E44-499 · Filter Blockage and Fouling · Vacuum Cleaner Filter Nonwoven · ★★
Media loaded with dust, breathability drops, suction down 40%, cleaning ineffective
[Mechanism] Fine dust embeds in pores, lowering breathability.
[Calculation] Dust loading lowers α by 50%, Δp rises at the same airflow, suction drops 40%.
[Design Omission] No dust shaking and unsuitable material; breathability drops.
1) Add automatic dust shaking to restore breathability, because the original α drop of 50%, 40% suction loss and ineffective cleaning caused the problem, so shaking restores suction;
2) Change to washable media to restore breathability, because embedded dust persists, so washable media is used;
3) Set a suction alarm, because reduced flow means weak suction, so an alarm is provided;
4) Pre-collect large debris at the inlet, because large debris occupies capacity, so pre-collection is used;
5) Upsize the dust bag capacity, because small bags fill frequently, so larger capacity is used;
6) Wash the media regularly, because buildup grows gradually, so scheduled washing is used;
7) Seal the air duct to hold pressure, because internal leakage weakens suction, so sealing is used;
8) Write dust shaking and media washing into the vacuum-cleaner specification, because the lack of shaking was the root cause of the drop, so the vacuum spec governs.
GB/T 14295-2019 Air filters