Bore vs working pressure of two-wire braid hydraulic hose (2SN); for hose assembly selection.
| Bore DN | Fitting (approx.) | Working pressure (MPa) approx. | Min. bend radius (mm) approx. |
|---|---|---|---|
| DN6 | G1/4 | 40 | 100 |
| DN8 | G3/8 | 35 | 115 |
| DN10 | G1/2 | 30 | 140 |
| DN12 | G1/2 | 27 | 170 |
| DN16 | G3/4 | 25 | 210 |
| DN19 | G3/4 | 22 | 250 |
| DN25 | G1 | 17 | 340 |
| DN32 | G1 1/4 | 15 | 430 |
Approximate; samples vary by maker – derate 25% per catalogue (pulse/temperature margin). Single-wire 1SN is about 55-65% of the table. Never fold hose; insufficient bend radius causes early burst.
See all quick calculators on the knowledge base home page.
Data compiled from publicly available GB/T standard tables for design reference only. For final design and acceptance, always consult the original standard and the latest supplier catalog.