Interference Fit Assembly Calculator (heating temp / press force)

Enter the joining diameter and interference to estimate the heating temperature for thermal mounting and the press-fit force. Essential for assembly process cards and field assembly.

Calculation basis

Heating Δt=(δ+g)/(α·d), steel α≈11×10⁻⁶/°C, g=assembly clearance 0.01~0.02 mm;Upper limit 250 °C (avoid annealing).Press force F=π·d·L·p·μ, p=δ/[d(C₁/E₁+C₂/E₂)] (thick-wall Lamé formula, E=206 GPa, ν=0.3).Assembly practice: see the interference-fit assembly table (tb-82).Press force is an estimate — keep 30% capacity margin on the press.

Result:Enter parameters