Allowable safety-factor ranges for static/dynamic/fatigue conditions; the yardstick for 'is it strong enough'.
| Condition | Safety factor n | Remark |
|---|---|---|
| Static load, ductile (steel) | 1.5~2 | When load & material are reliable |
| Dynamic / impact load | 2~3.5 | Vibrating equipment |
| Brittle material (cast iron) | 3~4 | Large strength scatter |
| Fatigue strength of shafts | 1.5~2.5 | Check by fatigue limit |
| Wire rope / lifting gear | 5-7 (per code) | Differs for manual / powered cranes |
| Bolted joint (dynamic) | 1.5~3 | Check by preload & variable load |
A larger safety factor is not always better – doubling n doubles weight and cost; correctly define the load spectrum then set n by industry code. Lifting equipment follows mandatory GB/T values; this table is a general mechanical-design reference.
See all quick calculators on the knowledge base home page.
Data compiled from publicly available GB/T standard tables for design reference only. For final design and acceptance, always consult the original standard and the latest supplier catalog.