Reaming allowance left after drilling and rough-to-finish reaming allowance for hole machining, used to plan hole-machining process routes.
| Hole dia. d (mm) | Drill dia. d_drill (mm) | Reaming allowance (mm) | Rough to finish reaming (mm) | Remarks |
|---|---|---|---|---|
| 2 | 1.9 | 0.1 | 0.05 | Reaming to IT7-IT9; HSS reamer |
| 3 | 2.88 | 0.12 | 0.06 | Reaming to IT7-IT9; HSS reamer |
| 4 | 3.88 | 0.12 | 0.06 | Reaming to IT7-IT9; HSS reamer |
| 5 | 4.88 | 0.12 | 0.06 | Reaming to IT7-IT9; HSS reamer |
| 6 | 5.85 | 0.15 | 0.07 | Reaming to IT7-IT9; HSS reamer |
| 8 | 7.85 | 0.15 | 0.07 | Reaming to IT7-IT9; HSS reamer |
| 10 | 9.8 | 0.2 | 0.1 | Reaming to IT7-IT9; HSS reamer |
| 12 | 11.8 | 0.2 | 0.1 | Reaming to IT7-IT9; HSS reamer |
| 15 | 14.8 | 0.2 | 0.1 | Reaming to IT7-IT9; HSS reamer |
| 18 | 17.75 | 0.25 | 0.12 | Reaming to IT7-IT9; HSS reamer |
| 20 | 19.75 | 0.25 | 0.12 | Reaming to IT7-IT9; HSS reamer |
| 25 | 24.75 | 0.25 | 0.12 | Reaming to IT7-IT9; HSS reamer |
| 30 | 29.65 | 0.35 | 0.17 | Reaming to IT7-IT9; HSS reamer |
| 35 | 34.65 | 0.35 | 0.17 | Reaming to IT7-IT9; HSS reamer |
| 40 | 39.65 | 0.35 | 0.17 | Reaming to IT7-IT9; HSS reamer |
| 45 | 44.65 | 0.35 | 0.17 | Reaming to IT7-IT9; HSS reamer |
| 50 | 49.55 | 0.45 | 0.23 | Reaming to IT7-IT9; HSS reamer |
| 60 | 59.55 | 0.45 | 0.23 | Reaming to IT7-IT9; HSS reamer |
| 70 | 69.55 | 0.45 | 0.23 | Reaming to IT7-IT9; HSS reamer |
| 80 | 79.4 | 0.6 | 0.3 | Reaming to IT7-IT9; HSS reamer |
| 90 | 89.4 | 0.6 | 0.3 | Reaming to IT7-IT9; HSS reamer |
| 100 | 99.4 | 0.6 | 0.3 | Reaming to IT7-IT9; HSS reamer |
| 110 | 109.4 | 0.6 | 0.3 | Reaming to IT7-IT9; HSS reamer |
| 120 | 119.4 | 0.6 | 0.3 | Reaming to IT7-IT9; HSS reamer |
| 130 | 129.4 | 0.6 | 0.3 | Reaming to IT7-IT9; HSS reamer |
Too small a reaming allowance cannot correct pre-hole errors, too large easily causes heat and reamer wear; take upper limit for cast iron and lower limit for non-ferrous metals. Pre-hole roughness before finish reaming should be <= Ra3.2.
See all quick calculators on the knowledge base home page.
Data compiled from publicly available GB/T standard tables for design reference only. For final design and acceptance, always consult the original standard and the latest supplier catalog.