After a gearbox has run for a long time, the heat produced by gear meshing and bearing friction keeps raising the oil temperature. Above 85°C the lubricating oil oxidises and fails faster, the seals age, and in severe cases the gears fail by adhesive wear. Cooling calculation is therefore not an option but a mandatory gate during selection. Below we carry out a complete cooling check on a two-stage cylindrical gear reducer.
A two-stage cylindrical gear reducer with input power P_in = 22 kW, rated speed n = 1450 r/min, overall efficiency η = 0.94 and center distance a = 320 mm. Housing outline dimensions: length L = 700 mm, width W = 400 mm, height H = 350 mm. The housing is cast iron and uses natural cooling (no fan); ambient temperature t_a = 30°C and the maximum permissible oil temperature t_o = 85°C.
All the power lost in the gearbox is converted into heat:
P_v = P_in × (1 − η) = 22 × (1 − 0.94) = 1.32 kW
In other words the gearbox generates about 4752 kJ of heat per hour (1.32 kW × 3600 s), and this heat has to be dissipated from the housing surface into the air.
Estimate of the outer surface area of the housing (ignoring fins and the base):
A = 2 × (L×W + L×H + W×H) = 2 × (0.7×0.4 + 0.7×0.35 + 0.4×0.35)
= 2 × (0.28 + 0.245 + 0.14) = 2 × 0.665 = 1.33 m²
The actual effective cooling area is taken as A_eff = 0.6 × A = 0.6 × 1.33 ≈ 0.80 m² (allowing for the bottom contact face and the shielding between ribs).
Take the natural convection heat transfer coefficient α = 12 W/(m²·°C) (cast iron housing, no forced ventilation):
Q_cool = α × A_eff × (t_o − t_a) = 12 × 0.80 × (85 − 30)
= 12 × 0.80 × 55 = 528 W = 0.528 kW
Since P_v = 1.32 kW > Q_cool = 0.528 kW, the cooling is insufficient!
The oil temperature will keep rising, and the measured steady-state oil temperature will reach:
t_o = t_a + P_v / (α × A_eff) = 30 + 1320 / (12 × 0.80) = 30 + 137.5 ≈ 167.5°C
This is far above the 85°C limit, so forced cooling measures must be adopted.
Fit an axial fan at the input shaft end; take the forced air cooling heat transfer coefficient α_f = 30 W/(m²·°C):
Q_cool_f = α_f × A_eff × (t_o − t_a) = 30 × 0.80 × 55
= 30 × 0.80 × 55 = 1320 W = 1.32 kW
Since Q_cool_f = 1.32 kW ≥ P_v = 1.32 kW, the cooling satisfies the requirement!
The steady-state oil temperature is then:
t_o = 30 + 1320 / (30 × 0.80) = 30 + 55 = 85°C
This is exactly at the permissible upper limit, so it is recommended to increase the housing cooling area somewhat or fit a fan with a larger air volume to leave some margin.
The basic gearbox has a cooling area of only 0.80 m², and natural cooling cannot meet the cooling demand for a 22 kW input power. An axial fan must be fitted at the input shaft end (forced air cooling); an axial fan with an air volume of ≥800 m³/h is recommended. It is also advised to add cooling fins to the housing to raise the effective area above 1.2 m², so that the oil temperature stays within the safe band of 75~80°C.
When a gearbox runs, all the power losses (gear mesh loss, bearing friction loss, churning loss) are converted into heat energy, which raises the temperature of the lubricating oil and the housing. The essence of the cooling calculation is to establish the thermal balance equation:
Here P_v must be less than or equal to Q_cool, otherwise additional cooling measures must be taken.
| Cooling method | Applicable condition | Heat transfer coefficient α (W/m²·°C) | Cost |
|---|---|---|---|
| Natural cooling | Low power reducers (P_in ≤ 5 kW) | 8~15 | None |
| Forced air cooling with a fan | Medium power (5~50 kW) | 20~40 | Low |
| Cooling coil (water cooling) | High power (≥50 kW) or high ambient temperature | 100~300 | Medium |
| Circulating oil cooling | High power or continuous heavy-duty conditions | — | High |
| Cooling method | Housing material | Ambient condition | α (W/m²·°C) |
|---|---|---|---|
| Natural cooling | Cast iron | Indoors, no air flow | 10~14 |
| Natural cooling | Cast steel | Indoors, no air flow | 8~12 |
| Natural cooling | Aluminium alloy | Indoors, no air flow | 12~18 |
| Fan cooling | Cast iron | v=2~5 m/s | 25~40 |
| Fan cooling | Aluminium alloy | v=2~5 m/s | 30~50 |
| Water cooling coil | — | Water flow 1~2 m/s | 150~300 |
| Lubricating oil type | Maximum permissible oil temperature | Recommended working oil temperature |
|---|---|---|
| Mineral oil (L-CKC) | 90°C | 50~80°C |
| Synthetic oil (PAO) | 100°C | 60~90°C |
| Mineral oil (for worm gears) | 80°C | 40~70°C |
| Reducer type | Estimation formula | Description |
|---|---|---|
| Single-stage cylindrical gear | A ≈ 0.2 × a^1.5 | a is the center distance (mm) |
| Two-stage cylindrical gear | A ≈ 0.3 × a^1.5 | a is the low-speed stage center distance |
| Three-stage cylindrical gear | A ≈ 0.4 × a^1.5 | a is the low-speed stage center distance |
| Worm reducer | A ≈ 0.5 × a^1.5 | a is the center distance of the worm gear pair |
| Common mistake | Consequence | Correct practice |
|---|---|---|
| Using the outer envelope area of the housing directly as the effective cooling area | The cooling area is overstated, the cooling is insufficient and the oil temperature exceeds the limit | Multiply by a reduction factor of 0.5~0.7, or calculate from the actual fin area |
| Ignoring the heat from the churning loss | The total heat generation is underestimated by 10~30% | Low-speed heavy-duty reducers must include the churning loss; use a measured or experience value for η |
| Taking the heat transfer coefficient too high | The actual cooling falls short of the calculated value and the oil temperature exceeds the limit | For natural cooling do not exceed 12 W/m²·°C, and for fan cooling not more than 40 W/m²·°C |
| Taking the ambient temperature as the summer average | The oil temperature exceeds the limit in extreme hot weather | Use the highest summer ambient temperature (for example 40°C) for the check |
| Mounting the fan on the output shaft end | The output speed is low and the air volume is insufficient | The fan should be mounted on the input (high-speed) shaft end, with fan speed ≥1000 r/min |