MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
Knowledge Base › General Engineering & Case Studies › How to Calculate the Capacity
HomeModels
Table of contents

General Engineering & Case Studies (60 articles)

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

🛠️ Baisi Technical Handbook · Intelligent selection and calculation for 500+ standard parts
Covers the full range of pneumatic / motor / power transmission / reducer / coupling / bearing / hydraulic / pneumatic / thread / worm / spring parts
Avoid 95% of design errors, improve design efficiency by 80%
Master 10 years of senior engineer experience in 3 months
Download: https://pan.baidu.com/s/1bquayZpfas6oYBbG0gp3Gw?pwd=2giv

📖 Next issue preview: Shear Bolt Group Calculation

How to Calculate the Capacity of High-Strength Bolt Friction-Type Joints? Worked Example in 3 Steps

The joints of steel structures, bridges and towers mostly rely on high-strength bolt friction-type connections to carry shear. Load transfer does not come from bearing on the hole wall but from friction between plates clamped by the preload. If a single bolt is calculated wrongly the joint can slip, or even lose overall stability. Below we work through one steel joint example, then unfold the formulas and parameter tables.

1. Complete Worked Example: Number of High-Strength Bolts for a Steel Joint

Step 1 — Look up the bolt preload P

The joint uses M20 high-strength bolts of class 10.9s. From the preload table, the standard preload of an M20 class 10.9s bolt is:

P = 155 kN

The preload is the “soul” of a friction-type connection — all the clamping force between the plates comes from it. Insufficient tightening torque directly shrinks the friction capacity.

Step 2 — Determine the slip coefficient μ

The friction surface is shot-blasted; from the slip coefficient table:

μ = 0.45 (shot-blasted surface)

The connection is double shear (two cover plates clamping one core plate), so the number of friction surfaces nf = 2.

Step 3 — Calculate the shear capacity of one bolt
Nvb = 0.9 · nf · μ · P = 0.9 × 2 × 0.45 × 155 ≈ 125.6 kN

The 0.9 coefficient is a reduction that accounts for material and loading deviations. One M20 bolt can carry about 125.6 kN of shear by friction.

Step 4 — Find the number of bolts required

The joint carries a design shear force of N = 400 kN:

n = N / Nvb = 400 / 125.6 = 3.19 → take n = 4 bolts

Round up to 4 bolts, which satisfies the calculation and leaves a detailing margin.

Step 5 — Lay out the bolts and verify

The 4 M20 bolts are arranged symmetrically in 2 rows × 2 columns. Total capacity check:

n · Nvb = 4 × 125.6 = 502.4 kN ≥ N = 400 kN ✓

The capacity margin is about 25.5%. Next verify the net section of the plate (plate width b=200mm, thickness t=12mm, hole diameter d0=22mm):

An = (b - d0)·t = (200 - 22) × 12 = 2136 mm²
σ = N / An = 400000 / 2136 ≈ 187 MPa < f = 215 MPa (Q235) ✓

Final selection: 4 M20 (10.9s) high-strength bolts, 2×2 layout, shot-blasted friction surfaces, double shear connection; both the connection capacity and the plate strength are acceptable.

🛠️ Baisi Technical Handbook · Connection and Shaft Calculation Module
The Baisi Technical Handbook integrates this calculation module into the Connection and Shaft Calculation Module. Enter the duty parameters and the selection result is output automatically. Say goodbye to flipping through handbooks, to hand calculations, to rule-of-thumb estimates. —— Baisi Technical Handbook download: https://pan.baidu.com/s/1bquayZpfas6oYBbG0gp3Gw?pwd=2giv

2. Friction-Type vs Bearing-Type: First Distinguish the Two Kinds of High-Strength Bolt Connection

High-strength bolt connections are divided into two types by load-transfer mechanism,and their calculation models are completely different — never mix them up:

By type, high-strength bolts are divided intolarge hexagon head bolts(class 8.8s and 10.9s) andtorque-shear type bolts(class 10.9s only). The torque-shear type controls the preload by twisting off the spline head at the tail, which gives more stable installation quality. The preload of both bolt types is taken from the GB/T 1228 table.

3. Core Calculation Formulas

1. Shear capacity of one bolt (friction type)

Nvb = 0.9 · nf · μ · P

2. Number of bolts required

n = N / Nvb(round up)

3. Net section strength check of the plate

σ = N / An ≤ f, An = (b - n1·d0)·t

4. Reference formula for the preload (standard values are taken directly from the table)

P = 0.9 × 0.9 × 0.9 × fu × Ae / 1.2 ≈ 0.61 · fu · Ae

Parameter notes:

SymbolMeaningUnit
NvbShear capacity of one boltkN
nfNumber of friction surfaces (single shear=1, double shear=2)—
μSlip coefficient of the friction surface—
PPreload of the high-strength boltkN
NDesign shear force of the jointkN
AnNet cross-sectional area of the platemm²
fuTensile strength of the boltMPa
AeEffective cross-sectional area of the boltmm²

4. Guide to Design Parameter Selection

1. High-strength bolt preload P (GB/T 1228)

SizeP for class 8.8s (kN)P for class 10.9s (kN)
M1680100
M20125155
M22150190
M24175225
M27215290
M30250355

2. Slip coefficient μ of the friction surface (GB50017)

Contact surface treatment methodQ235Q355/345
Shot blasting (shot peening)0.450.40
Shot blasting (shot peening) followed by inorganic zinc-rich paint0.350.30
Wire brushing to remove loose rust, or as-rolled surfaces not properly cleaned0.300.30

⚠️ Important:the slip coefficient has the greatest influence on the capacity. With the same 0.9·nf·P, raising μ from 0.30 to 0.45 increases the capacity per bolt by 50%. The friction surfaces must be prepared as the design requires; painting or oiling them on site is strictly forbidden.

3. Detailing requirements for bolt layout (minimum spacing)

ItemMinimumNotes
Bolt hole diameter d0d + 1.5~2.0 mmHole diameters for friction type are slightly larger than for bearing type
End distance (in the load direction)2.0·d0Prevents tearing at the end of the member
Edge distance (perpendicular to the load)1.5·d0Values differ for sheared edges and rolled edges
Row pitch / column pitch3·d0Facilitates wrench operation and uniform load transfer

4. Installation and preloading methods

MethodControl methodCharacteristics
Torque methodFinal tightening torque Tc = K·P·dControlled with a torque wrench; K is the torque coefficient (about 0.11~0.15)
Turn-of-nut methodTurn a specified angle after snugging (for example 90°~120°)Preload is controlled by the plastic turn angle, so the scatter is relatively small
Torque-shear type boltsTwisting off the spline head at the tailStandardized preload, the most reliable in the field

5. Common Errors and How to Avoid Them

#Common errorConsequenceCorrect practice
1Applying the bearing-type formula to a friction-type jointThe capacity per bolt is overestimated by 50%~100% and the joint slipsFor friction type always use Nvb = 0.9·nf·μ·P
2Using the P value of class 10.9s for a class 8.8s boltThe clamping force is insufficient and the friction capacity shrinks drasticallyP must be looked up in the table in one-to-one correspondence with the property class
3Leaving the friction surface rusty, painted or contaminated with oilμ drops from 0.45 to below 0.30 and the capacity falls off a cliffPrepare strictly by the specified method and protect the friction surfaces on site
4Not checking the net section strength of the plateThe bolts never break — the plate is torn firstσ = N/An ≤ f must be verified as well
5Re-tightening a torque-shear bolt with a torque wrench after the head has been twisted offThe preload exceeds the limit and the bolt is destroyed prematurelyTwist off once in a single operation; re-tightening is forbidden

Keep one mnemonic in mind for high-strength bolt friction-type connections:“Look up the preload, set the friction, multiply 0.9 by the three parameters”— look up the preload P in the table, set the slip coefficient μ according to the friction surface treatment, capacity per bolt = 0.9×nf×μ×P, then calculate the number, lay out the bolts and check the plate. The steel joint will not slip for ten years.