The drawing says one line, "material 45 steel", but to run a verification you need tensile strength, yield strength, fatigue limit, elastic modulus and hardness — and these data are scattered over dozens of tables in the handbook. Get one number wrong and the whole calculation is wasted. Below we run the whole chain, "look up the database → calculate the allowable stress → verify → select the material", for a lifting tie rod.
Duty condition: the tie rod of a lifting device works with a fluctuating tensile load of 50~250 kN, 8 hours a day, with a required life of no less than 1 million cycles; the rod body is initially φ40, with threaded connections at both ends. Determine the material grade and the heat treatment condition.
Fluctuating tension-compression → there are two failure modes: yield on first overload (occurring at the first load application) and fatigue fracture (occurring after a million cycles). So four figures are needed: tensile strength σb, yield strength σs, fully reversed fatigue limit σ-1 and elastic modulus E.
Verification targets: static strength safety factor n_s ≥ 1.5; fatigue safety factor n_f ≥ 1.5.
| Grade / condition | σb (MPa) | σs (MPa) | σ-1 tension-compression (MPa) | E (MPa) | HB |
|---|---|---|---|---|---|
| Q235B normalised | 400 | 235 | 119 | 2.06×10⁵ | ≤156 |
| 45 steel quenched and tempered | 650 | 360 | 190 | 2.06×10⁵ | 217~255 |
| 40Cr quenched and tempered | 980 | 785 | 280 | 2.06×10⁵ | 241~286 |
Three points to note: ① for the same grade with different heat treatment, σs can differ by a factor of 2~3, so the condition must be looked up together with the grade; ② the table gives the tension-compression fatigue limit — the bending fatigue limit is about 1.4 times higher; ③ the E of all three steels is identical, so changing the grade cannot change the stiffness.
[σ] = σs / n_s = 360 / 1.5 = 240 MPa (45 steel, quenched and tempered)
Static loading, accurately calculated load, mature experience → take n_s = 1.5; this lifting device is an important application, so 1.5 is already on the strict side and is not reduced further.
A = π×40²/4 = 1257 mm²
σmax = 250000 / 1257 = 198.9 MPa
n_s = 235 / 198.9 = 1.18 < 1.5 ✗
It does not even pass the static strength check, so Q235B is eliminated outright. This step is crucial — trialling with the cheap material first and only upgrading when it fails saves far more than starting with an expensive grade.
n_s = 360 / 198.9 = 1.81 ≥ 1.5 ✓
σmin = 50000 / 1257 = 39.8 MPa
σm = (198.9 + 39.8)/2 = 119.4 MPa
σa = (198.9 − 39.8)/2 = 79.6 MPa
Static strength passes, but fatigue has not yet been checked. Substituting into the Soderberg equation:
σa/σ-1 + σm/σs = 79.6/190 + 119.4/360
= 0.419 + 0.332 = 0.751
n_f = 1 / 0.751 = 1.33 < 1.5 ✗
Static strength passes, fatigue fails — this is the most common failure point for parts under alternating load. Although the stress amplitude σa of the fluctuating cycle is only 79.6 MPa, the fatigue limit σ-1 is only 190 MPa, so the margin is not generous.
A = π×45²/4 = 1590 mm²
σmax = 157.2 MPa, σmin = 31.4 MPa
σm = 94.3 MPa, σa = 62.9 MPa
n_s = 360 / 157.2 = 2.29 ✓
n_f = 1/(62.9/190 + 94.3/360) = 1/0.593 = 1.69 ✓
Increasing the section from φ40 to φ45 (area +26%) reduces the stress amplitude by 21% and raises the fatigue safety factor from 1.33 to 1.69, so both checks now pass.
If 40Cr quenched and tempered is used instead, keeping φ40:
n_s = 785 / 198.9 = 3.95 ✓
n_f = 1/(79.6/280 + 119.4/785)
= 1/0.436 = 2.29 ✓
The strength margin is ample and it is about 21% lighter than the φ45 option, but the material plus quenching and tempering costs about 1.9 times that of 45 steel. The trade-off rule: large batches and weight-sensitive applications (long strokes, frequent reciprocation, moving parts) → choose 40Cr φ40; cost-driven, small batches and single pieces → choose 45 steel quenched and tempered at φ45.
Final selection: 45 steel quenched and tempered (HB 217~255), rod body φ45, threaded section M42×3, transition fillet above R5 with roll strengthening.
The Baisi Technical Handbook has integrated this calculation module into the Group 0 Basic Tools calculation module. Enter the grade and the heat treatment condition, and it automatically outputs σb, σs, σ-1, E, HB and the allowable stress. Say goodbye to paging through handbooks, to hand calculations and to rule-of-thumb estimates. —— Baisi Technical Handbook download https://pan.baidu.com/s/1bquayZpfas6oYBbG0gp3Gw?pwd=2giv
| Property | Symbol / unit | Main use | Typical pattern of values |
|---|---|---|---|
| Tensile strength | σb / MPa | Judging brittle fracture, estimating the fatigue limit | Carbon steel 400~1000, alloy steel up to 1200+ |
| Yield strength | σs / MPa | The core of static strength verification for ductile materials | About 0.5~0.7 of σb |
| Fatigue limit | σ-1 / MPa | Strength verification under alternating load | Bending about 0.4~0.5σb; for tension-compression multiply by 0.7 |
| Elastic modulus | E / MPa | Stiffness, deformation and buckling calculations | Steel 2.06×10⁵, cast iron 1.2×10⁵, aluminium 0.7×10⁵ |
| Hardness | HB / HRC | Wear resistance, machinability, heat treatment criteria | 45 steel quenched and tempered 217~255HB; hardened 45~55HRC |
| Elongation / impact energy | δ / %, Akv / J | Ductility, toughness, assessment of low-temperature brittle fracture | Structural parts δ≥5%, at −20℃ Akv≥27J |
| Density | ρ / kg·m⁻³ | Weight, moment of inertia, centrifugal force | Steel 7850, cast iron 7200, aluminium 2700 |
| Parameter | Meaning |
|---|---|
| σmax / σmin | Maximum / minimum values in the working stress cycle |
| σm | Mean stress, the steady component |
| σa | Stress amplitude, the alternating component and the culprit in fatigue |
| σ-1 | Fully reversed (σm=0) fatigue limit — note whether it is bending or tension-compression |
| n_s / n_f | Static strength safety factor / fatigue safety factor |
| Grade | σb (MPa) | σs (MPa) | σ-1 bending (MPa) | HB | Relative cost |
|---|---|---|---|---|---|
| Q235B (normalised) | 400 | 235 | 170 | ≤156 | 1.0 |
| 35 steel | 530 | 315 | 220 | 156~207 | 1.2 |
| 45 steel | 650 | 360 | 275 | 217~255 | 1.4 |
| 40Cr | 980 | 785 | 400 | 241~286 | 2.6 |
| 42CrMo | 1080 | 930 | 450 | 285~320 | 3.4 |
| 20CrMnTi (carburised and hardened) | 1080 | 850 | 430 | 58~62HRC | 3.8 |
| Duty condition | n_s (static strength) | Explanation |
|---|---|---|
| Accurate load and stress calculation, reliable material | 1.2~1.5 | General mechanical parts |
| Estimated load, castings or corrosive service | 1.5~2.5 | Cranes, mining equipment |
| Important applications, serious consequences of failure | 2.5~4.0 | Lifting mechanisms, pressure vessels |
| Fatigue verification (Soderberg) | ≥1.5 | Add size/surface factors for alternating load |
| Loading mode | Relation of σ-1 to σb | Example with 45 steel (σb=650) |
|---|---|---|
| Bending | σ-1 ≈ (0.40~0.50) σb | about 275 MPa |
| Tension-compression | σ-1 ≈ 0.7 × bending value | about 190 MPa |
| Torsion | τ-1 ≈ 0.55~0.60 × bending value | about 155 MPa |
| Common error | Consequence | Correct practice |
|---|---|---|
| Looking up only σb and using it for static strength verification | Ductile materials are checked against tensile strength, so the safety factor is overstated by a factor of two | Always use σs for ductile materials; only brittle materials such as cast iron use σb |
| Using the bending fatigue limit for tension-compression | Fatigue strength overestimated by about 43%, and alternating tension-compression parts fail in batches | Take 0.7 of the bending value for tension-compression and 0.55~0.6 for torsion |
| Expecting a material change to improve stiffness | Swapping 45 steel for 40Cr leaves the deflection almost unchanged — money wasted | E of all steels is about 2.06×10⁵ MPa; stiffness can only be improved by changing the section or the structure |
| Checking only σmax and not σa in fatigue verification | Parts with a high mean stress but small amplitude are wrongly judged safe, and the reverse is missed | Separate σm and σa first, then substitute into Soderberg or Goodman |
| Looking up the table without the heat treatment condition | σs of the same grade differs by a factor of 2~3 and the verification result is completely distorted | Look up grade and condition as a pair (e.g. "45 steel, quenched and tempered") and state it in the drawing technical requirements |
One-sentence summary of the material property quick reference: first look at the failure mode to decide which figures to look up, then separate σm and σa, and finally trial-calculate with the cheap material and only upgrade when it fails. Remember three figures — static strength depends on σs, fatigue on σ-1 and stiffness on E, and E cannot be changed by changing the grade.