The speed control circuit is the “heart circuit” of a hydraulic system — throttle control is structurally simple and cheap but inefficient and hot, while volumetric control is efficient and cool but expensive. How the circuit parameters are calculated directly determines whether the system can reach the design speed and whether the heat dissipation exceeds its limit. Below we work through one inlet throttle control circuit example, then unfold the formulas and parameter tables.
Inlet throttle control circuit: cylinder cap-side area A₁ = 50 cm² = 5000 mm², rod-side area A₂ = 25 cm² = 2500 mm², load F = 20000 N, required piston speed v = 0.083 m/s (≈5 m/min).
Fixed-displacement pump supply, relief valve set pressure pp = 6.3 MPa. Find the load pressure, required flow, throttle valve differential pressure, pump flow and circuit efficiency.
The inlet chamber must build up 4 MPa to move the 20000 N load. This is the “first link” in the circuit pressure chain.
Speed × cap-side area = inlet flow. This is the flow that has to pass through the throttle valve.
The difference between the relief valve set pressure and the load pressure is the differential pressure across the throttle valve — it is this pressure that “squeezes” the flow through the orifice.
The fixed-displacement pump flow must exceed the maximum required throttle valve flow in order to make speed control possible; take qp = 40 L/min:
Those 15 L/min are the “price” of throttle control — pressurised oil is spilled back to the tank and turns into heat.
Output power 1667 W / input power 4200 W ≈ 40%. This is the typical efficiency of throttle control — simple, but it wastes 60% of the energy (turned into heat). For high-power systems, volumetric control or a combined volumetric-throttle circuit is recommended.
| Speed control method | Working principle | Efficiency | Characteristics |
|---|---|---|---|
| Throttle control | Fixed-displacement pump + throttle valve / flow control valve, relief valve holding constant pressure | Low (30~50%) | Structurally simple, low cost, high heat generation, suitable for low power |
| Volumetric control | A variable-displacement pump changes its displacement directly | High (above 80%) | No overflow loss, low heat generation, suitable for high power |
| Combined volumetric-throttle control | Variable-displacement pump + flow control valve | Medium (50~70%) | The pump flow matches automatically, combining the advantages of both |
| Arrangement | Position | Characteristics |
|---|---|---|
| Inlet throttling | The throttle valve is in the inlet line | Smooth start, but the speed varies with the load when the load changes |
| Return-line throttling | The throttle valve is in the return line | High back pressure, smooth motion, can handle negative (overrunning) loads |
| Bypass throttling | The throttle valve is in parallel with the cylinder | Lowest efficiency and poor speed stiffness, rarely used |
1. Load pressure (inlet chamber):
2. Required flow:
3. Throttle valve differential pressure:
4. Flow characteristic of the throttle valve:
5. Circuit efficiency:
| Symbol | Meaning | Unit | Value notes |
|---|---|---|---|
| F | Load force | N | Includes friction and other resistances |
| A₁, A₂ | Cap-side / rod-side area | mm² or cm² | 1 cm² = 100 mm² |
| v | Piston speed | mm/min or m/s | v = q/A |
| pp | Pump / relief valve set pressure | MPa | Take (1.2~1.3)× the maximum load pressure |
| Δp | Throttle valve differential pressure | MPa | Inlet throttling Δp = pp − p₁ |
| qp | Fixed-displacement pump flow | L/min | 30~50% greater than the maximum required flow |
| Item | Recommended value | Notes |
|---|---|---|
| Rated pump flow qp | (1.3~1.5) × qmax | qmax is the required flow at the upper limit of the speed control range |
| Relief valve set pressure pp | (1.2~1.3) × p1,max | Leaves 1~2 MPa for the throttle valve differential pressure |
| Minimum stable flow of the throttle valve | Look it up in the valve catalogue | It determines the lowest stable speed |
| Speed control method | Speed control range | Speed stiffness | Applicable power |
|---|---|---|---|
| Throttle control | Large (>100:1) | Poor (the speed swings widely with load changes) | < 3~5 kW |
| Volumetric control | Medium (~40:1) | Good (the variable-displacement pump self-compensates) | High power |
| Combined volumetric-throttle control | Fairly large | Good | Medium power, where smoothness is required |
| # | Common error | Consequence | Correct practice |
|---|---|---|---|
| 1 | Using the rod-side area for the required flow (mistaking the return stroke) | The inlet flow is calculated wrongly and the speed cannot be reached | For rapid approach and feed use the cap-side A₁, for rapid return use the rod-side A₂ |
| 2 | Sizing the pump flow exactly at the required flow with no overflow margin | The throttle valve cannot control the speed and the system builds up pressure | qp = (1.3~1.5)qmax |
| 3 | Taking the relief valve pressure equal to the load pressure with no throttle differential pressure left | The throttle valve differential pressure is insufficient and the flow cannot rise | pp = (1.2~1.3)p1,max, Δp ≥ 1 MPa |
| 4 | Using throttle control in a high-power system | Severe heat generation, excessive oil temperature and system failure | For >5 kW prefer volumetric control |
| 5 | Still using an ordinary throttle valve with a widely fluctuating load | The speed swings violently with the load | Use a flow control valve (with pressure compensation) |