Shaft torsional stiffness is assessed by the twist angle per unit length — when the twist angle grows, gear transmission falls out of synchronism, indexing and positioning lose accuracy, and torsional vibration can even be triggered. Many people check only the torsional strength (τ ≤ [τ]) and skip the torsional stiffness check entirely. Below we work through one gearbox low-speed shaft example, then unfold the formulas and the allowable value tables.
Gearbox low-speed shaft, transmitted torque T = 1200 N·m = 1.2×10⁶ N·mm, length of the twisted portion L = 400 mm, shaft diameter d = 60 mm (solid circular section), material C45 steel quenched and tempered, shear modulus G = 8.1×10⁴ MPa.
Verify that the twist angle per unit length meets the requirement for an ordinary transmission shaft.
Polar second moment of area of a solid circular shaft (note it is twice the second moment of area for bending):
Conversion: 1 rad = 57.3°, θ(°/m) = θ(rad/m) × 180/π.
For an ordinary transmission shaft the allowable twist angle is [φ] = 0.5 ~ 1.0 °/m.
The twist over the entire shaft is less than 0.3 degrees. That is no problem for an ordinary transmission, but for indexing, positioning or cam mechanisms 0.27° can already affect the accuracy, so it must be rechecked against the precision standard.
If this shaft were used in an indexing mechanism, the allowable [φ] = 0.25 ~ 0.5 °/m and the 0.67 °/m at d = 60 mm is out of limits ✗.
Increasing it to d = 70 mm: I_p = π×70⁴/32 ≈ 2.36×10⁶ mm⁴, φ = 1.2×10⁶/(8.1×10⁴×2.36×10⁶) ≈ 0.36 °/m ✓ acceptable.
Conclusion:d = 60 mm is acceptable for an ordinary transmission (utilisation 67%); for precision indexing it must be enlarged to d = 70 mm — a typical case where the torsional stiffness check determines the shaft diameter.
Shaft torsional stiffness is measured by the twist angle φ per unit length (rad/m or °/m). The consequences of insufficient stiffness are: phase shift in gear transmission, inaccurate indexing dial positioning, distorted cam profiles, torsional vibration of long shafts, and increased fretting wear at key connections. The key difference from bending stiffness is that it uses thepolar second moment of area I_p(not the second moment of area I), and I_p = 2I.
| Section shape | Polar second moment of area I_p | Notes |
|---|---|---|
| Solid circular shaft | πd⁴/32 | d is the diameter |
| Hollow circular shaft | π(D⁴−d⁴)/32 | D outer diameter, d inner diameter |
| Thin-walled circular tube | πD³t/4 (approximate) | t is the wall thickness, D is the mean diameter |
1. Twist angle per unit length:
2. Total twist angle over the whole shaft:
3. Converting radians to degrees:
| Symbol | Meaning | Unit | Value notes |
|---|---|---|---|
| T | Transmitted torque | N·mm | 1 N·m = 1000 N·mm |
| L | Length of the twisted portion | mm | Distance between the two sections that transmit the torque |
| G | Shear modulus | MPa | Steel 7.9~8.1×10⁴; cast iron 4.5×10⁴; cast steel 7.0×10⁴ |
| I_p | Polar second moment of area | mm⁴ | Solid shaft πd⁴/32 (= 2× the second moment of area for bending) |
| θ | Twist angle per unit length | rad/m or °/m | Compare with [φ] |
| φ | Total twist angle over the whole shaft | rad or ° | Check this especially for indexing and positioning applications |
| Shaft type | Allowable twist angle [φ] | Typical application |
|---|---|---|
| Precision transmission shaft, indexing shaft | 0.25 ~ 0.5 °/m | Indexing dials, cams, precision machine tools |
| Ordinary transmission shaft | 0.5 ~ 1.0 °/m | Gearbox shafts, ordinary transmission shafts |
| Shafts with low stiffness requirements | 1.0 ~ 2.5 °/m | Agitator shafts, long suspension rods (strength check governs) |
| Material | G (MPa) |
|---|---|
| Carbon steel and alloy steel (45, 40Cr) | 7.9~8.1 ×10⁴, 8.1×10⁴ commonly used |
| Cast steel (ZG270-500) | 7.0×10⁴ |
| Grey cast iron (HT250) | 4.5×10⁴ |
| # | Common error | Consequence | Correct practice |
|---|---|---|---|
| 1 | Using the bending second moment of area πd⁴/64 instead of the polar one | The twist angle is underestimated by a factor of 2 and the shaft is too slender | Torsion must use I_p = πd⁴/32 |
| 2 | Not converting the torque unit (treating N·m as N·mm) | The twist angle is computed 1000 times too small, a gross misjudgement | Use N·mm throughout: 1 N·m = 1000 N·mm |
| 3 | Using the steel value of G for a cast iron shaft | The twist angle is underestimated by nearly half | Cast iron G ≈ 4.5×10⁴ MPa |
| 4 | Using the ordinary transmission allowable value for an indexing or positioning shaft | Positioning error and phase shift | In precision applications [φ] ≤ 0.5 °/m |
| 5 | Calculating only the twist angle per unit length and ignoring the total twist over the whole shaft | The accumulated twist of a long shaft is out of tolerance | φ_total = T·L/(G·I_p), always check this for indexing applications |