Knowledge Base › Fluid Systems Error Case › Vibration from Throttling Flashing

Vibration from Throttling Flashing

E44-867 · Throttling Noise and Vibration · Throttling element · ★★★

Problem Description

A saturated liquid at the inlet flashed at the outlet, vibrating the valve stem by 0.7mm

Root Cause

[Mechanism] Throttling drops the pressure below the saturation pressure and the liquid flashes into a vapor-liquid two-phase flow; the phase change impact causes vibration.
[Calculation] Outlet p2<pv, the two-phase density difference is large, and the pulsating force vibrates the valve stem by 0.7mm.
[Design Omission] No flashing avoidance, no outlet-pressure verification, no cavitation-resistant trim.

Corrective Solution

1) Avoid flashing (raise the outlet pressure above pv, or move the valve to a subcooled section), since the original p2<pv flashing vibrated the valve stem by 0.7mm, thus avoiding flashing prevents vibration;
2) Verify the outlet pressure (p2≥pv+0.05), since low pressure vibrates and verification avoids it, thus verifying pressure;
3) Replace with cavitation-resistant trim (tungsten carbide), since two-phase erosion vibrates and the replacement resists it, thus replacing the trim;
4) Use multi-stage reduction (3 stages), since concentration vibrates and splitting eases it, thus staging;
5) Monitor the vibration (measure the stem amplitude, alarm >0.3mm), since gradual vibration approaches cracking and early detection catches it, thus monitoring vibration;
6) Run a vibration test (measure the frequency response), since the lack of testing left the vibration undetected and the test reveals the level, thus testing vibration;
7) Control the temperature to prevent flashing (lower the inlet temperature to subcool), since heat flashes and control cools, thus controlling temperature;
8) Write the flashing avoidance and pressure verification into the calculation sheet, since the original lack of avoidance is the root cause of vibration and locking it in closes the loop, thus controlling it in the calculation.

Checklist