E44-502 · Filter Blockage and Fouling · Fermenter Air Filter 0.2μm · ★★★
Steam sterilization incomplete, filter element carries bacteria, fermentation contaminated, whole batch wasted
[Mechanism] Sterilization dead corners leave bacteria surviving.
[Calculation] Sterilization F0 <8 leaves residual bacteria, breakthrough, contamination rate rises, whole batch wasted.
[Design Omission] F0 not maintained and dead corners present; sterilization incomplete.
1) Maintain F0≥15 during sterilization with no dead corners, because the original F0<8, residual bacteria and contamination caused the failure, so adequate F0 sterilizes completely;
2) Use steam-wet-sterilizable elements, because dry baking damages them, so wet sterilization is used;
3) Perform integrity testing before and after sterilization, because installation can also damage the element, so integrity is tested;
4) Sterility-monitor the outlet, because contamination becomes detectable, so monitoring is provided;
5) Ensure adequate steam dryness to prevent cold spots, because cold leaves survivors, so sufficient dryness is used;
6) Design piping dead-leg free to prevent harboring, because dead legs harbor bacteria, so dead-leg-free design is used;
7) Keep batch records for traceability, because fermentation requires traceability, so traceability is maintained;
8) Write F0 into the fermentation specification, because the lack of maintenance was the root cause of contamination, so the fermentation spec governs.
GB/T 13554-2020 High-efficiency air filters