Common wire rope constructions (6×19/6×37), diameter series and safety-factor requirements for sling selection.
| Construction | Feature | Typical application |
|---|---|---|
| 6×19+FC/IWR | Thick wires, wear-resistant, fairly stiff, poor flexibility | Towing, tensioning, guy wires |
| 6×37+FC/IWR | Fine wires, flexible, good fatigue resistance | Lifting slings (most common) |
| 6×36WS+IWRC | Line contact, high load capacity, long life | Critical lifts, elevators |
| Multi-strand non-rotating (18×7, etc.) | Does not rotate under load | Single-rope free suspension lifting |
Check the breaking force against the standard rated value (1770/1960 MPa grade); rough estimate ≈ 0.3~0.35 × d² kN (d=mm, fiber core 1770 grade, reference only). Safety factor: general slings ≥5~7 (mandatory per lifting code); scrap criteria: number of broken wires in one lay length exceeds limit / diameter wear ≥7% / birdcaging / broken strand — scrap directly.
See all quick calculators on the knowledge base home page.
Data compiled from publicly available GB/T standard tables for design reference only. For final design and acceptance, always consult the original standard and the latest supplier catalog.