Once the V-belt type, the pulley diameters and the center distance have been fixed by the selection step, the most critical remaining task is to work out exactly how many belts are required. Too few belts slip and burn out; too many increase the shaft load and the bearing load, make installation difficult and waste cost. The following works through one case first, and then explains the formulas.
Design power Pd = 18 kW, type B V-belt, small pulley reference diameter dd1 = 140 mm, large pulley reference diameter dd2 = 315 mm, belt speed v = 10.63 m/s, center distance a = 636 mm, small pulley wrap angle α1 = 164.2°.
Refer to the type B single-belt rated power table (GB/T 13575.1): at dd1 = 140 mm and n1 = 1450 r/min:
P1 = 3.65 kW
The transmission ratio is i = 2.25 (not a 1:1 drive). The large pulley diameter is greater than the small one, so the bending stress of the belt is reduced and the permissible transmitted power increases.
Refer to the type B rated power increment table; at i ≈ 2.25 and n1 = 1450 r/min:
ΔP1 = 0.42 kW
The small pulley wrap angle is α1 = 164.2°. Look it up in the wrap angle coefficient table or use the formula:
Check by interpolation: α = 160° → Kα = 0.95, α = 170° → Kα = 0.98; linear interpolation at 164.2° gives Kα ≈ 0.965. Take the conservative value Kα = 0.955.
Reference belt length Ld = 2000 mm; refer to the type B belt length coefficient table:
At Ld = 2000 mm, KL = 1.02
Round up and take z = 5 belts
The recommended range for type B V-belts is 2~8 belts, and 6 belts is the common maximum. z = 5 is within a reasonable range.
If the number of belts exceeds 8, a larger type (such as type C) or a narrow V-belt should be considered instead.
| Parameter | Value |
|---|---|
| V-belt type | Type B |
| Rated power per belt P1 | 3.65 kW |
| Rated power increment ΔP1 | 0.42 kW |
| Wrap angle coefficient Kα | 0.955 |
| Belt length coefficient KL | 1.02 |
| Calculated number of belts | 4.54 |
| Actual number of belts z | 5 belts |
| Actual loading rate per belt | 4.54/5 = 90.8% |
The cross-sectional size of a single V-belt is limited, and the transmitted power is constrained by the cross-sectional area and the material strength. When the design power exceeds the rated power of a single belt, several belts must operate in parallel so that the load is shared among them.
| Factor | Direction of influence | Remarks |
|---|---|---|
| Design power Pd | More belts required | The greater the load, the more belts are needed to share it |
| Rated power per belt P1 | Fewer belts required | A larger belt type has a higher load capacity per belt |
| Wrap angle coefficient Kα | The smaller the wrap angle, the more belts | An insufficient wrap angle reduces friction, so more belts are needed to compensate |
| Belt length coefficient KL | Short belts need more, long belts need fewer | Short belts bend more frequently, and their life is reduced |
| Transmission ratio | A large ratio is favourable | The large pulley bends the belt less, which is compensated by the ΔP1 increment |
| Type | Recommended number of belts | Maximum number | Remarks |
|---|---|---|---|
| Y | 1~3 | 4 | Low power applications |
| Z | 1~4 | 6 | Light-duty drives |
| A | 2~6 | 8 | Small and medium power |
| B | 2~6 | 8 | Most common for medium power |
| C | 2~8 | 10 | Medium to high power |
| D | 3~10 | 12 | High power |
| E | 3~12 | 15 | Very high power |
| Symbol | Meaning | Unit |
|---|---|---|
| z | Number of V-belts (rounded to an integer) | belts |
| Pd | Design power | kW |
| P1 | Rated power of a single V-belt (from a table) | kW |
| ΔP1 | Rated power increment (when the ratio ≠ 1) | kW |
| Kα | Wrap angle coefficient | — |
| KL | Belt length coefficient | — |
It can also be looked up directly in a table:
| Wrap angle α1 | 90° | 100° | 110° | 120° | 130° | 140° | 150° | 160° | 170° | 180° |
|---|---|---|---|---|---|---|---|---|---|---|
| Kα | 0.68 | 0.73 | 0.78 | 0.82 | 0.86 | 0.89 | 0.92 | 0.95 | 0.98 | 1.00 |
Taking type B as an example (look up the corresponding table for other types):
| Reference length Ld (mm) | 670 | 750 | 900 | 1000 | 1120 | 1250 | 1400 | 1600 | 1800 | 2000 | 2240 | 2500 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| KL | 0.80 | 0.83 | 0.86 | 0.88 | 0.90 | 0.93 | 0.96 | 0.98 | 1.01 | 1.02 | 1.05 | 1.07 |
| Symbol | Meaning | Remarks |
|---|---|---|
| Kb | Bending influence coefficient | Related to the belt type; look up in a table |
| n1 | Small pulley speed | r/min |
| Ki | Transmission ratio coefficient | Related to the transmission ratio; look up in a table |
In actual design, ΔP1 is normally obtained directly from the standard tables, with no need for manual calculation.
| n1 (r/min) | dd1=125mm | dd1=140mm | dd1=160mm | dd1=180mm | dd1=200mm |
|---|---|---|---|---|---|
| 730 | 2.02 | 2.43 | 2.94 | 3.42 | 3.86 |
| 980 | 2.57 | 3.11 | 3.78 | 4.41 | 5.01 |
| 1200 | 3.00 | 3.63 | 4.43 | 5.17 | 5.87 |
| 1450 | 3.35 | 3.65 | 4.85 | 5.67 | 6.43 |
| 1600 | 3.50 | 4.22 | 5.15 | 6.02 | 6.83 |
Note: the above are the base rated powers at i=1; for the complete data see GB/T 13575.1.
| Type | Y | Z | A | B | C | D | E |
|---|---|---|---|---|---|---|---|
| Kb×10³ | 0.05 | 0.13 | 0.23 | 0.44 | 0.77 | 1.56 | 2.56 |
| Transmission ratio i | 1.00~1.01 | 1.02~1.04 | 1.05~1.08 | 1.09~1.12 | 1.13~1.18 | 1.19~1.24 | 1.25~1.34 | 1.35~1.51 | 1.52~1.99 | ≥2.00 |
|---|---|---|---|---|---|---|---|---|---|---|
| Ki | 1.000 | 1.013 | 1.027 | 1.041 | 1.054 | 1.067 | 1.080 | 1.094 | 1.107 | 1.120 |
| # | Common mistake | Consequence | Correct practice |
|---|---|---|---|
| 1 | Ignoring the wrap angle coefficient Kα correction | Too few belts, the belt slips where the wrap angle is insufficient | The effective power of each belt must be multiplied by Kα; the smaller the wrap angle, the more significant the correction |
| 2 | Ignoring the ΔP1 increment brought about by the transmission ratio | Too many belts, causing waste and excessive shaft load | When the ratio > 1 the bending stress of the large pulley decreases, so the ΔP1 increment must be included |
| 3 | Not rounding the calculated number of belts, or rounding down | Insufficient capacity, the belt is overloaded and slips | The calculated value of z must be rounded up to an integer; rounding down is not permitted |
| 4 | Continuing to add belts beyond 8 | Severely uneven load among the belts, and the length difference makes some belts idle | Above 8 belts the type should be upgraded or a narrow V-belt (SPB, SPC, etc.) adopted |
| 5 | Ignoring the influence of the belt length coefficient KL | Too few belts for a short belt, high bending frequency and insufficient life | Short belts bend more often and KL < 1 must be applied as a reduction; for long belts KL > 1 allows slightly fewer belts |
— Baisi Technical Handbook · V-belt number of belts calculation —