Worm reducers are notorious for low efficiency and high heat generation. At the same power the heat generation can be 2~3 times that of a gear reducer. Once the oil temperature goes above 85°C the oil film breaks down, the seals fail and the worm wheel flanks scuff, and the unit is scrap within three months. Many people have learned this the hard way — the calculation on the drawing looks fine, yet three months after installation it starts leaking oil. Below we work through the cooling calculation for a typical worm reducer and then show how to choose between a fan and water cooling.
A worm reducer with center distance a = 160 mm, input power 7.5 kW, worm speed n₁ = 1440 r/min, ratio i = 20 and overall efficiency η = 0.75. The housing is cast iron with outline dimensions 700 long × 400 wide × 420 high mm. The ambient temperature is 35°C (a workshop in summer) and the permissible oil temperature is 85°C. Verify whether the cooling is sufficient and, if not, select a cooling scheme.
All the power lost in the worm reducer is converted into heat:
Of the 7.5 kW input, 25% is lost, so 1.875 kW becomes frictional heat and this heat has to be dissipated through the housing. By comparison, a gear reducer of the same power typically generates only 0.4~0.6 kW.
Outer surface of the housing (excluding the base and the shaft extensions): length L = 0.7 m, width W = 0.4 m, height H = 0.42 m.
Take a reduction factor k_A = 0.55 for the effective cooling area (allowing for the base sitting on the floor and the shielding between the ribs on the sides):
A worm reducer usually has a larger housing than a gear reducer of the same size, but because the layout of the cooling fins constrains it, the effective area is reduced more.
Take the natural cooling heat transfer coefficient α = 12 W/(m²·°C) (cast iron housing, indoors with no air flow):
P_v = 1.875 kW >> Q_cool = 0.492 kW, so the cooling is seriously insufficient!
Estimated steady-state oil temperature:
The oil temperature far exceeds the permissible 85°C, so forced cooling measures must be adopted.
Fit an axial fan at the end of the worm shaft; take the forced air cooling heat transfer coefficient α_f = 28 W/(m²·°C):
P_v = 1.875 kW > Q_cool_f = 1.148 kW, so this is still not enough!
Steady-state oil temperature: t_o = 35 + 1875/(28 × 0.82) = 35 + 81.6 ≈ 116.6°C, over the limit.
Add cooling fins to the housing to raise the effective cooling area from 0.82 m² to 1.50 m²:
Q_cool_f2 = 2.10 kW ≥ P_v = 1.875 kW, so the requirement is satisfied!
Steady-state oil temperature: t_o = 35 + 1875/(28 × 1.50) = 35 + 44.6 ≈ 79.6°C ✅ below 85°C
Selected scheme: adding cooling fins plus a shaft-mounted fan meets the cooling requirement, at low cost and with simple implementation.
If there is no room for fins, consider a water cooling coil in the oil sump, with α_w = 200 W/(m²·°C) (based on the coil area) and coil area A_w = 0.15 m²:
Adding the natural cooling of 0.492 kW gives a total of 1.992 kW > 1.875 kW, so the requirement is satisfied.
However, a cooling water circulation system is then required, which suits situations where cooling water is available. Note that the inlet water temperature must be ≤ 25°C, otherwise the effect is degraded.
This case recommends Scheme 2: fit a shaft-mounted fan and add cooling fins to the housing to raise the effective area to 1.5 m², giving a steady-state oil temperature of about 80°C, which is safe and reliable. If cooling water is available on site, the water cooling coil scheme is also an option. The two schemes differ in cost and applicable conditions, so choose according to the actual duty.
A worm drive has a high sliding velocity and severe flank friction, and the overall efficiency is typically only 50%~85%. With the same 10 kW input, a worm reducer may lose 2~5 kW of heat while a gear reducer loses only 0.5~1 kW. Cooling design for a worm reducer therefore has almost the same priority as the strength calculation.
| Cooling method | Heat transfer coefficient (W/m²·°C) | Applicable power range | Cost | Implementation difficulty |
|---|---|---|---|---|
| Natural cooling | 8~15 | P_in ≤ 2 kW | Low | None |
| Shaft-mounted fan (forced air cooling) | 20~35 | 2~15 kW | Low | Simple |
| Water cooling coil / jacket | 150~300 | ≥10 kW or high ambient temperature | Medium | Circulating water required |
Engineering experience: with no cooling measures at all, the permissible input power of a worm reducer is usually only 40%~60% of the rated load capacity. In other words, a worm reducer selected on strength can only actually deliver half its rated power — the other half is limited by the cooling.
P_v — heat generation power (kW); P_in — input power (kW); η — overall gearbox efficiency
L, W, H — length, width and height of the housing outline (m). For a worm reducer, take all outer surfaces except the underside of the base.
k_A — effective cooling factor: 0.5~0.6 for a housing without fins, and 0.7~0.85 for a finned housing (after converting to the developed fin area).
α — heat transfer coefficient (W/m²·°C); t_o — oil temperature (°C); t_a — ambient temperature (°C)
[t] — permissible oil temperature: 80~85°C for mineral oil and 90~95°C for synthetic oil; above 100°C forced cooling is mandatory.
α_0 — natural cooling coefficient (W/m²·°C); v — air velocity across the housing surface (m/s). At v≥2 m/s, α_f can reach 25~35 W/(m²·°C).
| Center distance a (mm) | Rough housing area (m²) | Permissible input with natural cooling (kW) | Permissible input with fan cooling (kW) |
|---|---|---|---|
| 80 | 0.18~0.28 | 0.3~0.6 | 0.8~1.5 |
| 100 | 0.28~0.45 | 0.6~1.2 | 1.5~3.0 |
| 125 | 0.45~0.65 | 1.2~2.0 | 3.0~5.0 |
| 160 | 0.65~0.95 | 2.0~3.5 | 5.0~8.0 |
| 200 | 0.95~1.35 | 3.5~6.0 | 8.0~12 |
| 250 | 1.35~1.90 | 6.0~10 | 12~18 |
| Center distance a (mm) | Recommended air volume (m³/h) | Fan diameter (mm) | Mounting position |
|---|---|---|---|
| 80~100 | 200~400 | 120~160 | Worm shaft extension end |
| 125~160 | 400~800 | 160~200 | Worm shaft extension end |
| 200~250 | 800~1500 | 200~300 | Worm shaft extension end or a separate fan unit |
| Parameter | Recommended value | Description |
|---|---|---|
| Coil material | Copper or stainless steel | Good thermal conductivity, resistant to oil corrosion |
| Tube diameter | 10~16 mm | The bore should not be too small, to avoid scaling and blockage |
| Layout position | Lower part of the oil sump | Avoid the region churned by the rotating worm wheel |
| Inlet water temperature | ≤ 25°C | Outlet water temperature ≤ 40°C |
| Water flow velocity | 1.0~2.0 m/s | Too slow harms the heat transfer, too fast causes a large pressure drop |
| No. | Common mistake | Consequence | Correct practice |
|---|---|---|---|
| 1 | Selecting on strength alone and skipping the cooling check | Oil temperature of 80~150°C, with scuffing and oil leakage within three months | A worm reducer always requires both a strength and a thermal balance check, and neither can be omitted |
| 2 | Using the outer envelope of the housing directly as the cooling area | The cooling area is overstated by more than 50% and the check loses accuracy | It must be multiplied by the reduction factor k_A = 0.5~0.7, and a finned housing is converted from the developed fin area |
| 3 | Taking the heat transfer coefficient α at its upper limit | The calculated oil temperature looks fine but actually rises by more than ten degrees | Take 10~12 without a fan and 20~28 with a fan, and design conservatively |
| 4 | Taking the ambient temperature as the 20°C room temperature | At 40°C in summer the oil temperature immediately exceeds the limit | Verify against the worst case — the highest summer ambient temperature |
| 5 | Mounting the fan on the low-speed shaft end | Insufficient air volume and a negligible cooling effect | The fan must be mounted on the worm shaft (high-speed shaft) end with a speed ≥1000 r/min |
| 6 | The water cooling coil has too high an inlet water temperature | The oil near the coil is cooled well but the overall oil temperature does not come down | Inlet water temperature ≤ 25°C with sufficient flow, and outlet water temperature ≤ 40°C |