E44-1056 · Filter Blockage and Fouling · Filter · ★★
No bypass, blockage shutdown, flow interruption
[Mechanism] The filter has no bypass; once blocked, flow cuts out and downstream equipment loses feed.
[Calculation] DN150 filter, 70% blocked, downstream Q drops from 100 to 5m³/h, pump runs dry, feed interrupted for 2h.
[Design Omission] No bypass, bypass bore not checked, no differential-pressure monitoring.
1) Add a bypass line (same DN150 size), because blockage cuts flow and the bypass protects it, so flow is not interrupted;
2) Verify bypass capacity (≥100% flow), because a small bore causes interruption and checking the bore protects it, so full flow is ensured;
3) Set a differential-pressure alarm (switch at ΔP>0.12MPa), because blockage cuts flow and the alarm switches in the bypass, so the bypass is engaged in time;
4) Increase screen capacity (larger debris chamber), because small capacity causes blockage and added capacity eases it, so resistance to blockage improves;
5) Run a flow test (bypass Q≥100 when blocked), because interruption was not checked and measurement ensures it, so flow capacity is set by data;
6) Install flow monitoring (alarm on flow interruption), because interruption first shows as flow drop and early notice helps, so interruption is monitored and warned;
7) Control the switching interval in operation (check differential pressure weekly), because long operation causes blockage and controlled timing engages the bypass, so operational interruption prevention is applied;
8) Write bypass provision and bore check into the calculation sheet, because the root cause of no bypass was omission and an unchecked bore, so the calculation sheet governs.
HG/T 21637-1991 Chemical-industry piping filters