Worm gearing has low efficiency and generates a lot of heat — every engineer knows this. But how much heat is generated, will the oil temperature exceed the limit, and is a cooling fan or a water-cooled coil needed? At this step many people simply go by feel. The result? Either a fan is fitted that was never needed, or the oil temperature soars into the nineties and the drive fails by adhesive wear. Below we calculate through one example and then expand into the formulas and the cooling design.
A worm gearbox with an input power of 5.5 kW, a transmission efficiency of 72% and a housing cooling surface area of 0.85 m². The ambient temperature is 25°C and the permissible oil temperature is 85°C. Verify whether additional cooling is required.
Heat generation = input power × (1 − efficiency):
Of the 5.5 kW delivered by the motor, 1.54 kW becomes frictional heat, and this heat must be dissipated through the housing.
At thermal equilibrium, heat generated = heat dissipated. With natural cooling, the heat dissipated equals the housing heat transfer coefficient × the cooling area × the temperature difference between the oil and the ambient:
Take the natural cooling heat transfer coefficient k_s = 12 W/(m²·°C) and A = 0.85 m²:
Oil temperature = 25°C + 151°C = 176°C, far above the permissible 85°C!
Increasing the housing cooling area is the most direct passive cooling method. Work backwards from the permissible oil temperature t_o ≤ 85°C to find the area required:
The existing 0.85 m² is far from sufficient; cooling fins must be added or the housing enlarged beyond 2.14 m². If space is tight, this scheme is not realistic.
With a fan fitted, the heat transfer coefficient k_s can rise to 20~30 W/(m²·°C). Take k_s = 25 W/(m²·°C):
Oil temperature = 25°C + 72.5°C = 97.5°C, still above the 85°C limit.
Increase the housing area moderately (by adding cooling fins) and combine it with the fan:
Oil temperature = 25°C + 51.3°C = 76.3°C ✅ below 85°C
Worm gearing is dominated by sliding friction and its mesh efficiency is typically only 50%~85%, meaning 15%~50% of the input power becomes heat. If that heat cannot be removed the oil temperature keeps rising, which leads to:
| Cooling method | Heat transfer coefficient k_s (W/m²·°C) | Application scenario | Cost |
|---|---|---|---|
| Natural cooling (no fan) | 8~15 | P_v < 1 kW, low speed and light load | Low |
| Fan cooling (shaft-mounted fan) | 20~30 | Medium power, limited housing space | Medium |
| Water cooling (coil / jacket) | 30~60 | High power, continuous operation, high ambient temperature | High |
Heat generation:
Heat balance equation:
k_s — housing heat transfer coefficient, W/(m²·°C); A — effective housing cooling area, m²; t_o — oil temperature, °C; t_a — ambient temperature, °C
Oil temperature calculation:
Verification condition:
[t] — permissible oil temperature, normally 80~85°C for mineral oil and 90~95°C for synthetic oil. Above 100°C, forced cooling is mandatory.
Required cooling area (backward calculation):
| Center distance a (mm) | Housing cooling area A (m²) | Permissible input power with natural cooling (kW) |
|---|---|---|
| 80 | 0.15~0.25 | 0.4~0.8 |
| 100 | 0.25~0.40 | 0.8~1.5 |
| 125 | 0.40~0.60 | 1.5~2.5 |
| 160 | 0.60~0.90 | 2.5~4.0 |
| 200 | 0.85~1.20 | 4.0~6.0 |
| 250 | 1.20~1.80 | 6.0~10 |
| Condition | k_s range (W/m²·°C) | Description |
|---|---|---|
| Natural cooling, clean indoor environment | 8~10 | Poor air flow, so take the lower end of the range |
| Natural cooling, with a light breeze | 12~15 | Typical workshop conditions |
| Shaft-mounted fan | 20~25 | The fan is mounted at the end of the worm shaft |
| Separate high-flow fan | 25~30 | A dedicated cooling fan unit |
| Water-cooled coil in the oil sump | 30~45 | A cooling water circulation loop is required |
| Water-cooled jacket | 40~60 | Highly effective cooling, complex structure |
| No. | Common mistake | Consequence | Correct practice |
|---|---|---|---|
| 1 | Checking the strength but not the thermal balance | The strength passes while the oil temperature exceeds 100°C and the drive fails by adhesive wear | Worm gearing always requires both a strength check and a thermal balance check |
| 2 | Counting only the housing outline as the cooling area | The effectiveness of the cooling fins and the base is overlooked | For a finned housing, use the developed area × 0.8, and do not count the base contact face |
| 3 | Taking k_s too large | The calculated oil temperature looks fine but the actual temperature soars | Take 10~12 without a fan and stay conservative; when uncertain, use the lower limit |
| 4 | The fan is fitted backwards or the air path is blocked | The fan is useless and the cooling effect is almost nil | Make sure the fan blows towards the housing cooling fins and that the airflow is unobstructed |
| 5 | Ignoring a high ambient temperature | In a workshop at 40°C in summer the oil temperature easily exceeds the limit | Always verify against the worst case (the highest summer ambient temperature) |
| 6 | Using water cooling but with a supply temperature that is too high | The cooling water warms up as it passes through the coil and the effect is degraded | Inlet water temperature ≤ 25°C, outlet temperature ≤ 40°C, and ample flow rate |