An accumulator is the “power bank” of a hydraulic system — it stores energy while the pump is busy and releases it while the pump rests, and it also absorbs shocks and pulsations. If the capacity is too small the supply is insufficient and the system stalls; too large and it is expensive and bulky. The key to selection is to identify the duty and then calculate the volume for an isothermal or an adiabatic process. Below we work both methods through one energy storage example.
Maximum system working pressure p₁ = 12 MPa, minimum working pressure p₂ = 8 MPa, and the accumulator is required to deliver ΔV = 2 L of oil.
A gas-charged bladder accumulator is used with a precharge pressure p₀ = 0.9 × p₂ = 7.2 MPa. Find the total accumulator volume and select a type.
The accumulator follows the gas law p₀V₀n = constant:
The isothermal process suits slow duties such as holding pressure and compensating leakage, giving a calculated volume of 6.7 L.
The adiabatic process suits transient duties such as rapid oil delivery and shock absorption, giving a calculated volume of 8.6 L, which is larger than the isothermal value. Select on the larger adiabatic value.
Allowing a margin on the adiabatic result of 8.6 L, select the standard 10 L bladder accumulator(such as NXQ-10).
Rated pressure check: with a system pressure of 12 MPa, choose a model rated at 16 MPa; the safety factor = 16/12 ≈ 1.33 ≥ 1.3 ✓
| Type | Working principle | Characteristics | Applicable |
|---|---|---|---|
| Bladder type | Nitrogen in the bladder, the oil pressurises the bladder | Fast response, low leakage rate, by far the most widely used | Energy storage, pressure holding, shock absorption |
| Diaphragm type | A rubber diaphragm separates the gas from the oil | Small volume, light weight, low precharge pressure | Small capacities, pulsation damping |
| Piston type | A free piston separates the gas from the oil | Large capacity and high pressure rating, but with friction | Energy storage at high flow rates |
| Duty | Function | Typical application |
|---|---|---|
| Energy storage (auxiliary power source) | The pump can be one size smaller and supplies during peak demand | Injection moulding machines and presses working intermittently |
| Pressure holding | Compensates leakage so the pump can be switched off | Fixture pressure holding, brake pressure holding |
| Shock absorption | Eliminates water hammer and protects valves and piping | Rapid directional valve closure, hydraulic shock |
| Pulsation damping | Smooths pressure fluctuations and reduces noise | Plunger pump outlets, precision servo systems |
1. Gas law (generalised Boyle’s law):
2. Isothermal volume (n = 1, pressure holding / leakage compensation):
3. Adiabatic volume (n = 1.4, rapid oil delivery / shock absorption):
4. Effective oil delivery:
| Symbol | Meaning | Unit | Value notes |
|---|---|---|---|
| p₀ | Precharge (gas fill) pressure | MPa | Bladder type (0.8~0.9)p₂, diaphragm type (0.25~0.5)p₂ |
| p₁ | Maximum working pressure | MPa | Pressure at the end of energy storage |
| p₂ | Minimum working pressure | MPa | Pressure at the end of oil delivery, p₂ ≥ the load demand |
| ΔV | Effective oil delivery | L | Determined by the requirement of the actuator |
| n | Polytropic exponent | — | Adiabatic 1.4, isothermal 1 |
| Accumulator type | Precharge pressure p₀ | Notes |
|---|---|---|
| Bladder type (energy storage) | (0.8~0.9) × p₂ | p₂ is the minimum working pressure |
| Bladder type (shock absorption) | (0.6~0.65) × the working pressure | The lower the precharge, the better the absorption |
| Diaphragm type | (0.25~0.5) × p₂ | Influenced by the diaphragm stiffness |
| Piston type | (0.8~0.9) × p₂ | The same as the bladder type |
| # | Common error | Consequence | Correct practice |
|---|---|---|---|
| 1 | Confusing the isothermal and adiabatic processes | Calculating a pressure-holding duty as adiabatic gives an oversized volume and wasted cost | Use adiabatic n=1.4 for fast delivery and shock, isothermal n=1 for slow pressure holding |
| 2 | Wrong precharge pressure | Insufficient oil delivery capability, or the bladder is crushed solid | Bladder type p₀=(0.8~0.9)p₂, diaphragm type (0.25~0.5)p₂ |
| 3 | Not allowing a margin on the volume | The nitrogen contracts in winter and the oil delivery falls short | Take the larger value and allow a 10~20% margin |
| 4 | Using oxygen for the precharge | Oil and gas mix, with a risk of explosion | Use nitrogen only, and take the precharge from the datasheet |
| 5 | Using the energy storage formula for shock absorption | The capacity is too small and the shock absorption is insufficient | Use the dedicated empirical formula for shock duty |