When a hydraulic cylinder runs at high speed to the end of its stroke, the piston slams straight into the cylinder head — at best the seals fail, at worst the head deforms and the piston fractures. The purpose of the cushioning device is to plug the oil outlet with a cushion plunger at the end of the stroke, so that the restricted outflow generates a back pressure that “squeezes” the kinetic energy into hydraulic energy and brings the piston to a gradual stop. Below we work through the whole cushioning back pressure calculation with one high-speed cylinder.
Bore D = 100 mm, piston rod diameter d = 50 mm, working pressure p = 16 MPa.
Total mass of the moving parts m = 2000 kg (including the load), speed before impact v = 0.5 m/s, cushioning stroke s_b = 30 mm, cushion plunger diameter d_b = 40 mm.
Find: the cushioning back pressure p_b and verify whether it exceeds the test pressure.
The effective pressurised area of the cushion plunger as it enters the cushioning chamber determines the magnitude of the cushioning resistance.
Velocity affects kinetic energy quadratically — double the speed and the kinetic energy quadruples. This is the fundamental challenge of cushioning at high speed.
Conservation of energy: back pressure × cushioning volume = kinetic energy. Unit conversion: m[kg]×v²[m²/s²] / (A_b[m²]×s_b[m]) = Pa.
The cushioning back pressure must stay below the test pressure (normally 1.5 times the working pressure), otherwise the cushioning chamber is at risk of bursting.
The work done by the back pressure (hydraulic energy) equals the kinetic energy of the moving parts, so the energy is fully absorbed and the piston stops safely.
If the impact speed rises to v = 1.0 m/s (double):
Kinetic energy E_k = 0.5×2000×1 = 1000 J (four times)
Back pressure p_b = 2000×1 / (2×1257×0.03) ≈ 26.5 MPa > 24 MPa ✗ Cushioning over-pressure!
Measure 1: lengthen the cushioning stroke to 50 mm → p_b = 15.9 MPa ✓
Measure 2: increase the cushion plunger diameter to 50 mm → p_b = 17.0 MPa ✓
Measure 3: reduce the impact speed (fit a throttle valve)
| Type | Principle | Characteristics | Applicable |
|---|---|---|---|
| Annular orifice cushioning | The cushion plunger forms an annular gap with the cylinder head that throttles the flow | Simple structure, constant cushioning back pressure | Medium and low speeds, small to medium loads |
| Throttle valve cushioning | An external throttle valve varies the throttling area | The cushioning curve is adjustable | Medium speeds, medium loads |
| Variable orifice cushioning | The cushion plunger is tapered so the gap changes progressively | Smooth cushioning, small shock | High speed, heavy loads |
| Accumulator cushioning | The discharged oil is stored in an accumulator | Absorbs a large amount of energy, gentle cushioning | Large heavy-duty hydraulic cylinders |
| Piston speed v | Recommended cushioning stroke s_b | Cushion plunger to piston area ratio A_b/A |
|---|---|---|
| ≤ 0.1 m/s | No cushioning needed | — |
| 0.1 ~ 0.5 m/s | 20~40 mm | 0.2~0.3 |
| 0.5 ~ 1.0 m/s | 40~80 mm | 0.3~0.5 |
| > 1.0 m/s | 80~150 mm | 0.5~0.7 |
1. Cushion plunger area:
2. Kinetic energy of the moving parts:
3. Cushioning back pressure (energy conservation method):
4. Test pressure:
5. Verification condition:
6. Energy balance verification:
| Symbol | Meaning | Unit | Value notes |
|---|---|---|---|
| m | Total mass of the moving parts | kg | Including the load, the piston and the piston rod |
| v | Speed before impact | m/s | Take the maximum speed, not the average |
| A_b | Cushion plunger area | mm² | Set by the structural design |
| s_b | Cushioning stroke | mm | Length of the cushion plunger |
| p_w | Working pressure | MPa | 1 MPa = 1 N/mm² |
| p_test | Test pressure | MPa | Normally 1.5×p_w |
| Cushioning back pressure range | Assessment | Measures |
|---|---|---|
| p_b < 0.5×p_test | The cushioning force is too small and the piston still strikes hard | Reduce the cushioning stroke / the plunger area |
| 0.5×p_test ~ p_test | The cushioning force is reasonable ✓ | — |
| p_b > p_test | Over-pressure in the cushioning chamber is dangerous | Lengthen the stroke / enlarge the plunger / add throttling |
| # | Common error | Consequence | Correct practice |
|---|---|---|---|
| 1 | Counting only the piston weight in m | The kinetic energy is understated and the cushioning force is insufficient | Include the piston, the piston rod, the load and the fixture |
| 2 | Taking the average speed | The kinetic energy is understated and the cushioning fails | Take the maximum speed before impact |
| 3 | Taking the cushion plunger area too small | The back pressure is falsely low and appears acceptable | Use the actual area from the structural design |
| 4 | Not checking against the test pressure | The cushioning chamber bursts from over-pressure | p_b ≤ 1.5×p_w |
| 5 | Throttle valve cushioning with no return-line damping | The cushioning fails and the piston still strikes the cylinder head | Fit a back pressure valve at the throttle valve outlet |