E44-500 · Filter Blockage and Fouling · Spray-Dryer Exhaust Filter · ★★
Hot humid air meets cold surfaces and condenses, blinding the bag, airflow drops, tower pressure abnormal
[Mechanism] Dew point is reached and condensation sticks to the bag.
[Calculation] Wall temperature < dew point causes condensation, α drops 40%, airflow drops 25%.
[Design Omission] No insulation and no hot-air tracing; blinding results.
1) Insulate the filter housing so wall temperature > dew point, because the original wall < dew point, condensation, 40% α drop and 25% airflow drop caused the blinding, so insulation prevents blinding;
2) Hot-air trace the inlet to prevent condensation, because cold causes condensation, so hot-air tracing is used;
3) Strengthen pulse cleaning to release dust, because sticky dust adheres, so stronger cleaning is used;
4) Set an airflow alarm, because reduced flow means abnormality, so an alarm is provided;
5) Change to anti-stick media, because the original media sticks easily, so anti-stick media is used;
6) Monitor dew point, because exceeding it causes condensation, so dew point is monitored;
7) Pulse regularly to prevent buildup, because buildup blinds it, so regular pulsing is used;
8) Write insulation and heat tracing into the dryer specification, because the lack of insulation was the root cause of blinding, so the dryer spec governs.
GB/T 14295-2019 Air filters