MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
Knowledge Base › Bearings › How to Choose Between DB, DF a
HomeModels
Table of contents

Bearings (12 articles)

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

🛠️ Baise Technical Handbook · 500+ standard-part selection and calculation tools
Covers pneumatics, motors, power transmission, gearboxes, couplings, bearings, hydraulics, threads, worm gears and springs
Avoid 95% of design errors and raise design efficiency by 80%
Master 10 years of senior-engineering experience in 3 months
Download: https://pan.baidu.com/s/1bquayZpfas6oYBbG0gp3Gw?pwd=2giv

📖 Next issue preview: deep groove ball bearing life calculation

How to Choose Between DB, DF and DT Angular Contact Bearing Arrangements: Stiffness and Load in 6 Steps

A single row angular contact ball bearing can only carry an axial load in one direction, so in practice they must be used in pairs. The DB, DF and DT arrangements differ completely in stiffness, load capacity and permissible speed. Choose the wrong one and the result is at best excessive vibration and at worst a burned-out bearing. Below we work through the loads and stiffness of all three arrangements using a high-speed spindle case, and then expand into the selection principles.

1. Complete Worked Example

Duty condition: a high-speed spindle uses a pair of 7206C angular contact ball bearings (contact angle α = 15°, basic dynamic load rating C = 28500 N, e = 0.38). The radial loads on the bearings are Fr₁ = 1800 N and Fr₂ = 1200 N, there is an additional axial force Ka = 800 N, the speed is n = 1450 r/min, and a high axial stiffness of the support is required.

Step 1 — Determine the arrangement: choose back-to-back DB mounting

DB back-to-back mounting: the load center of the two bearings lies outside them, so the support span is large and the axial stiffness is high, which suits spindles that carry an overturning moment and require high stiffness.
By comparison: DF face-to-face mounting has a small span and lower stiffness; DT tandem can only carry an axial load in one direction and therefore does not meet the bidirectional loading requirement of this duty.
Conclusion: choose DB mounting (back-to-back).

Step 2 — Calculate the internal axial force Fs of each bearing

At α = 15° the internal axial force coefficient is e = 0.38.
Fs₁ = e × Fr₁ = 0.38 × 1800 = 684 N
Fs₂ = e × Fr₂ = 0.38 × 1200 = 456 N

Step 3 — Identify the tightened and relaxed ends

With DB mounting the two Fs act in opposite directions (back to back). Compare Fs₁ with Fs₂ + Ka:
Fs₁ = 684 N, Fs₂ + Ka = 456 + 800 = 1256 N
684 < 1256 → bearing 1 is tightened and bearing 2 is relaxed.

Step 4 — Calculate the actual axial load Fa

The relaxed end takes its own Fs, and the tightened end takes the Fs from the opposite side plus the external load:
Fa₂ (relaxed end) = Fs₂ = 456 N
Fa₁ (tightened end) = Fs₂ + Ka = 456 + 800 = 1256 N

Step 5 — Calculate the equivalent dynamic load P

Bearing 1: Fa₁/Fr₁ = 1256/1800 = 0.698 > e → X=0.44, Y=1.47
P₁ = 0.44 × 1800 + 1.47 × 1256 = 792 + 1846 = 2638 N
Bearing 2: Fa₂/Fr₂ = 456/1200 = 0.38 ≤ e → X=1, Y=0
P₂ = 1 × 1200 + 0 × 456 = 1200 N
P₁ = 2638 N is used as the basis for the life calculation.

Step 6 — Comparison: what if DT tandem were used instead?

DT tandem carries an axial load in one direction only (this duty is loaded in both directions, so it cannot be chosen). If designed for one direction only, the basic dynamic load rating of two identical bearings in tandem is:
C combination = n^0.7 × C = 2^0.7 × 28500 = 1.62 × 28500 ≈ 46200 N
The axial load capacity improves by about 62%, but it can only carry an axial load in one direction and another support point is needed for fixation.
Final selection: DB mounting (back-to-back), P₁ = 2638 N, with the life verified using the formula from article 050.

🛠️ Baise Technical Handbook · Connection and Shafting Calculation Module
The Baise Technical Handbook has integrated this calculation module into its connection and shafting calculation module. Enter the duty condition parameters and the selection result is output automatically. Say goodbye to flipping through handbooks, to hand calculations and to rule-of-thumb estimating. —— Baise Technical Handbook download address https://pan.baidu.com/s/1bquayZpfas6oYBbG0gp3Gw?pwd=2giv

2. The Three Arrangement Schemes: How to Tell DB, DF and DT Apart

The three ways of using angular contact ball bearings in pairs differ essentially in the relative position of the load center (pressure center):

ArrangementLayoutPressure centerAxial stiffnessCharacteristics
DB back-to-backWide end face to wide end face (back to back)Outside the two bearingsHighLarge support span, strong resistance to overturning moment, suited to spindles and grinding heads
DF face-to-faceNarrow end face to narrow end face (face to face)Between the two bearingsRelatively lowSmall span, compact structure, easy to adjust clearance, suited to short shafts and gear shafts
DT tandemSide by side in the same direction (one facing left, one facing left)Offset to one side—Carries an axial load in one direction only, with a high combined load capacity, and requires a spring preload
Memory aid:the second letter stands for the force direction — the "B" in DB is Back, the "F" in DF is Face, and the "T" in DT is Tandem. Back-to-back gives the greatest stiffness.

3. Core Calculation Formulas

1. Internal axial force Fs

Fs = e × Fr (e≈0.38 for α=15°; e≈0.68 for α=25°; e≈1.14 for α=40°)

2. Identifying the tightened and relaxed ends

Fs₁ ?= Fs₂ + Ka
If Fs₁ < Fs₂ + Ka → bearing 1 is tightened; otherwise bearing 2 is tightened

The relaxed bearing takes its own Fs, and the tightened bearing takes the Fs from the other side plus the external axial force.

3. Equivalent dynamic load P

P = X·Fr + Y·Fa

4. Basic dynamic load rating of a DT tandem combination

C combination = n^0.7 × C (n is the number of bearings in tandem)
Number in tandem n1234
n^0.7 coefficient1.001.622.162.64

4. Arrangement Selection Guide

ApplicationRecommended arrangementReason
Machine tool spindles, grinding heads, high-speed spindlesDBHigh stiffness, good resistance to overturning, suits high-speed heavy loading
Short shafts, gear shafts, fan bearing housingsDFCompact structure, easy to adjust the clearance and the preload
Shafts with a unidirectional heavy axial load (such as the driving shaft of a screw helical gear)DT (plus another support point for fixation)High combined load capacity, definite axial force direction
Long shafts needing thermal expansion compensationDB or DF with one end floatingA deep groove ball bearing at the other end serves as the floating support
Selection key points:① With bidirectional axial loading you must use DB or DF; ② When only a unidirectional axial load is carried and it is very large, use DT; ③ In high-speed applications prefer DB for the higher stiffness; ④ When the installation space is restricted and the shaft is short, use DF; ⑤ Whatever the arrangement, control the axial clearance and avoid excessive preload heating.

5. Common Mistakes and How to Avoid Them

Common mistakeConsequenceCorrect practice
Installing DB as DF (or the other way round) without following the drawing orientationA sudden change in stiffness, spindle vibration and high noiseCheck the mounting direction against the wide and narrow outer ring end face identification
Choosing DT tandem for a bidirectionally loaded dutyUnder reverse loading the bearings pull out axially and fail instantlyBidirectional loading requires a DB or DF pair
Calculating the life of a DB/DF combination as if it were a single row bearingThe load is wrong and the life deviates badlyTake the opposite Fs + Ka on the tightened end, compute P for each bearing and use the larger
Treating the load capacity of a tandem combination as a simple sumThe actual load capacity is overestimatedCalculate it as C combination = n^0.7 × C
Ignoring the preload and clearance adjustmentExcessive preload heats the bearing and burns it, while excessive clearance causes vibrationFollow the manufacturer's recommended preload class and axial clearance range
Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL