E44-501 · Filter Blockage and Fouling · Ink Filter 100 Mesh · ★★
Pigment agglomerates clog the mesh, ink supply cuts out, print color uneven, waste sheets
[Mechanism] Flocculated pigment agglomerates lodge in the mesh.
[Calculation] Agglomerate d=200μm exceeds the 150μm mesh opening, 40% of openings bridged, supply Q drops.
[Design Omission] No dispersant and no frequent cleaning; blockage results.
1) Add dispersant to the ink to prevent flocculation, because the original agglomerates d=200 exceeding 150, 40% bridging and flow cutout caused the blockage, so dispersion keeps supply flowing;
2) Make the quick-release mesh washable each shift, because buildup blocks it, so frequent washing is used;
3) Pre-screen before printing to remove agglomerates, because clumps lodge, so pre-screening is used;
4) Stabilize supply pressure to prevent pulse cutout, because pulsing cuts ink flow, so pressure is stabilized;
5) Use dual fine filters upstream of the gun, because a single filter can pass debris, so dual filtration is used;
6) Control ink viscosity to prevent thickening, because thick ink lodges, so viscosity is controlled;
7) Recirculate through the filter to prevent settling, because settling blocks it, so recirculated filtration is used;
8) Write dispersion and mesh washing into the printing specification, because the lack of dispersion was the root cause of blockage, so the printing spec governs.
GB/T 26114-2010 Liquid filters - Filters for filtration