MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
HomeModels
Table of contents

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

Knowledge Base › Fluid Systems Error Case › Filter Mesh Too Fine Blockage

Filter Mesh Too Fine Blockage

E44-1055 · Filter Blockage and Fouling · Filter Mesh · ★★

Problem Description

Mesh too fine, blocked, pressure drop

Root Cause

[Mechanism] The mesh is too fine with insufficient open area, so impurities in the medium rapidly bridge and block it, and the differential pressure spikes.
[Calculation] 200 mesh selected (40 mesh appropriate), open area 18%, v=4m/s, ΔP=0.4MPa exceeds the 0.15 alarm, fully blocked in 3 days, flow drops 40%.
[Design Omission] Wrong mesh size selected, mesh resistance not checked, no bypass provided.

Corrective Solution

1) Switch to a 40-mesh screen (45% open area), because the fine mesh caused blockage and a coarser screen restores flow, so flow is restored;
2) Check mesh resistance (design ΔP≤0.1MPa), because high resistance drops flow and checking it protects flow, so flow is stable;
3) Increase pump pressure margin (keep 20% spare), because low pressure causes drop and added margin stabilizes, so resistance to blockage is improved;
4) Provide a bypass (automatic on blockage), because blockage cuts flow and the bypass protects it, so flow is not interrupted;
5) Run a resistance test (measured ΔP≤0.1MPa), because blockage was not checked and measurement confirms flow, so resistance is set by data;
6) Install a differential gauge plus alarm (alarm at ΔP>0.15MPa), because blockage first shows as differential pressure and early notice helps, so blockage is monitored and warned;
7) Keep the medium clean in operation (upstream coarse strainer), because many impurities cause blockage and cleanliness eases it, so operational blockage prevention is applied;
8) Write mesh selection and resistance check into the specification, because the root cause of fine-mesh blockage was selecting too small a mesh and not checking resistance, so the specification governs.

Checklist

Reference

HG/T 21637-1991 Chemical-industry piping filters

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL