When angular contact ball bearings and tapered roller bearings carry a radial load, they simultaneously generate an internal axial force. Get this axial force wrong and the whole bearing selection falls apart. Below we work through a complete case and then expand into the formulas and the parameter selection principles.
Duty condition: the high-speed shaft of a reducer uses a pair of 7206C angular contact ball bearings (face-to-face mounting, that is a DF arrangement). The radial loads on the bearings are Fr₁ = 1800 N and Fr₂ = 1200 N, there is an additional axial force Ka = 800 N, and the contact angle is α = 15°.
For angular contact ball bearings, at α = 15° we have e = 0.38 (from the handbook).
When Fa/Fr ≤ e, the internal axial force is Fs = e × Fr
Fs₁ = 0.38 × 1800 = 684 N
Fs₂ = 0.38 × 1200 = 456 N
Face-to-face mounting (DF arrangement): the Fs of the two bearings act towards each other (pointing at one another).
Compare Fs₁ with Fs₂ + Ka:
Fs₁ = 684 N, Fs₂ + Ka = 456 + 800 = 1256 N
684 < 1256 → the shaft tends to move to the right (towards bearing 2)
Bearing 1 (the "tightened" end): Fa₁ = Fs₂ + Ka = 456 + 800 = 1256 N
Bearing 2 (the "relaxed" end): Fa₂ = Fs₂ = 456 N
Rule:the relaxed bearing takes its own Fs, while the tightened bearing takes the Fs from the other side plus the external axial force.
Bearing 1: Fa₁/Fr₁ = 1256/1800 = 0.698 > e (=0.38) → the X and Y coefficients are needed
Bearing 2: Fa₂/Fr₂ = 456/1200 = 0.38 ≤ e (=0.38) → X=1, Y=0
From the table: when Fa/Fr > e, X = 0.44 and Y = 1.47 (for α = 15°)
P = X·Fr + Y·Fa
P₁ = 0.44 × 1800 + 1.47 × 1256 = 792 + 1846 = 2638 N
P₂ = 1 × 1200 + 0 × 456 = 1200 N
Conclusion:the equivalent load on bearing 1 (the side carrying the external axial force) is far greater than on bearing 2, so P₁ = 2638 N should be used as the basis for the life calculation.
Bearing basic dynamic load rating C = 28500 N (from the table), speed n = 1450 r/min:
L₁₀ = (C/P)^ε × 10⁶ / (60n) = (28500/2638)³ × 10⁶ / (60×1450) = 1263 × 10⁶ / 87000 ≈ 14520 hours
This meets the 10000 hour life required of the reducer ✓
✅ A pair of 7206C angular contact ball bearings, mounted face-to-face (DF)
✅ Fa₁ = 1256 N, Fa₂ = 456 N
✅ Equivalent dynamic loads P₁ = 2638 N, P₂ = 1200 N
✅ Calculated life L₁₀ ≈ 14520 h > 10000 h, passed
Angular contact ball bearings and tapered roller bearings share a common feature — the contact angle α ≠ 0 (commonly 15°, 25° and 40°). Under a radial load they generate an axial component, and this component must be balanced by the bearing itself or by the axial force of the other bearing.
| Mounting arrangement | Force characteristic | Application |
|---|---|---|
| Face-to-face (DF) | The axial forces of the two bearings point towards each other and bidirectional axial loads can be carried | Higher stiffness, suitable for an overhung end |
| Back-to-back (DB) | The axial forces of the two bearings act away from each other, with a large span and good resistance to overturning | Suitable for large overhung loads or large moments at the shaft end |
| Tandem (DT) | The axial forces act in the same direction and share a unidirectional axial load | Used in pairs when the axial load is very large |
When an angular contact bearing carries a radial load Fr, the contact line between the rolling elements and the raceways is inclined, which produces a tendency for the bearing to separate along the axial direction. This tendency is the internal axial force Fs. The formula is Fs = e × Fr, where e is the load factor related to the contact angle and the Fa/Fr ratio.
Parameter descriptions:
| Symbol | Meaning | Unit |
|---|---|---|
| Fr | Radial load carried by the bearing | N |
| Fa | Axial load carried by the bearing | N |
| Fs | Axial component generated inside the bearing | N |
| Ka | Externally applied axial force | N |
| e | Load factor, related to the contact angle | — |
| X | Radial dynamic load factor | — |
| Y | Axial dynamic load factor | — |
| C | Basic dynamic load rating of the bearing | N |
| P | Equivalent dynamic load | N |
| ε | Life exponent (=3 for ball bearings, 10/3 for roller bearings) | — |
| n | Bearing speed | r/min |
| Contact angle α | e value | Fa/Fr ≤ e | Fa/Fr > e |
|---|---|---|---|
| X / Y | X / Y | ||
| 15° | 0.38 | 1 / 0 | 0.44 / 1.47 |
| 25° | 0.68 | 1 / 0 | 0.41 / 0.87 |
| 40° | 1.14 | 1 / 0 | 0.35 / 0.57 |
| Tapered roller bearing | 1.5·tanα | 1 / 0 | 0.4 / 0.4·cotα |
| # | Common mistake | Consequence | Correct practice |
|---|---|---|---|
| 1 | Forgetting the internal axial force Fs | The axial load is badly underestimated and the bearing fails prematurely | Fs must always be calculated for angular contact bearings, taking the mounting arrangement into account |
| 2 | Judging the tightened and relaxed ends incorrectly | The load on the heavily loaded bearing is underestimated and the life is badly overestimated | For face-to-face mounting the Fs act towards each other, and the larger one identifies the tightened end |
| 3 | Using the axial load at the housing bore directly | The redistribution of the shaft loading caused by the mounting arrangement is ignored | Calculate Fs first, then obtain the actual Fa from the force balance |
| 4 | Looking up the X and Y coefficients in the wrong table | The equivalent load is wrong and the selection becomes dangerous | Look up the corresponding e and X/Y for the actual contact angle |
| 5 | Using a single row bearing without pairing it | The bearing cannot balance the internal axial force and simply pulls out | Angular contact bearings must be installed in pairs (DF/DB/DT) |