When a servomotor drives a gearbox, there are two things to fear most: first, fixing the gear ratio by rule of thumb — choosing it just because "the speed divides down to about the right figure", and ending up with an inertia ratio over the limit and a servo whose gain cannot be tuned; second, looking at the gearbox torque only — ordering it because the rated torque is adequate, and then finding the backlash too large and the radial load over the limit, so the turntable positioning accuracy cannot be achieved. In fact the gear ratio is an interval squeezed between two constraints: inertia matching sets the lower bound and the motor speed sets the upper bound. Below we run through seven steps with a indexing turntable case, then expand into the formulas.
| Item | Value |
|---|---|
| Turntable mass m | 120 kg |
| Turntable diameter D | φ600 mm (radius r = 0.3 m) |
| Load shaft friction torque TL | 8 N·m |
| Motion requirement | Rotate 90° in 1.2 s (triangular velocity profile) |
| Working takt | Indexing 1.2 s + dwell 3.0 s, cycle 4.2 s |
| Servomotor rated speed | 3000 r/min (trial selection 400 W, JM = 0.27 × 10⁻⁴ kg·m²) |
| Planetary gearbox efficiency η | 0.95 (two stages) |
| Gearbox's own inertia Jgb | 1.5 × 10⁻⁴ kg·m² (referred to the motor shaft, two-stage catalogue value) |
Turntable inertia (homogeneous disc about its central axis):
JL = ½ · m · r² = 0.5 × 120 × 0.3² = 5.4 kg·m²
Motion requirement: 90° = π/2 rad in 1.2 s, triangular velocity profile:
α = 4θ / t² = 4 × 1.5708 / 1.44 = 4.36 rad/s²
Peak load speed ω = α · t/2 = 4.36 × 0.6 = 2.62 rad/s = 25 r/min
If the motor were coupled directly to the turntable:
Inertia ratio = JL / JM = 5.4 / (0.27 × 10⁻⁴) = 20 000 times, far above the permissible 10 ✗
Conclusion: the direct-coupled scheme is eliminated outright. A gearbox is needed to "divide down" the load inertia — the inertia referral is related to the square of the gear ratio, and this is the most underrated function of a gearbox: it is not only a torque multiplier but an inertia matching tool.
The load inertia referred to the motor shaft JL' = JL / i²; the requirement is that the ratio of the referred total load inertia to the motor inertia is ≤ 10:
(JL / i² + Jgb) / JM ≤ 10
Roughly, i ≥ √(JL / (10 · JM)) = √(5.4 / (10 × 0.27 × 10⁻⁴)) = √20000 ≈ 142
After accounting for Jgb, only i = 150 and above passes reliably — note it down for now: the lower bound of the gear ratio is about 150.
The peak load speed is 25 r/min, and the maximum working speed of the motor is controlled at 80% of rated (2400 r/min):
i ≤ n_max / n_load = 2400 / 25 = 96
With the 750 W: i ≥ √(5.4 / (10 × 0.87 × 10⁻⁴)) = √6207 ≈ 79
The interval becomes [79, 96], so there is a choice. Take the standard two-stage ratio i = 90 (i = 80/100 also exist; anything in the 70~100 range can be verified).
Referred load inertia (i = 90, Jgb = 1.6 × 10⁻⁴):
JL' = 5.4 / 90² = 6.67 × 10⁻⁴ kg·m²
Inertia ratio = (6.67 + 1.6) × 10⁻⁴ / 0.87 × 10⁻⁴ = 9.5 ≤ 10 ✓
Acceleration torque (motor shaft angular acceleration α_motor = α × i = 4.36 × 90 = 392 rad/s²):
Ta = (JL' + Jgb + JM) · α_motor = (6.67 + 1.6 + 0.87) × 10⁻⁴ × 392 = 0.36 N·m
Referred friction torque: Tf = TL / (i · η) = 8 / (90 × 0.95) = 0.09 N·m
Peak torque: Tp = Ta + Tf = 0.45 N·m (the 750 W maximum torque is 7.16 N·m, so this is only 6%) ✓
Continuous effective torque (indexing 1.2 s + dwell 3 s): Trms = √(Tp² × 1.2 / 4.2) = 0.24 N·m (rated 2.39 N·m, so 10%) ✓
Speed: 25 × 90 = 2250 r/min, which is 75% of the rated 3000 ✓
A gearbox does more than supply a ratio; four specifications have to pass:
| Verification item | Calculation | Criterion | Conclusion |
|---|---|---|---|
| Output peak torque | 0.45 × 90 × 0.95 = 38.5 N·m | ≤ gearbox peak / emergency torque | Select a T2N = 60 N·m class (φ90 two-stage) ✓ |
| Output continuous torque | 0.24 × 90 × 0.95 = 20.5 N·m | ≤ 0.7 × T2N = 42 N·m | ✓ |
| Backlash | 3 arcmin (two-stage) | Converted for turntable positioning: 3′ = 8.7×10⁻⁴ rad, a linear value of 0.26 mm at r300 mm | Meets the ±0.5 mm indexing requirement ✓ |
| Radial / axial load | The forces on the turntable shaft are calculated separately from the bearing arrangement | ≤ the permissible catalogue value (the cantilevered output shaft case must be checked carefully) | ✓ |
| Item | Confirmed value |
|---|---|
| Servomotor | 750 W (rated 3000 r/min, JM = 0.87 × 10⁻⁴ kg·m²) |
| Gear ratio | i = 90 (two-stage planetary; a standard ratio anywhere in the 80 ~ 100 range also works) |
| Inertia ratio | 9.5 ≤ 10 ✓ |
| Peak / continuous torque | 0.45 / 0.24 N·m (6% / 10% of the motor capability) ✓ |
| Working speed | 2250 r/min (75% of rated) ✓ |
| Gearbox specification | Two-stage planetary, T2N = 60 N·m, backlash ≤ 3 arcmin, efficiency 0.95 |
| Output positioning accuracy | Backlash contributes 0.026 mm (at r300 mm) ✓ |
Gearbox selection is often treated as "look up a table and pick a ratio", but in reality it is the intersection of three main lines:
| Main line | Constraint | Typical symptom when it is not satisfied |
|---|---|---|
| ① Inertia matching | (JL/i² + Jgb) / JM ≤ 10 (≤ 5 for high response) | The gain cannot be tuned, positioning overshoots, the servo oscillates |
| ② Speed matching | n_load × i ≤ 0.8 × rated speed | The machine enters field weakening at high speed, the torque collapses, the temperature rise is large |
| ③ Torque matching | Both the peak and the continuous torque ≤ 80% of the capability of the gearbox and the motor | Pitting of the gearbox tooth flanks, motor overload alarms |
Most people remember only the first. The third is the key that makes "a small motor driving a large load" possible: at i = 90, a turntable of 5.4 kg·m² referred to the motor shaft comes down to just 6.67 × 10⁻⁴ kg·m², a reduction of 8100 times.
The inertia of a two-stage planetary gearbox referred to the input shaft is typically 0.5 ~ 5 × 10⁻⁴ kg·m², which is of the same order as the rotor inertia for a small motor. If Jgb is omitted when matching a small-inertia motor, the inertia ratio is underestimated by 20% ~ 50%. At high ratios (i ≥ 50) the gearbox's own inertia accounts for an even larger share and must be looked up in the catalogue and included.
For a homogeneous disc about its central axis. For a hollow turntable (including fixtures), accumulate segment by segment using ½ · (m · r_out² − m_in · r_in²); for an eccentric load add m · e² (parallel axis theorem).
θ is the rotation angle (rad) and t the indexing time. For a trapezoidal profile use α = θ / (ta · (t − ta)), where the acceleration time ta is normally one quarter to one third of the total time.
This is the quick estimate for the lower bound of the ratio; for the exact calculation add the gearbox's own inertia Jgb and verify ratio by ratio.
This is the upper bound of the ratio. There must be a non-empty interval between the lower and upper bounds, otherwise the motor specification or the motion requirement has to be adjusted — this is the most typical sign of a failed match.
η is the gearbox efficiency: 0.95 ~ 0.97 for a single-stage planetary, 0.92 ~ 0.95 for two stages; 0.4 ~ 0.75 for a worm gear, and lower when self-locking.
Peak torque = acceleration + friction + process resistance, all referred to the motor shaft and then added, and compared with the motor maximum torque.
Weighted by the square and by the share of time of each duty. In an indexing turntable takt of "index + dwell", the torque during the dwell is very small, which is favourable for Trms; for continuous rotating conveyors the calculation must be based on the real load spectrum.
The gearbox backlash shows up directly at the output and is independent of the gear ratio (backlash is itself an output-side figure). A precision turntable should select ≤ 3 arcmin, while general transmission is fine with 5 ~ 8 arcmin — and the price difference is more than double.
| Size | Rated output torque T2N | Backlash (standard / precision) | Typical ratios | Input inertia Jgb |
|---|---|---|---|---|
| φ60 | 20 N·m | ≤ 8′ / ≤ 3′ | 15 ~ 100 | 0.4 ~ 0.8 × 10⁻⁴ kg·m² |
| φ70 | 30 N·m | ≤ 8′ / ≤ 3′ | 15 ~ 100 | 0.7 ~ 1.2 × 10⁻⁴ kg·m² |
| φ90 | 60 N·m | ≤ 8′ / ≤ 3′ | 15 ~ 100 | 1.2 ~ 1.8 × 10⁻⁴ kg·m² |
| φ115 | 120 N·m | ≤ 8′ / ≤ 3′ | 15 ~ 100 | 2.5 ~ 4.0 × 10⁻⁴ kg·m² |
| Application | Recommended inertia ratio | Explanation |
|---|---|---|
| High precision turntables, cam followers | ≤ 3 | Both the backlash and the inertia ratio are tightly controlled |
| General indexing, robot joints | ≤ 5 | The best value-for-money range |
| Conventional conveying, lifting | ≤ 10 | Reduce the gain as appropriate |
| Low speed, high torque (mixing, hoisting) | ≤ 20 | Low response requirements; torque and heat are the focus |
| Type | Efficiency | Notes |
|---|---|---|
| Planetary, single stage | 0.95 ~ 0.97 | First choice, small inertia and small backlash |
| Planetary, two stages | 0.92 ~ 0.95 | Ratios 15 ~ 100 |
| Worm gear | 0.4 ~ 0.75 | Compact at high ratios, high heat generation |
| Cycloidal | 0.9 ~ 0.95 | Heavy load, impact resistant |
| Harmonic drive | 0.75 ~ 0.85 | Zero backlash, small torque duties |
| Verification item | Recommended criterion | Actual in this example |
|---|---|---|
| Gear ratio interval | √(JL/(k·JM)) ≤ i ≤ 0.8n_max/n_load, and the interval must be non-empty | [79, 96], take 90 ✓ |
| Inertia ratio | (JL/i² + Jgb)/JM ≤ 10 | 9.5 ✓ |
| Peak torque | Tp ≤ 0.8 × motor maximum torque | 0.45 / 7.16 = 6% ✓ |
| Continuous torque | Trms ≤ 0.8 × motor rated torque | 0.24 / 2.39 = 10% ✓ |
| Gearbox continuous torque | ≤ 0.7 × T2N | 20.5 / 42 ✓ |
| Backlash | Back-calculated from the positioning accuracy | 0.26 mm ≤ 0.3 mm ✓ |
| Wrong practice | Consequence | Correct practice |
|---|---|---|
| Fixing the gear ratio only by "dividing the speed down" | The inertia ratio is exceeded, the servo gain cannot be tuned and the positioning oscillates and overshoots | Calculate the inertia matching lower bound first, then the speed upper bound, and let the two constraints squeeze out the interval |
| Forcing a choice when the inertia lower bound and the speed upper bound conflict | Either the acceleration fails or the machine runs in the field-weakening region at high speed | Relax the motion time, change to a larger-inertia motor or step up the motor size, and recalculate the interval |
| Omitting the gearbox's own inertia Jgb | With a small-inertia motor the inertia ratio is underestimated by 20% ~ 50% and the machine oscillates on site | Look it up in the catalogue and include Jgb together with JL/i² and JM |
| Checking only whether the gearbox rated torque is adequate | The backlash is over the limit so positioning cannot be achieved; a cantilevered output shaft breaks from the radial load | Check the backlash, the radial and axial load and the efficiency alongside the torque |
| Treating the efficiency as 1 | The referred torque is underestimated by 5% ~ 10%; in worm gear applications by nearly half | Take 0.92 ~ 0.95 for a two-stage planetary, and the actual value for a worm gear |
| Using the gearbox peak torque as the continuous torque | Pitting of the tooth flanks and early failure, with the life collapsing | Continuous torque ≤ 0.7 × T2N, and check the permissible duration of the peak against the catalogue |
| Not distinguishing the triangular from the trapezoidal profile and estimating the angular acceleration by feel | The acceleration torque error can exceed 30% | Triangular α = 4θ/t², trapezoidal calculated from the actual acceleration phase |