selected must be ≥ 1400 N·m; do not simply keep your eye on 1111.
If the plant only builds gearboxes and will not accept a cycloidal drive, go with two-stage helical gears. Split the ratio by the expanded formula i₁ ≈ 1.35 i₂:
Verification: 5.81 × 4.30 = 24.98, which differs from 25.0 by 0.08% — acceptable.
Overall efficiency: η = 0.98 × 0.98 × 0.99 = 0.9508, with a loss of only 0.37 kW, the most economical of the three schemes.
The cost is: a two-stage housing, two gear pairs, four shafts, twice as many parts, an axial length about 40% longer than the cycloidal drive, and both the cost and the number of maintenance points go up.
| Scheme | Score | Efficiency | Loss | Conclusion |
|---|---|---|---|---|
| Cycloidal drive | 85 | 0.90 | 0.75 kW | First choice, one stage, compact, impact resistant |
| Two-stage helical gears | 35 (single-stage basis) | 0.951 | 0.37 kW | Best efficiency, high cost and size penalty |
| Worm gear | 50 | 0.70 | 2.25 kW | Only when self-locking is required |
This example does not need self-locking, so the worm's only advantage cannot be used and the 2.25 kW of loss is pure burden. Select the cycloidal drive with a rated torque ≥ 1400 N·m.
The precondition for the scoring to work is that the capability boundaries of each transmission are laid out clearly first. The table below gives the single-stage capability and characteristics of the 12 commonly used transmissions:
| Scheme | Ratio | Efficiency | Applicable power | Center distance | Accuracy | Noise | Cost | Self-locking |
|---|---|---|---|---|---|---|---|---|
| Flat belt drive | 1~5 | 0.94 | Medium ≤50kW | Far | Low | Low | Low | No |
| V-belt drive | 1~7 | 0.92 | Medium ≤100kW | Far | Low | Low | Low | No |
| Timing belt drive | 1~10 | 0.98 | Medium ≤50kW | Medium | High | Low | Medium | No |
| Roller chain drive | 1~8 | 0.96 | Medium ≤150kW | Medium | Medium | Medium | Low | No |
| Spur cylindrical gear | 1~8 | 0.97 | Large ≤500kW | Near | High | Medium | Medium | No |
| Helical cylindrical gear | 1~10 | 0.98 | Large ≤500kW | Near | High | Low | Medium | No |
| Bevel gear | 1~5 | 0.95 | Medium ≤200kW | Near | Medium | Medium | Medium | No |
| Worm gear | 5~80 | 0.70 | Small ≤30kW | Near | Medium | Low | Medium | Yes |
| Planetary gear reducer | 3~12 | 0.97 | Large ≤500kW | Compact | High | Medium | High | No |
| Harmonic drive | 30~300 | 0.85 | Small ≤5kW | Compact | Extremely high | Low | High | No |
| Cycloidal drive | 11~100 | 0.90 | Medium ≤50kW | Compact | High | Low | Medium | No |
| Friction wheel drive | 1~6 | 0.88 | Small ≤10kW | Medium | Low | Low | Low | No |
For a multi-stage cascade: itotal = i₁ × i₂ × … × in
Input torque: T₁ = 9550 · P / n₁. Note that η appears in the numerator of T₂ — the lower the efficiency, the lower the output torque, and this is an item many people miss.
For a multi-stage drive: ηtotal = η₁ · η₂ · … · ηbearing · ηcoupling. A pair of rolling bearings is about 0.99, a coupling about 0.99 and a gear mesh 0.97~0.98.
Giving the high-speed stage the larger ratio brings the diameters of the two large gears closer together, so the oil immersion depth is consistent and the housing is more compact. For a coaxial arrangement take i₁ ≈ i₂.
Take the top 5 in descending score order as the shortlist of candidate schemes.
| Load characteristic | Typical equipment | KA |
|---|---|---|
| Uniform load | Generators, fans, smooth conveyors | 1.00 ~ 1.25 |
| Moderate impact | Belt conveyors, mixers, machine tool feeds | 1.25 ~ 1.50 |
| Heavy impact | Crushers, hoists and lifts, rolling mills | 1.50 ~ 2.00 |
| Transmission form | Recommended i | Limit imax |
|---|---|---|
| V-belt drive | 2 ~ 5 | 7 |
| Timing belt drive | 1 ~ 6 | 10 |
| Roller chain drive | 2 ~ 5 | 8 |
| Spur / helical cylindrical gear | 3 ~ 6 | 8 / 10 |
| Planetary gear (NGW) | 3 ~ 9 | 12 |
| Cycloidal drive | 11 ~ 59 | 100 |
| Worm gear | 10 ~ 40 | 80 |
| Harmonic drive | 50 ~ 160 | 300 |
| Efficiency band | Schemes | Typical η |
|---|---|---|
| High efficiency (≥0.95) | Timing belt, helical gears, spur gears, chain, planetary | 0.96 ~ 0.99 |
| Medium efficiency (0.85~0.95) | V-belt, flat belt, bevel gears, cycloidal drive, friction wheel | 0.88 ~ 0.94 |
| Low efficiency (<0.85) | Worm gear, harmonic drive | 0.70 ~ 0.85 |
| Wrong practice | Consequence | Correct practice |
|---|---|---|
| Looking only at whether the ratio can be achieved and not at the efficiency | The worm scheme handles i=25 in one stage, but 2.25 kW becomes heat, causing summer oil temperature alarms and ageing of the seals | Compare the efficiency as soon as the ratio screen is done, converting the loss power into a heat load |
| Scoring a multi-stage scheme on the single-stage basis | The helical gear loses 30 points for exceeding the single-stage limit of i=25 and is eliminated outright, even though two stages in series works perfectly well | Screen with the single-stage capability first, then rescore the schemes that need several stages separately |
| Forgetting to apply the duty factor | Selecting on 1111 N·m while the actual impact torque exceeds 1389, giving early pitting of the tooth flanks | Tc = KA·T₂, then select the rated torque |
| Ignoring the cooling capability | Calculating only the strength and not the heat, and only after the housing is fitted is it found that oil cooling is required | Ploss = P(1−η), then check the natural cooling area of the housing or add a fan |
| Splitting the ratio equally over two stages | The diameters of the two large gears differ too much for oil immersion lubrication, and the high-speed stage bearings are loaded off-center | Take i₁ ≈ 1.35 i₂ with the expanded formula; take i₁ ≈ i₂ for a coaxial arrangement |
| Believing a harmonic drive can self-lock | The load drives the mechanism backwards after a power failure and the lifting mechanism drops | A harmonic drive is a rigid transmission and does not self-lock; a brake must be added. Self-locking comes only from a small lead angle worm or a brake |