MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
HomeModels
Table of contents

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

Knowledge Base › Fluid Systems Error Case › Pipe Vibration from Cavitation

Pipe Vibration from Cavitation

E44-868 · Throttling Noise and Vibration · Pipe section · ★★★

Problem Description

Cavitation downstream of the orifice plate vibrated the pipe by 0.6mm and thinned the wall

Root Cause

[Mechanism] Cavitation downstream of the orifice plate collapses and strikes the pipe wall; the periodic impulse excites pipe vibration and thins the wall.
[Calculation] Cavitation number σ<1.0, collapse impact >1000MPa, pipe vibration 0.6mm.
[Design Omission] No backpressure increase, no σ verification, no supports.

Corrective Solution

1) Raise the backpressure to prevent cavitation vibration (raise p2 downstream of the orifice plate so σ≥1.3), since the original σ<1.0 cavitation vibrated the pipe by 0.6mm, thus raising pressure prevents vibration;
2) Verify σ (margin ≥1.3), since low pressure vibrates and verification avoids it, thus verifying σ;
3) Replace with a cavitation-resistant valve (carbide), since weak vibrates and the replacement resists it, thus replacing the valve;
4) Add supports (denser supports for the pipe section), since sway vibrates and support steadies it, thus supporting;
5) Monitor the vibration (measure the pipe amplitude, alarm >0.3mm), since gradual vibration approaches thinning and early detection catches it, thus monitoring vibration;
6) Run a vibration test (measure the frequency response + wall thickness), since the lack of testing left the vibration undetected and the test reveals the level, thus testing vibration;
7) Control and split the pressure drop (multi-stage, single stage Δp≤0.3MPa), since concentration vibrates and splitting eases it, thus controlling the drop;
8) Write the backpressure increase and σ verification into the calculation sheet, since the original lack of increase is the root cause of vibration and locking it in closes the loop, thus controlling it in the calculation.

Checklist

Reference

GB/T 17213.1-2015 Industrial-process control valves

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL