Insufficient Straight Pipe Downstream of the Valve Vibration

E44-866 · Throttling Noise and Vibration · Pipe downstream of valve · ★★★

Problem Description

Only 3D of straight pipe downstream of the valve distorted the flow field, vibrating the pipe by 0.5mm

Root Cause

[Mechanism] Insufficient straight pipe downstream of the valve leaves the distorted flow field unrecovered; the biased flow strikes the pipe wall and causes vibration.
[Calculation] A straight pipe of ≥10D is needed to recover the flow field; the original 3D made the vortices strong and the amplitude 0.5mm.
[Design Omission] No long straight pipe, no section-length verification, no flow-straightening grid.

Corrective Solution

1) Keep a straight pipe section (≥10D downstream of the valve to recover the flow field), since the original 3D distorted the flow and vibrated the pipe by 0.5mm, thus keeping it long steadies the flow;
2) Verify the section length (≥10D, or a straightener for an equivalent effect), since short vibrates and verification makes it sufficient, thus the section length;
3) Add supports (pipe clamp spacing ≤3m), since sway vibrates and support steadies it, thus supporting;
4) Add a flow-straightening grid (a straightening grid downstream of the valve to remove distortion), since disorder vibrates and the grid evens it out, thus the straightening grid;
5) Monitor the vibration (measure the amplitude, alarm >0.3mm), since gradual vibration approaches cracking and early detection catches it, thus monitoring vibration;
6) Run a vibration test (measure the frequency response), since the lack of testing left the vibration undetected and the test reveals the level, thus testing vibration;
7) Control the flow to steady the speed (limit v), since changing conditions increase distortion and steadying controls it, thus controlling speed;
8) Write the long straight pipe and section verification into the calculation sheet, since the original lack of length is the root cause of shortness and locking it in closes the loop, thus controlling it in the calculation.

Checklist

Reference

GB/T 20801.3-2020 Design code for industrial metallic piping

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL